Nabertherm ribbed Plate, Ceramic for L..9
• Tmax 1200 °C
• Dimensions 240 x 220 x 12.7 mm
• For models L 9, LT 9, LV 9, LVT 9, N 7
Compare
%
Esco Drawer Rack
For standard 2-inch High Boxes for UUS-363/480/597/714 Model with 5 Inner Doors Configuration
• Rack Dimension (WxDxH): 139x551x228mm
• Can fit standard 130 x 130 x 50 mm (5.25” x 5.25” x 2”) boxes
• Has 4 shelves and contain 4 boxes per shelf. (4 x 4 configuration)
• Made of stainless steel and has handles.
• Weight: 5 Kg
Compare
%
Ohaus Rotor, Angle, 30x15ml RB/FA, ID
Frontier rotors extend the functionality of Frontier centrifuges by increasing the number of tubes of varied types and sizes that can be used in conjunction with each of the centrifuge models. Easy to clean and operate, the rotors are durably constructed to withstand demanding centrifugation.
Compatible adapters and other accessories:
• Adapter, D11mm, 1.5/2.0ml Tubes x6 (30130886); Adapter, D13.5mm, 5ml Tubes x2 (30130890); Adapter, D13.5mm, 7ml Tubes x2 (30130889)
Compare
%
Miele APLW 018 upper basket
Upper basket with 121 + 24 unoccupied injector slots.
• Area of application: reprocessing laboratory glassware
• Only suitable for use on upper levels
Machine affiliation: Can be used for PLW 6111 devices.
Compare
%
Miele A 302/3 module
For optimum loading of laboratory glassware – can be equipped with 32 nozzles.
• Area of application: reprocessing laboratory glassware
• Suitable for lab. glassware incl. Erlenmeyer and round flasks.
• Equipped with 16 A 844 nozzles and 16 A 845 nozzles
Size of A 844 injector nozzle:– Ø 2.5 mm, height 80 mm
Size of A 845 injector nozzle:– Ø 2.5 mm, height 125 mm
• Part of the EasyLoad system. The EasyLoad system makes reprocessing laboratory glassware considerably faster, simpler and more reliable. The biggest benefit afforded by the new system is that load items can be positioned over nozzles both more simply and faster as height adjustment of the holders is no longer necessary thanks to the smart combination of nozzles and holding frames. This makes correct positioning extremely easy.
• Nozzle spacing 60 mm across the width, 57 mm across the depth
Machine affiliation:
PLW 8636 [LAB / LAB MON]
PG 8504
PG 8583
PG 8583 CD
PG 8593
PLW 7111
PLW 8604
PLW 8683
PLW 8683 CD
PLW 8693
Compare
%
Julabo PRESTO W85 Highly dynamic temperature control system
Advanced control technology and a small bath fluid reservoir enable highly dynamic temperature control systems to achieve rapid heat-up and cool-down. This gives you the ability to handle difficult temperature challenges quickly.
The PRESTO® systems are designed for precise temperature control as well as rapid temperature changes, making them ideal for reactor vessels, material stress tests, or temperature simulations. These instruments cover a working temperature of -92 to +250 °C with high cooling and heating capacity.
• USB connection
• For highly precise, external temperature applications
• Rapid heating and cooling
• Wide working temperature ranges without changing fluids
• Highest performance with small footprint
• Space-saving design optimizes space utilization in your lab
• Ethernet interface
• SD-Card slot
• RS232 / RS485 (optional) / Profibus DP (optional)
• Connections for alarm-output, Pt100 external sensor and standby-input
• Removable ventilation grid
• Highly precise ICC cascade temperature control
• Electronic level indication
• Integrated programmer
• Unsurpassed power and efficiency
• Space optimized design creates more room directly next to the units
• External Pt100 sensor connection
Compare
%
Miele A 303 module
For the optimum loading of up to 98 pipettes.
• Area of application: reprocessing pipettes/vials
• Suitable for 98 measuring and full pipettes, for example
• Height of holding frame 150 mm
• 1 unit can be inserted into each of the baskets A 150 and APLW 106
• Vertical clearance without upper basket: 450 mm (with A 150 lower basket)
Machine affiliation:
PLW 8636 [LAB / LAB MON]
PG 8583
PG 8583 CD
PG 8593
PLW 7111
PLW 8604
PLW 8683
PLW 8683 CD
PLW 8693
Compare
%
Miele A 304 module
For the optimum loading of up to 98 vials.
• Area of application: reprocessing pipettes/vials
• Suitable for 98 centrifuge tubes, phials, test tubes, for example
• The loading heights differ depending on the positioning
Loading height:
Loading height in lower basket without upper basket 428 mm, in lower basket with upper basket 172 mm, in upper basket 172 mm.
• 1 unit can be inserted into each of the baskets A 100, A 150 and APLW 106
Machine affiliation:
PLW 8636 [LAB / LAB MON]
PG 8504
PG 8583
PG 8583 CD
PG 8593
PLW 7111
PLW 8604
PLW 8683
PLW 8683 CD
PLW 8693
Compare
%
Miele A 306/1 module
Module for the optimum loading of large-volume laboratory glassware.
• Suitable for 4 1–2 litre measuring cylinders, high shape
• Suitable for 2 1–2 litre measuring cyl., low shape & 2 high shape
• Plastic-coated contact surfaces
• Measuring cylinders even removable when module is in machine
• Maximum length of measuring cylinders: 500 mm
• Up to 2 modules can be inserted in the baskets A 150 and APLW 106 ( it is not possible to use an upper basket at the same time).
Machine affiliation:
PLW 8636 [LAB / LAB MON]
PG 8583
PG 8583 CD
PG 8593
PLW 7111
PLW 8604
PLW 8683
PLW 8683 CD
PLW 8693
Compare
%
Miele A 312 module
Module For reprocessing viscometers.
• Suitable for up to 8 viscometers
• Equipped with 8 x A 867 special nozzles
• Nozzle spacing 118 mm across the width, 118 mm across the depth
Machine affiliation:
PLW 8636 [LAB / LAB MON]
PG 8583
PG 8583 CD
PG 8593
PLW 7111
PLW 8604
PLW 8683
PLW 8683 CD
PLW 8693
Compare
%
Nabertherm L 9/11/B510 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.
Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type N (1100 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With flap door (L)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation B510 (5 programs with each 4 segments)
• Solid state relays provide for lownoise operation
Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door
Compare
%
Kühner Tray with fixed clamps EX-200
Tray with fixed clamps EX-200 To load 27 x 200 ml Erlenmeyer flasks
Compare
%
Nabertherm collecting Pan, Ceramic for L..3
• Tmax 1300 °C
• Dimensions 150 x 140 x 20 mm
• For models L 3, LT 3, LV 3, LVT 3
Compare
%
Esco Drawer Rack
For standard 3-inch High Boxes for UUS-363/480/597/714 Model with 5 Inner Doors Configuration
• Rack Dimension (WxDxH): 139x551x245mm
• Can fit standard 130 x 130 x 80 mm (5.25” x 5.25” x 3”) boxes
• Has 3 shelves and contain 4 boxes per shelf. (3 x 4 configuration)
• Made of stainless steel and has handles.
• Weight: 4 Kg
Compare
%
Ohaus Rotor, Angle, 20x10ml RB, ID, Hi
Frontier rotors extend the functionality of Frontier centrifuges by increasing the number of tubes of varied types and sizes that can be used in conjunction with each of the centrifuge models. Easy to clean and operate, the rotors are durably constructed to withstand demanding centrifugation.
Compatible adapters and other accessories:
• No adapters
Compare
%
Miele APLW 018/1 upper basket
Upper basket equipped with 121 APLW 048 injector nozzles and 24 APLW 051 injector nozzles.
• Area of application: reprocessing laboratory glassware
• Only suitable for use on upper levels
Machine affiliation: Can be used for PLW 6111 devices.
Compare
%
Miele A 313 module
For reprocessing large-volume laboratory glassware.
• Area of application: reprocessing laboratory glassware
• Laboratory flasks, up to 10 l
• Round flasks, up to 6 l
• Erlenmeyer flasks, up to 5 l
• Measuring flasks, up to 5 l
• Can be equipped with nozzles & holders based on individual needs. (The maximum diameter of the load depends on the number of nozzles used. Depending on the load, the following nozzles are required: A 846, A 847, A 848)
• Equipped with 5 injector positions for 2 or 3 load items
Machine affiliation:
PLW 8636 [LAB / LAB MON]
PG 8504
PG 8583
PG 8583 CD
PG 8593
PLW 7111
PLW 8604
PLW 8683
PLW 8683 CD
PLW 8693
Compare
%
Julabo PRESTO A85t Highly dynamic temperature control system
Advanced control technology and a small bath fluid reservoir enable highly dynamic temperature control systems to achieve rapid heat-up and cool-down. This gives you the ability to handle difficult temperature challenges quickly.
The PRESTO® systems are designed for precise temperature control as well as rapid temperature changes, making them ideal for reactor vessels, material stress tests, or temperature simulations. These instruments cover a working temperature of -92 to +250 °C with high cooling and heating capacity.
• USB connection
• For highly precise, external temperature applications
• Rapid heating and cooling
• Wide working temperature ranges without changing fluids
• Highest performance with small footprint
• Space-saving design optimizes space utilization in your lab
• Ethernet interface
• SD-Card slot
• RS232 / RS485 (optional) / Profibus DP (optional)
• Connections for alarm-output, Pt100 external sensor and standby-input
• Removable ventilation grid
• Highly precise ICC cascade temperature control
• Electronic level indication
• Integrated programmer
• Unsurpassed power and efficiency
• Space optimized design creates more room directly next to the units
• External Pt100 sensor connection
Compare
%
Miele A 605 module
Module for optimum reprocessing of vials and test tubes, etc.
• Equipped with 98 injector nozzles
• Max. H 160 mm, max. Ø 20 mm
• For use in A 503 mobile unit
Machine affiliation:
PLW 8615
PLW 8616
PLW 8617
Compare
%
Miele A 606 module
Module for the use of e.g. lab glassware inserts on the top level of A 503 mobile units.
• Area of application: reprocessing laboratory glassware
• With spray arm
Machine affiliation:
PLW 8615
PLW 8616
PLW 8617
Compare