All products
%
Miele A 303 module
For the optimum loading of up to 98 pipettes.
• Area of application: reprocessing pipettes/vials
• Suitable for 98 measuring and full pipettes, for example
• Height of holding frame 150 mm
• 1 unit can be inserted into each of the baskets A 150 and APLW 106
• Vertical clearance without upper basket: 450 mm (with A 150 lower basket)
Machine affiliation:
PLW 8636 [LAB / LAB MON]
PG 8583
PG 8583 CD
PG 8593
PLW 7111
PLW 8604
PLW 8683
PLW 8683 CD
PLW 8693
Compare
%
Julabo CORIO CP-BC12 Heating circulator
In addition to the advantages of the CORIO C Circulator, the CORIO CD and CP
Immersion Circulator can be equipped with an optional pump set for
temperature control of external applications.
Your advantages
• Models for internal and external applications
• Bright, white, easy to read display
• Very quiet
• Easy switching between internal and external circulation
• Powerful and infinitely adjustable pressure pump
• USB connection
• RS232 interface for online communication
• High-quality bath tanks made of stainless steel with bath lid and drain tap
• Integrated pump connection M16×1
• Integrated cooling coil for counter-cooling
• Precise temperature control
• Easy pump change-over between internal and external circulatio
Compare
%
Miele A 304 module
For the optimum loading of up to 98 vials.
• Area of application: reprocessing pipettes/vials
• Suitable for 98 centrifuge tubes, phials, test tubes, for example
• The loading heights differ depending on the positioning
Loading height:
Loading height in lower basket without upper basket 428 mm, in lower basket with upper basket 172 mm, in upper basket 172 mm.
• 1 unit can be inserted into each of the baskets A 100, A 150 and APLW 106
Machine affiliation:
PLW 8636 [LAB / LAB MON]
PG 8504
PG 8583
PG 8583 CD
PG 8593
PLW 7111
PLW 8604
PLW 8683
PLW 8683 CD
PLW 8693
Compare
%
Julabo CORIO CP-BC26 Heating circulator
In addition to the advantages of the CORIO C Circulator, the CORIO CD and CP
Immersion Circulator can be equipped with an optional pump set for
temperature control of external applications.
Your advantages
• Models for internal and external applications
• Bright, white, easy to read display
• Very quiet
• Easy switching between internal and external circulation
• Powerful and infinitely adjustable pressure pump
• USB connection
• RS232 interface for online communication
• High-quality bath tanks made of stainless steel with bath lid and drain tap
• Integrated pump connection M16×1
• Integrated cooling coil for counter-cooling
• Precise temperature control
• Easy pump change-over between internal and external circulatio
Compare
%
Miele A 306/1 module
Module for the optimum loading of large-volume laboratory glassware.
• Suitable for 4 1–2 litre measuring cylinders, high shape
• Suitable for 2 1–2 litre measuring cyl., low shape & 2 high shape
• Plastic-coated contact surfaces
• Measuring cylinders even removable when module is in machine
• Maximum length of measuring cylinders: 500 mm
• Up to 2 modules can be inserted in the baskets A 150 and APLW 106 ( it is not possible to use an upper basket at the same time).
Machine affiliation:
PLW 8636 [LAB / LAB MON]
PG 8583
PG 8583 CD
PG 8593
PLW 7111
PLW 8604
PLW 8683
PLW 8683 CD
PLW 8693
Compare
%
Julabo DYNEO DD-BC4 Heating circulator
DYNEO DD heating circulators for internal and external applications are equipped with closed bath tanks. The tanks are well insulated and include a coil for counter-cooling. An integrated drain tap makes emptying the tank safe and clean. The multilingual 3.5-inch color display and unique rotary knob provide for straightforward and intuitive operation.
Optional analog and digital interface
DYNEO thermostats can optionally be equipped with analogue and digital interfaces. To request the options, order number must be extended with .d for the digital and .a for the analog interface (9XXX XXXX.A / 9XXX XXX.D)
Your advantages
• For internal and external applications
• USB connection
• Powerful and infinitely adjustable pressure pump
• Flow rate 27 l/min, pressure 0.7 bar
• Easy switching between internal and external circulation
• Large color TFT display, multilingual interface
• Central rotary knob (controller) simplifies operation
• Integrated programmer for 8 x 60 program steps
• Integrated external Pt100 connection
• RS232 interface or analog interfaces (optional)
• Bath cover included with delivery
• For internal and external applications
• High-quality thermal insulation of the bath tank
• Integrated programmer
• Integrated drain makes emptying liquid easy and safe.
Compare
%
Miele A 312 module
Module For reprocessing viscometers.
• Suitable for up to 8 viscometers
• Equipped with 8 x A 867 special nozzles
• Nozzle spacing 118 mm across the width, 118 mm across the depth
Machine affiliation:
PLW 8636 [LAB / LAB MON]
PG 8583
PG 8583 CD
PG 8593
PLW 7111
PLW 8604
PLW 8683
PLW 8683 CD
PLW 8693
Compare
%
Nabertherm L 9/11/B510 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.
Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type N (1100 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With flap door (L)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation B510 (5 programs with each 4 segments)
• Solid state relays provide for lownoise operation
Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door
Compare
%
Kühner Tray with fixed clamps EX-200
Tray with fixed clamps EX-200 To load 27 x 200 ml Erlenmeyer flasks
Compare
%
Nabertherm collecting Pan, Ceramic for L..3
• Tmax 1300 °C
• Dimensions 150 x 140 x 20 mm
• For models L 3, LT 3, LV 3, LVT 3
Compare
%
Esco Drawer Rack
For standard 3-inch High Boxes for UUS-363/480/597/714 Model with 5 Inner Doors Configuration
• Rack Dimension (WxDxH): 139x551x245mm
• Can fit standard 130 x 130 x 80 mm (5.25” x 5.25” x 3”) boxes
• Has 3 shelves and contain 4 boxes per shelf. (3 x 4 configuration)
• Made of stainless steel and has handles.
• Weight: 4 Kg
Compare
%
Ohaus Rotor, Angle, 20x10ml RB, ID, Hi
Frontier rotors extend the functionality of Frontier centrifuges by increasing the number of tubes of varied types and sizes that can be used in conjunction with each of the centrifuge models. Easy to clean and operate, the rotors are durably constructed to withstand demanding centrifugation.
Compatible adapters and other accessories:
• No adapters
Compare
%
Miele A 313 module
For reprocessing large-volume laboratory glassware.
• Area of application: reprocessing laboratory glassware
• Laboratory flasks, up to 10 l
• Round flasks, up to 6 l
• Erlenmeyer flasks, up to 5 l
• Measuring flasks, up to 5 l
• Can be equipped with nozzles & holders based on individual needs. (The maximum diameter of the load depends on the number of nozzles used. Depending on the load, the following nozzles are required: A 846, A 847, A 848)
• Equipped with 5 injector positions for 2 or 3 load items
Machine affiliation:
PLW 8636 [LAB / LAB MON]
PG 8504
PG 8583
PG 8583 CD
PG 8593
PLW 7111
PLW 8604
PLW 8683
PLW 8683 CD
PLW 8693
Compare
%
Vacuubrand VARIO® chemistry diaphragm pump MZ 2C VARIO select
The MZ 2C VARIO select pump is an excellent solution for labs working with most common solvents. The integrated VACUU•SELECT controller provides an easy-to-use, application based interface that covers all common lab applications. The VACUU•SELECT controller has you covered. Use manual set-point-control for simple processes, run fully automated distillations, or create your own application with simple drag-and-drop editing. For solvent evaporation, the VACUU•SELECT controller detects the boiling pressure and automatically adjusts the pump to maintain process control. On-demand motor speed control yields not only improved vacuum control, but it also results in unparalleled service intervals for wear parts like diaphragms and valves.
Performance features
• VACUU•SELECT vacuum controller with graphical user interface and predefined applications simplifies work in the laboratory
• automatic boiling point detection and adjustment of the vacuum for short process times
• extraordinary diaphragm life for minimum operational and servicing costs
• excellent chemical resistance
Compare
%
Julabo PRESTO A85t Highly dynamic temperature control system
Advanced control technology and a small bath fluid reservoir enable highly dynamic temperature control systems to achieve rapid heat-up and cool-down. This gives you the ability to handle difficult temperature challenges quickly.
The PRESTO® systems are designed for precise temperature control as well as rapid temperature changes, making them ideal for reactor vessels, material stress tests, or temperature simulations. These instruments cover a working temperature of -92 to +250 °C with high cooling and heating capacity.
• USB connection
• For highly precise, external temperature applications
• Rapid heating and cooling
• Wide working temperature ranges without changing fluids
• Highest performance with small footprint
• Space-saving design optimizes space utilization in your lab
• Ethernet interface
• SD-Card slot
• RS232 / RS485 (optional) / Profibus DP (optional)
• Connections for alarm-output, Pt100 external sensor and standby-input
• Removable ventilation grid
• Highly precise ICC cascade temperature control
• Electronic level indication
• Integrated programmer
• Unsurpassed power and efficiency
• Space optimized design creates more room directly next to the units
• External Pt100 sensor connection
Compare
%
Miele A 605 module
Module for optimum reprocessing of vials and test tubes, etc.
• Equipped with 98 injector nozzles
• Max. H 160 mm, max. Ø 20 mm
• For use in A 503 mobile unit
Machine affiliation:
PLW 8615
PLW 8616
PLW 8617
Compare
%
Julabo DYNEO DD-BC6 Heating circulator
DYNEO DD heating circulators for internal and external applications are equipped with closed bath tanks. The tanks are well insulated and include a coil for counter-cooling. An integrated drain tap makes emptying the tank safe and clean. The multilingual 3.5-inch color display and unique rotary knob provide for straightforward and intuitive operation.
Optional analog and digital interface
DYNEO thermostats can optionally be equipped with analogue and digital interfaces. To request the options, order number must be extended with .d for the digital and .a for the analog interface (9XXX XXXX.A / 9XXX XXX.D)
Your advantages
• For internal and external applications
• USB connection
• Powerful and infinitely adjustable pressure pump
• Flow rate 27 l/min, pressure 0.7 bar
• Easy switching between internal and external circulation
• Large color TFT display, multilingual interface
• Central rotary knob (controller) simplifies operation
• Integrated programmer for 8 x 60 program steps
• Integrated external Pt100 connection
• RS232 interface or analog interfaces (optional)
• Bath cover included with delivery
• For internal and external applications
• High-quality thermal insulation of the bath tank
• Integrated programmer
• Integrated drain makes emptying liquid easy and safe.
Compare
%
Miele A 606 module
Module for the use of e.g. lab glassware inserts on the top level of A 503 mobile units.
• Area of application: reprocessing laboratory glassware
• With spray arm
Machine affiliation:
PLW 8615
PLW 8616
PLW 8617
Compare
%
Miele A 612 module
Module for the optimum reprocessing of large-volume laboratory glassware.
• Can be equipped with injector nozzles based on individual needs
The maximum diameter of the load items depends on the number of nozzles used. Nozzles required depending on items: A 846, A 847 and/or A 848.
• Suitable for 2–10 l laboratory flasks, 2–6 l round flasks
The maximum diameter of the wash items depends on the number of nozzles used. Nozzles required depending on items: A 846, A 847, and/or A 848.
• Suitable for 2–5 l Erlenmeyer flasks, 2–5 l measuring flasks
The maximum diameter of the wash items depends on the number of nozzles used. Nozzles required depending on items: A 846, A 847, and/or A 848.
• For use in A 503 mobile unit
Machine affiliation:
PLW 8615
PLW 8616
PLW 8617
Compare
%
Miele A 613 module
Module for the optimum reprocessing of volumetric and measuring pipettes.
• Equipped with 98 injector nozzles
• Suitable for measuring pipettes *with a volume of 1–50 ml.
• Suitable for volumetric pipettes *with a volume of 1–100 ml.
• For use in A 503 mobile unit
*(Capacity depends on the maximum diameter of the pipettes.)
Machine affiliation:
PLW 8615
PLW 8616
PLW 8617
Compare