English
English
Magyar
Home
About us
Shop By Products
Shop By Brand
Contact us
blog
My Cart
Sign in
Public pricelist HUF
Prev
2
3
4
5
6
7
8
Next
Sort by
Relevance
Catalog price: High to Low
Catalog price: Low to High
Name - A to Z
Name - Z to A
Product Sequence Low to High
Product Sequence High to Low
All products
%
Miele PLW 8636 [LAB] SST laboratory washer
Laboratory washer w. liquid dispensing, DryPlus and oil-resistant door seals
• Construction type: Freestanding, wide
• Casing: Stainless Steel
• Number of wash levels: 2
• Salt container in the wash cabinet ceiling
• Electric door lock
Control system
• Control type: SPS
• Programmable
• Selectable display languages
Standard electrical connection
• Electrical connection: 3N AC 400V 50HZ
• Total rated load in kW: 9,2
Water connection/drainage
• Cold water [number]: 1
• Cold water for steam condenser: 2
• Hot water [number]: 1
• DI water [number]: 1
• Required flow pressure in kPa: 200-1000
Drying unit
• Air throughput in m³/h: 66
• HEPA filter class H14, HEPA filter filtration efficiency (in accordance with DIN EN1822) in %: 99,99,
• Heat dissipation into the room in MJ/h: 4,32
Features
• 2 integrated dispenser pumps and containers for liquid media
• Additional integrated dispensing pump 5–10 l (optional)
• Suction lance for media canisters 10–20 l (optional)
• Automatic empty level detection
• Additional integrated dispenser pumps (optional)
• Dispensing monitoring with oval-wheel counter (optional)
• Connection for external recycling tank (option)
• Spray pressure monitoring, redundant temperature monitoring
• Triple water filter system
• Interface for process documentation
• Pump with high circulation rate
• Load carrier – direct coupling
• USB Customer Service interface
• Setting options for process chemicals (3 x 5 l / 2 x 10 l)
• Wash cabinet seamlessly welded using laser technology
• Heater elements outside wash cabinet
• Wash cabinet made from high-quality stainless steel (1.4301/304)
Connection options
• Ethernet interface
Compare
%
Miele PLW 8636 [LAB MON] SST laboratory washer
Laboratory washer w. liquid dispensing, DryPlus, process monitoring and oil-resistant door seals
• Construction type: Freestanding, wide
• Casing: Stainless Steel
• Number of wash levels: 2
• Salt container in the wash cabinet ceiling
• Electric door lock
Control system
• Control type: SPS
• Programmable
• Selectable display languages
Standard electrical connection
• Electrical connection: 3N AC 400V 50HZ
• Total rated load in kW: 9,2
Water connection/drainage
• Cold water [number]: 1
• Cold water for steam condenser: 2
• Hot water [number]: 1
• DI water [number]: 1
• Required flow pressure in kPa: 200-1000
Drying unit
• Air throughput in m³/h: 66
• HEPA filter class H14, HEPA filter filtration efficiency (in accordance with DIN EN1822) in %: 99,99,
• Heat dissipation into the room in MJ/h: 4,32
Features
• 2 integrated dispenser pumps and containers for liquid media
• Additional integrated dispensing pump 5–10 l (optional)
• Suction lance for media canisters 10–20 l (optional)
• DOS monitoring (optional)
• Automatic empty level detection
• Additional integrated dispenser pumps (optional)
• Dispensing monitoring with oval-wheel counter
• Connection for external recycling tank (option)
• Spray and arm pressure monitoring, redundant temperature monitoring
• Triple water filter system
• Interface for process documentation
• Pump with high circulation rate
• Load carrier – direct coupling
• USB Customer Service interface
• Setting options for process chemicals (3 x 5 l / 2 x 10 l)
• Wash cabinet seamlessly welded using laser technology
• Heater elements outside wash cabinet
• Wash cabinet made from high-quality stainless steel (1.4301/304)
Connection options
• Ethernet interface
Compare
%
Vestfrost VT146 Laboratory Chest Freezer
The Vestfrost VT146 is a reliable, low-temperature laboratory chest freezer capable of maintaining temperatures as low as −45 °C. It is an excellent choice for hospitals, laboratories, and research institutions where stable, safe, and energy-efficient storage is essential.
Product Features
• Temperature range: −10 °C to −45 °C
• Outstanding temperature stability: ±5.5 °C uniformity relative to the setpoint
• Easy-to-clean interior: smooth, painted steel surface
• Static cooling system with single compressor
• Energy consumption: approx. 1.865 kWh / 24 hours (≈ 681 kWh/year)
• Insulation: 80 mm thick polyurethane foam with cyclopentane
• Alarms: high/low temperature, probe failure
• XR30CX digital controller with 3-digit display
• Lockable lid, 1 steel basket with plastic coating
• Porthole (Ø12 mm) for external probe or monitoring system
• Mobile design: equipped with castors
Compare
%
Vestfrost VT147 Laboratory Chest Freezer
The Vestfrost VT147 is a reliable low-temperature laboratory chest freezer capable of maintaining temperatures down to −60 °C. Despite its compact size, it delivers strong performance and temperature stability, making it ideal for laboratories, hospital departments, and research facilities where space-saving cold storage is essential.
Product Features
• Temperature range: −40 °C to −60 °C
• Temperature uniformity: ±6.2 °C from the setpoint
• Static cooling with single-compressor system
• Environmentally friendly Nature R (R290) refrigerant
• 80 mm thick polyurethane insulation with cyclopentane
• Energy consumption: 3.707 kWh / 24 hours
• XR30CX digital controller with temperature and probe failure alarms
• Easy-to-clean painted steel interior
• 1 steel basket with plastic coating
• Lockable lid, mounted on castors for mobility
• Ø12 mm porthole for external probe or monitoring connection
• Ideal for the safe and stable low-temperature storage of laboratory samples, reagents, and pharmaceuticals
Compare
%
Heidolph Hei-Shake Basis Salto Core 4 overhead shaker
Shaker for up to 4 bottles
• The Hei-SHAKE Salto Core has all core functions required for optimum processing of samples that tend to sedimentation
• Wide speed range
• Timer (from 1 minute to 999 hours 59 minutes)
• Integrated RS 232 interface
• The maximum permissible weight is 30 kg, so that samples with a high solid content can be properly mixed (DIN 19529)
• Equipped with an emergency stop switch for safety
• Also suitable for mixing cylinders or wide-neck bottles. Diverse adapters can be used to clamp a large number of different bottle sizes. The recommended maximum height of the vessels is 290 mm, with a maximum diameter of 136 mm.
Compare
%
Fedegari FVG1 vertical lab sterilizer
FVG – VERTICAL LAB STERILIZER
A COMPACT AND ERGONOMIC CHOICE.
• Applications: Bio-Pharmaceutical, Microbiology
• Loads: Sealed & unseald containers, Machine parts, Tools, Culture Media, Glassware
• Processes: Sterilization
• Useful chamber capacity: 50, 75,140 liters
FVG Vertical Lab Sterilizer combines excellent performances with overall high quality materials, simplicity of use and optimal consumption.
All FVG series autoclaves are equipped with a built-in steam generator with automatic water feed pump. These autoclaves can treat a wide range of laboratory goods with reliable sterilization technology, such as: glassware and plastic articles, unwrapped instruments, machine parts and components, porous goods, culture media and liquids in open small size containers, laboratory regular waste in open bags.
The FVG series sterilizers are suitable for the sterilization and decontamination in many different laboratory sectors as:
Private and public microbiology labs.
High schools and universities.
Research institutes.
Life science and biotech labs.
Please, click on the image “recommended kit” to check out all possible configurations referred to FVG series.
DESIGN AND TECHNICAL FEATURES
FVG series can be provided in three different chamber useful volumes: 50 liters (FVG1) – 75 liters (FVG2) – 140 liters (FVG3).
Sterilization chamber and lid are made of 316L stainless steel, with mirror polished sanitary finishing. FVG operates at high-pressure (3,5 bar g) and temperature (140°C).
Exclusive horizontal swiveling lid with pneumatic gasket “rotate-and-seal”, for improved user safety. FVG is equipped with a heat recovering system for water preheating to steam generator, assuring utilities cost saving.
FVG has TSC 09 microprocessor control system with graphic color LCD display and an exclusive dual sensor system, by pressure and temperature, for double regulation and control of the sterilization process.
KEY BENEFITS
• Ergonomically designed chamber for maximizing loadable capacity.
• Quick connections to all utilities for easy handling and installation.
• Timed free steaming with pulses for effective air removal.
• 14 free configurable automatic programs.
• Multilevel passwords protected key-users access to ensure process safety.
• Set of four castors for easy moving and installation in lab room.
• GLP compliance
COMPLIANT TO
• PED Directive 2014/68/UE – Pressure equipment
• Machine Directive Macchine 2006/42/EC
• EMC Directive 2014/35/UE
• LVD Directive 2006/95/UE
Compare
%
Vestfrost VT206 Laboratory Chest Freeser
The Vestfrost VT206 is a reliable, low-temperature laboratory chest freezer capable of maintaining temperatures as low as −45 °C. It is an excellent choice for hospitals, laboratories, and research institutions where stable, safe, and energy-efficient storage is essential.
Product Features
• Temperature range: −10 °C to −45 °C
• Outstanding temperature stability: ±5.5 °C uniformity relative to the setpoint
• Easy-to-clean interior: smooth, painted steel surface
• Static cooling system with single compressor
• Energy consumption: approx. 2.274 kWh / 24 hours
• Insulation: 80 mm thick polyurethane foam with cyclopentane
• Alarms: high/low temperature, probe failure
• XR30CX digital controller with 3-digit display
• Lockable lid, 1 steel basket with plastic coating
• Porthole (Ø12 mm) for external probe or monitoring system
• Mobile design: equipped with castors
Compare
%
Vestfrost ULTF-C74i ultra-low temperature chest freezer
The Vestfrost ULTF‑C198i is a high-capacity, professional ultra-low temperature chest freezer designed specifically for the secure, long-term storage of sensitive samples — with no compromises and reliable temperature stability.
Key advantages:
• Temperature range: -20 °C to -86 °C (ETR‑System™)
• Net volume: 189 liters (gross 198 l) – ideal for medium sample quantities
• Chest design: economical solution; horizontal lid ensures excellent cold retention
• i-Care controller: 5″ multilingual touchscreen (EN, DE, FR), USB data logging, live temperature graph and event log
• Static cooling: uniform and stable temperature distribution
• Alarms: temperature fluctuations, probe failure, power outage
• Energy consumption: approx. 5.9 kWh / 24 h (set at -82 °C)
• Storage capacity: up to 11,700 pcs of 2 ml vials or 117 pcs of 2″ cryoboxes
• Mobility: 4 lockable castors for easy movement
Recommended applications:
Long-term freezing of biological samples, cell lines, DNA/RNA, vaccines, and pharmaceuticals in research laboratories, biobanks, and healthcare facilities where reliable ULT performance and medium footprint are required.
Compare
%
Esco AC2-3E8-NS G4 8” Airstream® Class II Type A2 biological safety cabinet
The new BSC with Centurion Touchscreen controller is NSF-certified with standby height that easily activates standby mode, an ergonomic work zone that is comprised of bright illumination using industry-leading dimmable LED combined with raised, durable, stainless-steel armrest.
The Airstream® NS (E-series) G4 incorporates greener features, ensuring a more sustainable and environmentally friendly operation. With its compact size and advanced features, this biosafety cabinet offers an unparalleled level of convenience and safety, making it the ideal choice for laboratories and research facilities.
Features
• Centurion Touchscreen Controller
Intuitive, comprehensive, and easy-to-understand
Virtually comprehensible safety information and cabinet alarms via 3D BSC diagram
Defined details of alarm types with clear instructions for proper intervention
Centered and angled down for easy reach & viewing
Selectable Quickstart mode for fast operation
• Dimmable LED
Adjustable work zone brightness
Ideal light intensity of 1200 lux
Saves energy and optimizes work comfort
• Ergonomic Features
8” (203 mm) sash opening
Frameless, shatterproof, and UV-absorbing tempered glass
• USB Port and Remote Modbus
USB port to access cabinet data log and BMS connectivity
Newly integrated Remote Modbus feature for users to securely access the cabinet remotely from external devices.
• Cabinet Construction
E-Series:
Tempered Glass Side walls - increases visibility and prevents the operator from experiencing a "boxed-in" feeling
Multi-piece work tray, autoclavable
• Green Product
Equipped with energy-efficient DC ECM that allows up to 70% energy savings vs AC motor
Extremely low energy consumption with 184 watts (4 ft unit)
Standby mode allows reduced power consumption
• ULPA Filter
10x filtration efficiency compared to the HEPA filter
Creates ISO Class 3 work zone instead of industry-standard, ISO Class 5
Same 10 years filter life and replacement cost as HEPA filters
*99.999% at 0.1 to 0.3 micron, ULPA as per IEST-RP-CC001.3 USA
*99.999% at MPPS, H14 as per EN 1822 EU
• Isocide™ Antimicrobial Powder Coating
Eliminates 99.9% of surface bacteria within 24 hours of exposure
Compare
%
Esco AC2-3S8-NS G4 8” Airstream® Class II Type A2 biological safety cabinet
The new BSC with Centurion Touchscreen controller is NSF-certified with standby height that easily activates standby mode, an ergonomic work zone that is comprised of bright illumination using industry-leading dimmable LED combined with raised, durable, stainless-steel armrest. It also comes with wider model options offering stainless steel (S-series) and glass (E-series) side wall variants.
The Airstream® NS (S-series) G4 incorporates greener features, ensuring a more sustainable and environmentally friendly operation. With its compact size and advanced features, this biosafety cabinet offers an unparalleled level of convenience and safety, making it the ideal choice for laboratories and research facilities.
Features
• Centurion Touchscreen Controller
Intuitive, comprehensive, and easy-to-understand
Virtually comprehensible safety information and cabinet alarms via 3D BSC diagram
Defined details of alarm types with clear instructions for proper intervention
Centered and angled down for easy reach & viewing
Selectable Quickstart mode for fast operation
• Dimmable LED
Adjustable work zone brightness
Ideal light intensity of 1200 lux
Saves energy and optimizes work comfort
• Ergonomic Features
8” (203 mm) sash opening
Frameless, shatterproof, and UV-absorbing tempered glass
• Tray support beams and holder
Support beams for less vibration and holder for easy drain pan cleaning
• USB Port and Remote Modbus
USB port to access cabinet data log and BMS connectivity
Newly integrated Remote Modbus feature for users to securely access the cabinet remotely from external devices.
• Cabinet Construction
S-Series:
Stainless steel side walls with side capture zones and negative pressure to optimize containment
Single-piece work tray, spill retaining and easy to clean
• Green Product
Equipped with energy-efficient DC ECM that allows up to 70% energy savings vs AC motor
Extremely low energy consumption with 184 watts (4 ft unit)
Standby mode allows reduced power consumption
• ULPA Filter
10x filtration efficiency compared to the HEPA filter
Creates ISO Class 3 work zone instead of industry-standard, ISO Class 5
Same 10 years filter life and replacement cost as HEPA filters
*99.999% at 0.1 to 0.3 micron, ULPA as per IEST-RP-CC001.3 USA
*99.999% at MPPS, H14 as per EN 1822 EU
• Isocide™ Antimicrobial Powder Coating
Eliminates 99.9% of surface bacteria within 24 hours of exposure
Compare
%
Nabertherm LT 5/13/B510 muffle furnace with brick insulation
Heating elements on support tubes radiating freely into the furnace chamber provide for particularly short heating times for these muffle furnaces. Thanks to their robust lightweight refractory brick insulation, they can reach a maximum working temperature of 1300 °C. These muffle furnaces thus represent an interesting alternative to the familiar L(T) ../12 models, when you need a higher application temperature.
Standard Equipment
• Heating from two sides
• Heating elements on support tubes ensure free heat radiation and a long service life
• Multi-layer insulation with robust lightweight refractory bricks in the furnace chamber
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• With lift door (LT)
• Adjustable air inlet in the furnace door
• Exhaust air outlet in rear wall of furnace
• Solid state relays provide for lownoise operation
• Controller with touch operation B510 (5 programs with each 4 segments)
Option
• Chimney, chimney with fan or catalytic converter
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door
Compare
%
Nabertherm L 1/12/R7 muffle furnace
The muffle furnaces L have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.
Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type S (1200 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With flap door (L)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Solid state relays provide for lownoise operation
• R7 (1 program with 1 segment)
Option
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door
Compare
%
Julabo IC40 Immersion cooler
Modern immersion coolers with natural refrigerant for rapid cool-down of fluids
JULABO immersion coolers are mainly used for counter-cooling in conjunction with heating circulators or for rapid cooling of fluids to low temperatures. The modern IC Series works with natural, climate-friendly refrigerants.
The IC40 immersion cooler was developed with a focus on high user-friendliness. The removable venting grid, which can be removed without tools, facilitates regular cleaning for maximum performance over the unit's entire life-time. The magnetic probe holder enables flexible and stable attachment of the probe to magnetic surfaces, ensuring hassle-free positioning for various applications.
Product Features
• Rapid cooling of liquids down to low temperatures
• Counter-cooling of liquids in combination with heating circulators
• Preventing the use of precious tap water for cooling
• Ease of operation
• Dry ice substitution
• Dimensions immersion probe cylindrical Length cm(L x Ø): 10x5
Compare
%
Binder KBF 470 Photostability Climat Chamber with ICH light modul with light-dose control (LQC)
The Binder KBF 470 standard climate chamber offers a reliable solution for photostability testing in accordance with the ICH Q1B guideline. The unit can be easily equipped with the ICH LQC light module, which provides UV and visible (VIS) light to create a standardized test environment. The ICH LQC module also includes a VIS and a UVA sensor for precise light dose control. The lighting switches off automatically once the programmed light dose reaches the desired value, ensuring that the test is carried out under fully controlled conditions. The system is designed so that the photostability test can be completed within three days while minimizing thermal impact on the test material.
KBF models provide a stable and controlled environment, making them ideal for industrial and research-based photostability applications where the reproducibility of test results is a key requirement.
Scope of delivery
Binder KBF 470 Constant climate chambers with a large temperature / humidity range
• Climate range: +20 °C to +50 °C and 20% to 50% RH
• Proven APT.line ™ preheating chamber technology
• Energy-efficient cooling with modern inverter cooling unit
• Cooling with climate-neutral R-600a refrigerant
• Door heating to prevent condensation
• Adjustable fan speed
• Humidity regulation with capacitive humidity sensor and responsive steam humidification
• Robust housing design with HIT sandwich technology
• Stainless steel inner chamber
• Inner doors made of metal oxide-coated safety glass
• Two racks made of stainless steel
• Large access ports with silicone plug
• Robust twin casters, with brakes at the front
• Intuitive touchscreen controller with time-segment and real-time programming
• Ergonomically adjustable control terminal
• Signal triangle with light-up status display
• Internal data logger, measured values can be read out in open format via USB
• Class 3.3 independent temperature safety device (DIN 12880) with visual and acoustic alarms
• Unit self-test for comprehensive status analysis
• Data interfaces: Ethernet, USB
• BINDER Multi Management Software APT-COM™ basic edition
BINDER ICH-LQC light module
The ICH-LQC light module contains two spherical light sensors in addition. The VIS sensor measures the illuminance of visible light and the UVA sensor measures the irradiance of UVA light. Both sensors evaluate the light with a spherical characteristic, which is useful for three-dimensional test objects. The light dose must be increased by a factor of 1.5 for photostability tests on flat test objects, such as printed products.
The ICH light module is also connected to the climate chamber via a data cable and the light control runs via the program controller. The light dose to be achieved for the two types of light is entered in the controller (typically 1.2 Mlx h visible light and 200 Wh/m² UVA) and the light cassettes are automatically switched off individually once the dose has been reached.
Scope of delivery of the BINDER ICH-LQC light module
• VIS light cassette with connection cable
• UVA light cassette with connection cable
• Spherical VIS light sensor for light dose control
• Spherical UVA light sensor for light dose control
• U-rails for mounting the light cassettes in the climate control cabinet
• Supply box with ballasts/power supply units
• Profile rails and bolts for attaching the supply box to the climate chamber
• Data cable
• Mains cable
• Operating instructions
Compare
%
Binder KBF PRO 470 Photostability Climat Chamber with ICH light modul with light-dose control (LQC)
The Binder KBF PRO 470 standard climate chamber with extended temperature and humidity range is an ideal choice for photostability testing in accordance with the ICH Q1B guideline. The unit can be easily equipped with the ICH LQC light module, which provides UV and visible (VIS) light to create a standardized test environment. The ICH LQC module also includes a VIS and a UVA sensor for precise light dose control. The lighting switches off automatically once the programmed light dose reaches the desired value, ensuring that the test is carried out under fully controlled conditions. The system is designed so that the photostability test can be completed within three days while minimizing thermal impact on the test material.
Package contents
Binder KBF PRO 470 Constant climate chamber with expanded temperature / humidity range
• Climate range: +10 °C to +50 °C and 10% to 80% RH
• Proven APT.line ™ preheating chamber technology
• Energy-efficient cooling with modern inverter cooling unit
• Cooling with climate-neutral R-290 refrigerant
• Door heating to prevent condensation
• Adjustable fan speed
• Humidity regulation with capacitive humidity sensor and responsive steam humidification
• Robust housing design with HIT sandwich technology
• Stainless-steel inner chamber
• Inner doors made of metal oxide-coated safety glass
• Two racks made of stainless steel with telescopic rails
• Large access port with silicone plug
• Robust twin casters, with brakes at the front
• Intuitive touchscreen controller with time-segment and real-time programming
• Ergonomically adjustable control terminal
• Signal triangle with light-up status display
• Internal data logger, measured values can be read out in open format via USB
• Class 3.3 independent temperature safety device (DIN 12880) with visual and acoustic alarms
• Unit self-test for comprehensive status analysis
• Data interfaces: Ethernet, USB
• BINDER Multi Management Software APT-COM™ basic edition
BINDER ICH-LQC light module
The ICH-LQC light module contains two spherical light sensors in addition. The VIS sensor measures the illuminance of visible light and the UVA sensor measures the irradiance of UVA light. Both sensors evaluate the light with a spherical characteristic, which is useful for three-dimensional test objects. The light dose must be increased by a factor of 1.5 for photostability tests on flat test objects, such as printed products.
The ICH light module is also connected to the climate chamber via a data cable and the light control runs via the program controller. The light dose to be achieved for the two types of light is entered in the controller (typically 1.2 Mlx h visible light and 200 Wh/m² UVA) and the light cassettes are automatically switched off individually once the dose has been reached.
Scope of delivery of the BINDER ICH-LQC light module
• VIS light cassette with connection cable
• UVA light cassette with connection cable
• Spherical VIS light sensor for light dose control
• Spherical UVA light sensor for light dose control
• U-rails for mounting the light cassettes in the climate control cabinet
• Supply box with ballasts/power supply units
• Profile rails and bolts for attaching the supply box to the climate chamber
• Data cable
• Mains cable
• Operating instructions
Compare
%
Binder KB PRO 470 Photostability Test Chamber with ICH light modul with light-dose control (LQC)
The Binder KB PRO 470 incubator is an ideal choice for photostability testing in accordance with ICH guideline Q1B. The unit can be easily equipped with the ICH LQC light module, which provides UV and visible (VIS) light to create a standardized test environment. The ICH LQC module also includes a VIS and a UVA sensor for precise light dose control. The lighting switches off automatically once the programmed light dose reaches the desired value, ensuring that the test is carried out under fully controlled conditions. The system is designed so that the photostability test can be completed within three days while minimizing thermal impact on the test material.
Scope of delivery
Binder KB PRO 470 Cooling incubator
• Temperature range: +5 °C bis +60 °C
• Proven APT.line ™ preheating chamber technology
• Energy-efficient cooling with modern inverter cooling unit
• Cooling with climate-neutral R-290 refrigerant
• Door heating to prevent condensation
• Adjustable fan speed
• Robust housing design with HIT sandwich technology
• Stainless-steel inner chamber
• Inner doors made of metal oxide-coated safety glass
• Two racks made of stainless steel
• Large access port with silicone plug
• Robust twin casters, with brakes at the front
• Intuitive touchscreen controller with time-segment and real-time programming
• Ergonomically adjustable control terminal
• Internal data logger, measured values can be read out in open format via USB
• Class 3.3 independent temperature safety device (DIN 12880) with visual and acoustic alarms
• Unit self-test for comprehensive status analysis
• Data interfaces: Ethernet, USB
• BINDER Multi Management Software APT-COM™ basic edition
BINDER ICH-LQC light module
The ICH-LQC light module contains two spherical light sensors in addition. The VIS sensor measures the illuminance of visible light and the UVA sensor measures the irradiance of UVA light. Both sensors evaluate the light with a spherical characteristic, which is useful for three-dimensional test objects. The light dose must be increased by a factor of 1.5 for photostability tests on flat test objects, such as printed products.
The ICH light module is also connected to the climate chamber via a data cable and the light control runs via the program controller. The light dose to be achieved for the two types of light is entered in the controller (typically 1.2 Mlx h visible light and 200 Wh/m² UVA) and the light cassettes are automatically switched off individually once the dose has been reached.
Scope of delivery of the BINDER ICH-LQC light module
• VIS light cassette with connection cable
• UVA light cassette with connection cable
• Spherical VIS light sensor for light dose control
• Spherical UVA light sensor for light dose control
• U-rails for mounting the light cassettes in the climate control cabinet
• Supply box with ballasts/power supply units
• Profile rails and bolts for attaching the supply box to the climate chamber
• Data cable
• Mains cable
• Operating instructions
Compare
%
Binder KBF 470 Photostability Climat Chamber with ICH light modul
The Binder KBF 470 standard climate chamber offers a reliable solution for photostability testing in accordance with the ICH Q1B guideline. The chamber can optionally be equipped with an ICH-compatible light module that provides standardized UV and visible light (VIS) exposure for the samples. The unit is designed to enable accurate and efficient execution of the three-day photostability test with minimal thermal impact. KBF models provide a stable and controlled environment, making them ideal for industrial and research-based photostability applications where the reproducibility of test results is a key requirement.
Scope of delivery
Binder KBF 470 Constant climate chambers with a large temperature / humidity range
• Climate range: +20 °C to +50 °C and 20% to 50% RH
• Proven APT.line ™ preheating chamber technology
• Energy-efficient cooling with modern inverter cooling unit
• Cooling with climate-neutral R-600a refrigerant
• Door heating to prevent condensation
• Adjustable fan speed
• Humidity regulation with capacitive humidity sensor and responsive steam humidification
• Robust housing design with HIT sandwich technology
• Stainless steel inner chamber
• Inner doors made of metal oxide-coated safety glass
• Two racks made of stainless steel
• Large access ports with silicone plug
• Robust twin casters, with brakes at the front
• Intuitive touchscreen controller with time-segment and real-time programming
• Ergonomically adjustable control terminal
• Signal triangle with light-up status display
• Internal data logger, measured values can be read out in open format via USB
• Class 3.3 independent temperature safety device (DIN 12880) with visual and acoustic alarms
• Unit self-test for comprehensive status analysis
• Data interfaces: Ethernet, USB
• BINDER Multi Management Software APT-COM™ basic edition
ICH light module without light dose control
The ICH light module is connected to the climate chamber via a data cable. This makes it possible to control the irradiation duration of the light cassettes individually with a time segment program via the program controller of the climate chamber.
Scope of delivery of the BINDER ICH light modules
• VIS light cassette with connection cable
• UVA light cassette with connection cable
• U-rails for mounting the light cassettes in the climate control cabinet
• Supply box with ballasts/power supply units
• Profile rails and bolts for attaching the supply box to the climate chamber
• Data cable
• Mains cable
• Operating instructions
Compare
%
Binder KBF PRO 470 Photostability Climat Chamber with ICH light modul
The Binder KBF PRO 470 standard climate chamber with extended temperature and humidity range is an ideal choice for photostability testing in accordance with the ICH Q1B guideline. The chamber can be equipped with a special ICH light module that provides standardized UV and visible light (VIS) exposure. The system is designed to enable fast and reliable completion of the three-day photostability test with minimal thermal impact. The KBF PRO 470 ensures a precise and stable environment, guaranteeing the reproducibility of test results in various industrial and research applications.
Package contents
Binder KBF PRO 470 Constant climate chamber with expanded temperature / humidity range
• Climate range: +10 °C to +50 °C and 10% to 80% RH
• Proven APT.line ™ preheating chamber technology
• Energy-efficient cooling with modern inverter cooling unit
• Cooling with climate-neutral R-290 refrigerant
• Door heating to prevent condensation
• Adjustable fan speed
• Humidity regulation with capacitive humidity sensor and responsive steam humidification
• Robust housing design with HIT sandwich technology
• Stainless-steel inner chamber
• Inner doors made of metal oxide-coated safety glass
• Two racks made of stainless steel with telescopic rails
• Large access port with silicone plug
• Robust twin casters, with brakes at the front
• Intuitive touchscreen controller with time-segment and real-time programming
• Ergonomically adjustable control terminal
• Signal triangle with light-up status display
• Internal data logger, measured values can be read out in open format via USB
• Class 3.3 independent temperature safety device (DIN 12880) with visual and acoustic alarms
• Unit self-test for comprehensive status analysis
• Data interfaces: Ethernet, USB
• BINDER Multi Management Software APT-COM™ basic edition
ICH light module without light dose control
The ICH light module is connected to the climate chamber via a data cable. This makes it possible to control the irradiation duration of the light cassettes individually with a time segment program via the program controller of the climate chamber.
Scope of delivery of the BINDER ICH light modules
• VIS light cassette with connection cable
• UVA light cassette with connection cable
• U-rails for mounting the light cassettes in the climate control cabinet
• Supply box with ballasts/power supply units
• Profile rails and bolts for attaching the supply box to the climate chamber
• Data cable
• Mains cable
• Operating instructions
Compare
%
Binder KB PRO 470 Photostability Test Chamber with ICH light modul
The Binder KB PRO 470 incubator is an ideal choice for photostability testing in accordance with ICH guideline Q1B. The unit can be easily equipped with an ICH light module, which provides UV and visible (VIS) light to create a standardized test environment. The system is designed to complete the photostability test within three days while minimizing thermal impact on the test material.
Scope of delivery
Binder KB PRO 470 Cooling incubator
• Temperature range: +5 °C bis +60 °C
• Proven APT.line ™ preheating chamber technology
• Energy-efficient cooling with modern inverter cooling unit
• Cooling with climate-neutral R-290 refrigerant
• Door heating to prevent condensation
• Adjustable fan speed
• Robust housing design with HIT sandwich technology
• Stainless-steel inner chamber
• Inner doors made of metal oxide-coated safety glass
• Two racks made of stainless steel
• Large access port with silicone plug
• Robust twin casters, with brakes at the front
• Intuitive touchscreen controller with time-segment and real-time programming
• Ergonomically adjustable control terminal
• Internal data logger, measured values can be read out in open format via USB
• Class 3.3 independent temperature safety device (DIN 12880) with visual and acoustic alarms
• Unit self-test for comprehensive status analysis
• Data interfaces: Ethernet, USB
• BINDER Multi Management Software APT-COM™ basic edition
ICH light module without light dose control
The ICH light module is connected to the climate chamber via a data cable. This makes it possible to control the irradiation duration of the light cassettes individually with a time segment program via the program controller of the climate chamber.
Scope of delivery of the BINDER ICH light modules
• VIS light cassette with connection cable
• UVA light cassette with connection cable
• U-rails for mounting the light cassettes in the climate control cabinet
• Supply box with ballasts/power supply units
• Profile rails and bolts for attaching the supply box to the climate chamber
• Data cable
• Mains cable
• Operating instructions
Compare
%
Liebherr SFTsg 1501 laboratory freezer, with drawers
Sensitive substances are optimally stored and protected in this undercounter freezer for laboratories. The high-performance freezer impresses with reliable temperature stability and assorted safety functions, as well as SmartFrost, which significantly reduces frost buildup in the interior.
Product features
• ±5 °C temperature stability
Sensitive substances cannot be subjected to large deviations from the set storage temperature. Liebherr freezers guarantee a minimal temperature fluctuation of no more than ±5 °C. This means that your valuable contents are optimally protected against impairment and their quality is preserved.
• SmartFrost
SmartFrost reduces frost build-up in the interior and on stored products. Defrosting is required less often – and when it is necessary, it is made much easier by the smooth, easy-to-clean interior walls. The evaporator in the foam insulation ensures high levels of energy efficiency as well as even cooling.
• Retrofittable WiFi/LAN interface
This is how easy it is to network a Liebherr: With the retrofittable WiFi and LAN interface, appliances can be effortlessly connected to external systems, such as SmartMonitoring from Liebherr. With the digital monitoring solution, the storage temperature is controlled and documented conveniently and securely via the subsequently set up interface.
• SmartMonitoring (optional)
The cloud-based digital solution continuously monitors and documents temperatures and alerts you immediately via email, text message or phone if any deviations occur
• Designed for a service life of 15 years
Sustainable means the appliance is not only economical, but also durable. High-quality materials and solid workmanship, coupled with at least ten years of spare parts availability, make a Liebherr appliance a robust, reliable, and extremely long-lasting top performer in demanding everyday work.
• Easy to clean interior
The plastic inside container is made of polystyrene: a fully recyclable, robust, and odourless plastic. Manufactured seamlessly from one piece, it has no hidden dirt traps and the large corner radii can be cleaned quickly and easily. The perfect combination of sustainability and hygiene.
• Alarm relay
In the event of an alarm, the responsible control centre is informed immediately, usually through connection to the building control system. You can define in advance which alarms are to be forwarded, as well as set how long the forwarding remains active and whether a reminder should be sent after the alarm acknowledgement. This allows you to react immediately in critical situations.
• Replaceable door seal
Save time and money: Liebherr's plug-in door seals can be easily replaced. If a seal is damaged, you can replace it yourself without any tools.
• Mechanical lock
Liebherr professional appliances are equipped with a mechanical lock and two keys. This ensures that unauthorized persons cannot access your valuable and sensitive stored goods.
• Feedthrough for external sensors
To additionally control the storage temperature with the help of a separate sensor, wiring from the outside to the inside is required. The cable feeding offers a clean and professional solution here. The integrated opening allows connection without drilling holes or breaking the door seal.
• Min./max. temperature recording
Always keep an eye on the temperature: Min./max. temperature recording stores the minimum and maximum temperature values of the interior that have occurred from a defined start time and shows them clearly in the display. This way you can be sure that, up until the moment you read off the values, the storage temperatures were always within the tolerated limits.
Compare
Prev
2
3
4
5
6
7
8
Next