Other accessories

%
Miele APH510 PRT110 Protocol printer
Protocol printer for printing process protocols
• Dotmatrix printer with ink ribbon
• Colour: Black
• Compatible with all Miele cleaning/disinfecting devices (Except PG 852x, PG 853x and PG 89xx.brThe XKM RS232 10 Med serial communication module is also required for the Miele PG 858x and PG 859x cleaning and disinfecting devices.)
%
Miele XKM RS 232 10 Med communication module
Communication modulewith serial interface (RS232) for connection to a printer.
• Ring memory for max. 25 process reports
• Difference between short and long report
• Transfer speed: max. 38 kBit/s
• Length of supply lead: 1.5 m; extension up to 15 m possible


Machine affiliation: Can be used for PG 8583, PG 8583 CD, PG 8593 devices.
%
Miele XKM 3000LMed communication module
Communication module with Ethernet interface for connecting to a network.
• Ring memory for up to 30 process and 2 graphic protocols
• No other component is required for direct/network connection
• DHCP support for automatic setting of network parameters
• Transmission speed 10/100 Mbit/s
• Length of the connection cable: 1.5 m; extendable (The connector required for cable extension is included.)

Machine affiliation: Can be used for PG 8583, PG 8583 CD, PG 8593 devices.
%
Miele ID 90 injector nozzle 2,5x90mm
Injector nozzle with plastic supports, Ø 3, length 90 mm.
• Area of application: reprocessing laboratory glassware
• Suitable for measuring flasks and test tubes, for example
• Suitable for standard mobile injector units and injector baskets

Machine affiliation: Can be used for PG 8583, PG 8583 CD, PG 8593 devices.
%
Miele ID 240 injector nozzle 6,0x240mm
Injector nozzle with plastic supports, Ø 6, length 240 mm.
• Area of application: reprocessing laboratory glassware
• Suitable for measuring flasks and test tubes, for example
• Suitable for standard mobile injector units and injector baskets

Machine affiliation: Can be used for PG 8583, PG 8583 CD, PG 8593 devices.
%
Miele ID 220 injector nozzle 6,0x220mm
Injector nozzle with plastic supports, Ø 6, length 220 mm.
• Area of application: reprocessing laboratory glassware
• Suitable for measuring flasks and test tubes, for example
• Suitable for standard mobile injector units and injector baskets

Machine affiliation: Can be used for PG 8583, PG 8583 CD, PG 8593 devices.
%
Miele ID 200 injector nozzle 6,0x200mm
Injector nozzle with plastic supports, Ø 6, length 200 mm.
• Area of application: reprocessing laboratory glassware
• Suitable for measuring flasks and test tubes, for example
• Suitable for standard mobile injector units and injector baskets

Machine affiliation: Can be used for PG 8583, PG 8583 CD, PG 8593 devices.
%
Miele ID 180 injector nozzle 4,0x180mm
Injector nozzle with plastic supports, Ø 4, length 180 mm.
• Area of application: reprocessing laboratory glassware
• Suitable for measuring flasks and test tubes, for example
• Suitable for standard mobile injector units and injector baskets

Machine affiliation: Can be used for PG 8583, PG 8583 CD, PG 8593 devices.
%
Miele ID 160 injector nozzle 4,0x160mm
Injector nozzle with plastic supports, Ø 4, length 160 mm.
• Area of application: reprocessing laboratory glassware
• Suitable for measuring flasks and test tubes, for example
• Suitable for standard mobile injector units and injector baskets

Machine affiliation: Can be used for PG 8583, PG 8583 CD, PG 8593 devices.
%
Miele ID 140 injector nozzle 4,0x140mm
Injector nozzle with plastic supports, Ø 4, length 140 mm.
• Area of application: reprocessing laboratory glassware
• Suitable for measuring flasks and test tubes, for example
• Suitable for standard mobile injector units and injector baskets

Machine affiliation: Can be used for PG 8583, PG 8583 CD, PG 8593 devices.
%
Miele ID 110 injector nozzle 2,5x110mm
Injector nozzle with plastic supports, Ø 3, length 110 mm.
• Area of application: reprocessing laboratory glassware
• Suitable for measuring flasks and test tubes, for example
• Suitable for standard mobile injector units and injector baskets

Machine affiliation: Can be used for PG 8583, PG 8583 CD, PG 8593 devices.
%
Miele E 336 irrigation sleeves
For the optimum loading of pipettes/MIS instruments in injector units.
• Pipettes up to max. 445 mm length can be held
• Plastic, screw connection
%
Miele APH 591 paper roll
Paper roll for protocol printer APH 500 PRT100 and APH 510 PRT110
• 5 paper rolls per pack
• Width: 76 mm
%
Miele APH 590 ink cartridge
Ink cartridge for PRT 100 report printer.
%
Miele APH 302 connection cable type 2
For connection of a machine with serial interface to a PC.
• Null modem cable, length 3 m

Machine affiliation: Can be used in PG 8583, PG 8583 CD, PG 8593 devices.
%
Miele APH 301 connection cable type 1
For connection of a machine with serial interface to a PC.
• Compat. w. Miele PWD853x, PLW611x, PG858x/9x w. XKM RS232 10 Med
• Crossover cable, length 3 m

Machine affiliation: Can be used in PG 8583, PG 8583 CD, PG 8593 devices.
%
Miele A 11/1 insert 1/1
For the gentle cleaning of delicate items by interrupting the spray jet.
• Area of application: reprocessing laboratory glassware
• With perforations 7 x 7 mm
• For use in upper and lower basket

Machine affiliation: Can be used in PG 8583, PG 8583 CD, PG 8593 devices.
%
Miele E 470 injector nozzle 2,5x90mm
For the optimum cleaning of the wash items.
• Area of application: reprocessing laboratory glassware
• For use in the mobile injector unit, Ø 2.5 x 90 mm.
• Suitable for mobile injector units, with screw connection
• Suitable for bottles, Erlenmeyer flasks and round bottomed flasks for example

Machine affiliation: Can be used in PG 8504, PG 8583, PG 8583 CD, PG 8593 and PLW 8617 devices.
%
Miele E 362 blind stopper
For the sealing of fittings to load carriers.
• Area of application: reprocessing laboratory glassware
• Thread M8 x 1
%
Miele E 354 clamps for nozzle 6,0x220 mm
Height-adjustable for optimum positioning of laboratory glassware on the nozzle.
• Area of application: reprocessing laboratory glassware
• Height adjustable locking
• Suitable for bottles, Erlenmeyer flasks and round bottomed flasks for example
• Suitable for injector nozzle E 352

Machine affiliation: Can be used in PG 8504, PG 8583, PG 8583 CD, PG 8593 devices, for E 352 injector nozzles.