Nabertherm L & LT professional muffle furnaces

%
Nabertherm LT40/12/B510 Muffle Furnace
The LT40/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.
Standard Equipment:
• Tmax 1200 °C
• Heating from three sides by ceramic heating plates for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With lift door (LT)
• Dual shell housing made of textured stainless steel sheets with additional fan cooling for low surface temperature
• Exclusive use of insulation materials without categorization according to EC Regulation No. 1272/2008 (CLP)
• Adjustable air inlet integrated in door
• Exhaust air outlet in rear wall of furnace
• Solid state relays provide for lownoise operation
• Defined application within the constraints of the operating instructions
• Controller B510 (5 programs with each 4 segments)
• NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive
Options:
• Overtemperature limit controller
• Protective gas connection
• Hole for thermocouple in rear wall
• Hole for thermocouple in furnace door
• Process control and documentation via VCD software package for monitoring, documentation and control
%
Nabertherm LT 9/12/C550 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.

Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type S (1200 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With lift door (LT)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation C550
• Solid state relays provide for lownoise operation

Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door

%
Nabertherm LT 9/12/B510 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.

Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type S (1200 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With lift door (LT)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation B510 (5 programs with each 4 segments)
• Solid state relays provide for lownoise operation

Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door

%
Nabertherm LT 9/11/C550 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.

Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type N (1100 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With lift door (LT)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation C550
• Solid state relays provide for lownoise operation

Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door

%
Nabertherm LT 9/11/B510 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.

Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type N (1100 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With lift door (LT)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation B510 (5 programs with each 4 segments)
• Solid state relays provide for lownoise operation

Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door

%
Nabertherm LT 60/11/C550 Muffle Furnace
The muffle furnace LT 60/11 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.
Standard Equipment:
• Tmax 1100 °C
• Heating from three sides by ceramic heating plates for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type N (1100 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With lift door (LT)
• Dual shell housing made of textured stainless steel sheets with additional fan cooling for low surface temperature
• Exclusive use of insulation materials without categorization according to EC Regulation No. 1272/2008 (CLP)
• Adjustable air inlet integrated in door
• Exhaust air outlet in rear wall of furnace
• Controller C550 (10 programs with each 20 segments)
• NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive
Options:
• Overtemperature limit controller
• Protective gas connection
• Hole for thermocouple in rear wall
• Hole for thermocouple in furnace door
• Process control and documentation via VCD software package for monitoring, documentation and control
%
Nabertherm LT 5/12/C550 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.

Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type S (1200 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With lift door (LT)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation C550
• Solid state relays provide for lownoise operation

Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door

%
Nabertherm LT 5/12/B510 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.

Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type S (1200 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With lift door (LT)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation B510 (5 programs with each 4 segments)
• Solid state relays provide for lownoise operation

Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door

%
Nabertherm LT 5/11/C550 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.

Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type N (1100 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With lift door (LT)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation C550
• Solid state relays provide for lownoise operation

Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door

%
Nabertherm LT 5/11/B510 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.

Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type N (1100 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With lift door (LT)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation B510 (5 programs with each 4 segments)
• Solid state relays provide for lownoise operation

Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door

%
Nabertherm LT 40/12/C550 Muffle Furnace
The LT40/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.
Standard Equipment:
• Tmax 1200 °C
• Heating from three sides by ceramic heating plates for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With lift door (LT)
• Dual shell housing made of textured stainless steel sheets with additional fan cooling for low surface temperature
• Exclusive use of insulation materials without categorization according to EC Regulation No. 1272/2008 (CLP)
• Adjustable air inlet integrated in door
• Exhaust air outlet in rear wall of furnace
• Solid state relays provide for lownoise operation
• Defined application within the constraints of the operating instructions
• Controller C550 (10 programs with each 20 segments)
• NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive
Options:
• Overtemperature limit controller
• Protective gas connection
• Hole for thermocouple in rear wall
• Hole for thermocouple in furnace door
• Process control and documentation via VCD software package for monitoring, documentation and control
%
Nabertherm LT 40/11/C550 Muffle Furnace
The LT40/11 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.
Standard Equipment:
• Tmax 1100 °C
• Heating from three sides by ceramic heating plates for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With lift door (LT)
• Dual shell housing made of textured stainless steel sheets with additional fan cooling for low surface temperature
• Exclusive use of insulation materials without categorization according to EC Regulation No. 1272/2008 (CLP)
• Adjustable air inlet integrated in door
• Exhaust air outlet in rear wall of furnace
• Solid state relays provide for lownoise operation
• Defined application within the constraints of the operating instructions
• Controller C550 (10 programs with each 20 segments)
• NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive
Options:
• Overtemperature limit controller
• Protective gas connection
• Hole for thermocouple in rear wall
• Hole for thermocouple in furnace door
• Process control and documentation via VCD software package for monitoring, documentation and control
%
Nabertherm LT 3/12/C550 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.

Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type S (1200 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With lift door (LT)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation C550
• Solid state relays provide for lownoise operation

Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door

%
Nabertherm LT 3/12/B510 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.

Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type S (1200 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With lift door (LT)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation B510 (5 programs with each 4 segments)
• Solid state relays provide for lownoise operation

Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door

%
Nabertherm LT 3/11/C550 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.

Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type N (1100 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With lift door (LT)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation C550
• Solid state relays provide for lownoise operation

Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door

%
Nabertherm LT 3/11/B510 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.

Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type N (1100 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With lift door (LT)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation B510 (5 programs with each 4 segments)
• Solid state relays provide for lownoise operation

Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door

%
Nabertherm LT 24/12/C550 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.

Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type S (1200 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With lift door (LT)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation C550
• Solid state relays provide for lownoise operation

Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door

%
Nabertherm LT 24/12/B510 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.

Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type S (1200 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With lift door (LT)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation B510 (5 programs with each 4 segments)
• Solid state relays provide for lownoise operation

Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door

%
Nabertherm LT 24/11/C550 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.

Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type N (1100 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With lift door (LT)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation C550
• Solid state relays provide for lownoise operation

Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door

%
Nabertherm LT 24/11/B510 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.

Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type N (1100 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With lift door (LT)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation B510 (5 programs with each 4 segments)
• Solid state relays provide for lownoise operation

Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door