All products

%
Kühner O₂ controller LT-X
A reliable control of O₂ is essential for cultivating cells (proliferation and metabolism of stem cells) and microorganisms with low/no oxygen demand. The O₂ controller reduces the O₂ level from ambient (20.95% at dry air; normoxia) to approximately 0% O₂ (hypoxic). A digital PID controller adjusts the N2 flow rate to maintain the desired O₂ value.
%
Kühner Clamp U-6000
Clamp U-6000 for Erlenmeyer flasks with 6000 ml vol.
%
Kühner Tray with fixed clamps EX-125
Tray with fixed clamps EX-125 For 36 Erlenmeyer flasks
%
Nabertherm ribbed Plate, Ceramic for L..5/LE6
• Tmax 1200 °C
• Dimensions 190 x 170 x 12.7 mm
• For models LE 4, LE 6, L 5, LT 5, LV 5, LVT 5
%
Esco Drawer Rack
For standard 2-inch High Boxes for UUS-363/480/597/714 Model with 3 Inner Doors Configuration
• Rack Dimension (WxDxH): 139x551x398 mm
• Can fit standard 130 x 130 x 50 mm (5.25” x 5.25” x 2”) boxes
• Has 7 shelves and contain 4 boxes per shelf. (7 x 4 configuration)
• Made of stainless steel and has handles.
• Weight: 7.5 Kg
%
Ohaus Rotor, Angle, 6x50ml RB, ID, Hi
Frontier rotors extend the functionality of Frontier centrifuges by increasing the number of tubes of varied types and sizes that can be used in conjunction with each of the centrifuge models. Easy to clean and operate, the rotors are durably constructed to withstand demanding centrifugation.

Compatible adapters and other accessories:
• Adapter, 1x15ml D17.5mm FA, 2/pk (30314892); Adapter, D17mm, 15ml Tubes x2 (30130893); Adapter, D18mm, 16ml Tubes x2 (30130892); Adapter, D26mm, 30ml Tubes x2 (30130891)
%
Miele APLW 017 upper basket
Upper basket with 121 unoccupied injector slots.
• Area of application: reprocessing laboratory glassware
• Only suitable for use on upper levels
• 200 x 490 mm chamber

Machine affiliation: Can be used for PLW 6111 devices.
%
Miele E 470 injector nozzle 2,5x90mm
For the optimum cleaning of the wash items.
• Area of application: reprocessing laboratory glassware
• For use in the mobile injector unit, Ø 2.5 x 90 mm.
• Suitable for mobile injector units, with screw connection
• Suitable for bottles, Erlenmeyer flasks and round bottomed flasks for example

Machine affiliation: Can be used in PG 8504, PG 8583, PG 8583 CD, PG 8593 and PLW 8617 devices.
%
Sigma 6-16KHS refrigerated benchtop centrifuge
The compactness of a benchtop centrifuge with the performance of a floor-standing centrifuge. The Sigma 6 16KHS refrigerated and heated centrifuge is suitable for a wide variety of routine and research applications. Along with high throughput with fixed-angle and swing-out rotors, it easily achieves RCF values up to 25,419 x g. Its key features are high versatility, an advanced user interface and outstanding reliability.

What makes the Sigma 6 16KHS refrigerated and heated centrifuge so attractive?
Particularly thanks to the ability to use large-capacity fixed-angle rotors with high RCF, the centrifuge covers a distinctly broader spectrum of applications compared to competitive units.

The Sigma 6 16KHS delivers precise separation results in all cases, whether blood pouches, petroleum flasks, microtiter and deepwell plates, or tubes and flasks from 0.2 ml to 1,000 ml.
It is widely used in microbiology and molecular biology, pharmaceutics, genomics, clinical diagnostics, bioproduction, cell culture labs and transfusion facilities. A total of twelve fixed-angle rotors and six swing-out rotors are available, along with numerous buckets and adapters – including many biosafe configurations. The Sigma 6 16KHS refrigerated and heated centrifuge has a precisely adjustable temperature range from –20°C to +60°C and is especially suitable for applications where the viscosity of specimens must be reduced.

The Sigma 6 16KHS features a clearly organised display. The patented Spincontrol S one-knob controller provides superior operating convenience and process reliability. Optimisation of separation runs and yields is supported by 60 programs with the option of making user-specific settings, as well as 30 profiles for use as acceleration or braking curves. Custom person-specific settings can be saved with password-protected access control. An extremely practical feature is the large program status display, visible from a distance, with a progress bar.

Applications: Food labs, Universities & colleges, Pharmaceutical labs, Environmental labs, Oil industry

Options: Sigma 6 16S unrefrigerated centrifuge, Sigma 6 16HS heated centrifuge, Sigma 6 16KS refrigerated centrifuge, inert gas port, Biosafe swing-out and fixed-angle rotors, RS 232 interface, DataSuite data documentation system
%
FOB5S/XL stand-alone lab sterilizer
FOB5 – STAND-ALONE LAB STERILIZER
Applications Food, Bio-pharmaceutical, Cosmetics, Microbiology, Packaging
Loads: Canned food, Sealed & unsealed containers, Large volume parenterals, Machine parts, Blood bags, Syringes, Tools, Wrapped tools, Culture media, Garments, Glassware
Processes: Sterilization
FOB5 Stand-alone Lab Sterilizer presents a great flexibility of use, ranging from quality assurance laboratories in pharmaceutical or food industries, to BSL3 – 4 laboratories in research centres and/or hospitals.
The possible application of FOB5 series of autoclaves can be:
• Microbiology and analytical labs.
• Research institutes and examination agencies.
• Bio-technologies and life sciences.
• Animal facility and clinical diagnostic labs.
• Pharmaceutical, food, chemistry industries, Q.C. labs.
• Agricultural, environmental and veterinary labs.
As all the autoclaves of Fedegari Lab Division, FOB5 has a modular design which allows a high flexibility of use for different loads and treatments. Please, click on the link “recommended kits” on the right to check out all the possible configurations referred to FOB5 series.
DESIGN AND TECHNICAL FEATURES
FOB5 autoclave series has a wide range of chamber volumes and come with both single and double vertical sliding door:
FOB5 series can be designed with a single or double stainless steel sealing flange (BIOSEAL), making it suitable for laboratory risk category L3 and L4 and operating theater. FOB5 Lab Sterilizers have two high-efficiency internal 316L stainless steel plates which can be used as heat-exchanger system for steam preheating, to cool the chamber temperature down by using cold water.
Moreover – as an option – these plates can be used to perform final drying.
FOB5 autoclaves are made of 316L stainless steel as well as pneumatic valves and hydraulic components.
Full and easy accessibility to technical area from the front and lateral side allows service and regular maintenance. External trolleys are fully compatible with FGW Fedegari Glassware Washer Series to assure integration between cleaning and sterilization processes in your laboratory.
FOB5 series is equipped with DCS20 process controller: 30 cycles easy to customize in a multi-user environment. Large touch-screen color display and interface for remote monitoring via Ethernet control. DCS20 process controller is fully validated and documented.
KEY BENEFITS
• Vertical position of filters avoiding frequent rupture.
• Thema4Lab process controller.
• GAMP5 compliance.
• High tech chamber and door construction.
• Suitable for BSL 3–4 laboratories.
• High process reliability.
• External trolleys fully compatible with FGW washers.
COMPLIANCE TO
• PED Directive 2014/68/UE – Pressure equipment
• Machine Directive Macchine 2006/42/EC
• EMC Directive 2014/35/UE
• LVD Directive 2006/95/UE
%
Nabertherm LT 9/12/C550 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.

Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type S (1200 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With lift door (LT)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation C550
• Solid state relays provide for lownoise operation

Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door

%
Kühner Tray with fixed clamps EX-150
Tray with fixed clamps EX-150 To load 36 x 150 ml Erlenmeyer flasks
%
Nabertherm ribbed Plate, Ceramic for L..9
• Tmax 1200 °C
• Dimensions 240 x 220 x 12.7 mm
• For models L 9, LT 9, LV 9, LVT 9, N 7
%
Esco Drawer Rack
For standard 2-inch High Boxes for UUS-363/480/597/714 Model with 5 Inner Doors Configuration
• Rack Dimension (WxDxH): 139x551x228mm
• Can fit standard 130 x 130 x 50 mm (5.25” x 5.25” x 2”) boxes
• Has 4 shelves and contain 4 boxes per shelf. (4 x 4 configuration)
• Made of stainless steel and has handles.
• Weight: 5 Kg
%
Ohaus Rotor, Angle, 30x15ml RB/FA, ID
Frontier rotors extend the functionality of Frontier centrifuges by increasing the number of tubes of varied types and sizes that can be used in conjunction with each of the centrifuge models. Easy to clean and operate, the rotors are durably constructed to withstand demanding centrifugation.

Compatible adapters and other accessories:
• Adapter, D11mm, 1.5/2.0ml Tubes x6 (30130886); Adapter, D13.5mm, 5ml Tubes x2 (30130890); Adapter, D13.5mm, 7ml Tubes x2 (30130889)
%
Miele APLW 018 upper basket
Upper basket with 121 + 24 unoccupied injector slots.
• Area of application: reprocessing laboratory glassware
• Only suitable for use on upper levels

Machine affiliation: Can be used for PLW 6111 devices.
%
Miele E 353 clamps for nozzle 4,0x160mm
Height-adjustable for optimum positioning of laboratory glassware on the nozzle.
• Area of application: reprocessing laboratory glassware
• Height adjustable locking
• Suitable for bottles, Erlenmeyer flasks and round bottomed flasks for example
• Suitable for injector nozzle E 351

Machine affiliation: Can be used in PG 8504, PG 8583, PG 8583 CD, PG 8593 devices, for E 351 injector nozzles.
%
Nabertherm L 9/11/B510 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.

Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type N (1100 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With flap door (L)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation B510 (5 programs with each 4 segments)
• Solid state relays provide for lownoise operation

Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door
%
Kühner Tray with fixed clamps EX-200
Tray with fixed clamps EX-200 To load 27 x 200 ml Erlenmeyer flasks
%
Nabertherm collecting Pan, Ceramic for L..3
• Tmax 1300 °C
• Dimensions 150 x 140 x 20 mm
• For models L 3, LT 3, LV 3, LVT 3