English
English
Magyar
Home
About us
Shop By Products
Shop By Brand
Contact us
blog
My Cart
Sign in
Public pricelist HUF
Prev
42
43
44
45
46
47
48
Next
Sort by
Relevance
Catalog price: High to Low
Catalog price: Low to High
Name - A to Z
Name - Z to A
Product Sequence Low to High
Product Sequence High to Low
All products
%
Kühner Tray with fixed clamps EX-300
Tray with fixed clamps EX-300 To load 21 x 300 ml Erlenmeyer flasks
Compare
%
Nabertherm collecting Pan, Ceramic for L..9
• Tmax 1300 °C
• Dimensions 240 x 220 x 20 mm
• For models L 9, LT 9, LV 9, LVT 9, N 7
Compare
%
Esco IQ/OQ Documentation for Esco ULT freezers
IQ/OQ protocol document is available for verifying that the equipment has been installed in accordance withinstallation specifications and is functioning and operating at the intended operational parameters.
Compare
%
Ohaus Rotor, Angle, 30x1.5/2.0ml, ID, Sealable
Frontier rotors extend the functionality of Frontier centrifuges by increasing the number of tubes of varied types and sizes that can be used in conjunction with each of the centrifuge models. Easy to clean and operate, the rotors are durably constructed to withstand demanding centrifugation.
Compatible adapters and other accessories:
• Adapter, D6mm, 0.2/0.4ml Tubes x6 (30130884); Adapter, D8mm, 0.5ml Tubes x6 (30130885)
Compare
%
Miele APLW 019/1 upper basket
Upper basket equipped with 121 APLW 047 injector nozzles.
• Area of application: reprocessing laboratory glassware
• Only suitable for use on upper levels
Machine affiliation: Can be used for PLW 6111 devices.
Compare
%
Miele A 2 cover net 1/2
For fixing delicate wash items.
• Area of application: reprocessing laboratory glassware
• Suitable for 1/2 inserts
• Plastic coated metal frame with plastic netting
• Size: 216 x 456 mm
Compare
%
Nabertherm L 9/12/C550 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.
Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type S (1200 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With flap door (L)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation C550
• Solid state relays provide for lownoise operation
Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door
Compare
%
Kühner Tray with fixed clamps EX-500
Tray with fixed clamps EX-500 To load 14 x 500 ml Erlenmeyer flasks
Compare
%
Nabertherm ribbed Plate, Ceramic for L..24
• Tmax 1200 °C
• Dimensions 340 x 270 x 12.7 mm
• For models L 24, LT 24
Compare
%
Ohaus Rotor, Angle, 12x1.5/2.0ml, ID
Frontier rotors extend the functionality of Frontier centrifuges by increasing the number of tubes of varied types and sizes that can be used in conjunction with each of the centrifuge models. Easy to clean and operate, the rotors are durably constructed to withstand demanding centrifugation.
Compatible adapters and other accessories:
• Adapter, 1x1.5ml for over16000xg, 6/pk (30314900); Adapter, D6mm, 0.2/0.4ml Tubes x6 (30130884); Adapter, D8mm, 0.5ml Tubes x6 (30130885)
Compare
%
Miele APLW 020 lower basket
Lower basket with 121 unoccupied injector slots for nozzles with Ø 2.5 mm.
• Area of application: reprocessing laboratory glassware
• Only suitable for use on the lowest level
Machine affiliation: Can be used for PLW 6111 devices.
Compare
%
Miele A 3 cover net 1/4
As cover for wash items in inserts.
• Area of application: reprocessing laboratory glassware
• Plastic coated metal frame with plastic netting
• Suitable for 1/4 inserts
• 206 x 206 mm
Compare
%
Nabertherm LT 15/11/B510 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.
Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type N (1100 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With lift door (LT)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation B510 (5 programs with each 4 segments)
• Solid state relays provide for lownoise operation
Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door
Compare
%
Kühner Tray with fixed clamps EX-1000
Tray with fixed clamps EX-1000 To load 9 x 1000 ml Erlenmeyer flasks
Compare
%
Nabertherm ribbed Plate, Ceramic for L..40
• Tmax 1200 °C
• Dimensions 490 x 310 x 12.7 mm
• For models L 40, LT 40
Compare
%
Ohaus Rotor, Angle, 4x8-w PCR Strip, ID
Frontier rotors extend the functionality of Frontier centrifuges by increasing the number of tubes of varied types and sizes that can be used in conjunction with each of the centrifuge models. Easy to clean and operate, the rotors are durably constructed to withstand demanding centrifugation.
Compatible adapters and other accessories:
• No adapters
Compare
%
Miele APLW 020/1 lower basket
Lower basket equipped with 121 APLW 047 injector nozzles.
• Area of application: reprocessing laboratory glassware
• Only suitable for use on the lowest level
Machine affiliation: Can be used for PLW 6111 devices.
Compare
%
Miele A 11/1 insert 1/1
For the gentle cleaning of delicate items by interrupting the spray jet.
• Area of application: reprocessing laboratory glassware
• With perforations 7 x 7 mm
• For use in upper and lower basket
Machine affiliation: Can be used in PG 8583, PG 8583 CD, PG 8593 devices.
Compare
%
Nabertherm LT 15/11/C550 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.
Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type N (1100 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With lift door (LT)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation C550
• Solid state relays provide for lownoise operation
Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door
Compare
%
Kühner Tray with fixed clamps EX-1500
Tray with fixed clamps EX-1500 To load 8 x 1500 ml Erlenmeyer flasks
Compare
Prev
42
43
44
45
46
47
48
Next