Ohaus Rotor Angle 24x1.5/2.0ml BIOSEALS V2
Frontier rotors extend the functionality of Frontier centrifuges by increasing the number of tubes of varied types and sizes that can be used in conjunction with each of the centrifuge models. Easy to clean and operate, the rotors are durably constructed to withstand demanding centrifugation.

Compatible adapters and other accessories:
• Adapter, D6mm, 0.2/0.4ml Tubes x6 (30130884); Adapter, D8mm, 0.5ml Tubes x6 (30130885)
%
Miele APLW 025/1 lower basket
Lower basket equipped with 12 APLW 056 injector nozzles and 12 APLW 052 injector nozzles.
• Area of application: reprocessing laboratory glassware
• Only suitable for use on the lowest level
• 230 x 490 mm usable space

Machine affiliation: Can be used for PLW 6111 devices.
%
Miele APH 590 ink cartridge
Ink cartridge for PRT 100 report printer.
%
Nabertherm LT 24/12/B510 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.

Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type S (1200 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With lift door (LT)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation B510 (5 programs with each 4 segments)
• Solid state relays provide for lownoise operation

Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door

%
Kühner Tray with fixed clamps F-125
Tray with fixed clamps F-125 To load 60 Erlenmeyer flasks with a volume of 125 ml
%
Miele APLW 026 lower basket
Lower basket with 20 unoccupied injector slots for nozzles.
• Area of application: reprocessing laboratory glassware
• Only suitable for use on the lowest level

Machine affiliation: Can be used for PLW 6111 devices.
%
Miele APH 591 paper roll
Paper roll for protocol printer APH 500 PRT100 and APH 510 PRT110
• 5 paper rolls per pack
• Width: 76 mm
%
Nabertherm LT 24/12/C550 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.

Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type S (1200 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With lift door (LT)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation C550
• Solid state relays provide for lownoise operation

Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door

%
Kühner Tray with fixed clamps F-150
Tray with fixed clamps F-150 To load 60 Erlenmeyer flasks with a volume of 150 ml
%
Miele APLW 026/1 lower basket
Lower basket equipped with 20 APLW 056 injector nozzles.
• Area of application: reprocessing laboratory glassware
• Only suitable for use on the lowest level

Machine affiliation: Can be used for PLW 6111 devices.
%
Miele XKM 3000LMed communication module
Communication module with Ethernet interface for connecting to a network.
• Ring memory for up to 30 process and 2 graphic protocols
• No other component is required for direct/network connection
• DHCP support for automatic setting of network parameters
• Transmission speed 10/100 Mbit/s
• Length of the connection cable: 1.5 m; extendable (The connector required for cable extension is included.)

Machine affiliation: Can be used for PG 8583, PG 8583 CD, PG 8593 devices.
%
Nabertherm L 24/11/B510 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.

Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type N (1100 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With flap door (L)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation B510 (5 programs with each 4 segments)
• Solid state relays provide for lownoise operation

Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door

%
Kühner Tray with fixed clamps F-200
Tray with fixed clamps F-200 To load 40 Erlenmeyer flasks with a volume of 200 ml
%
Miele APLW 027 lower basket
Lower basket with 16 unoccupied injector slots for nozzles.
• Area of application: reprocessing laboratory glassware
• Only suitable for use on the lowest level

Machine affiliation: Can be used for PLW 6111 devices.
%
Miele XKM RS 232 10 Med communication module
Communication modulewith serial interface (RS232) for connection to a printer.
• Ring memory for max. 25 process reports
• Difference between short and long report
• Transfer speed: max. 38 kBit/s
• Length of supply lead: 1.5 m; extension up to 15 m possible


Machine affiliation: Can be used for PG 8583, PG 8583 CD, PG 8593 devices.
%
Nabertherm L 24/11/C550 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.

Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type N (1100 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With flap door (L)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation C550
• Solid state relays provide for lownoise operation

Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door

%
Kühner Tray with fixed clamps F-250
Tray with fixed clamps F-250 To load 40 Erlenmeyer flasks with a volume of 250 ml
%
Miele APLW 028 lower basket
Lower basket with 27 unoccupied injector slots for nozzles.
• Area of application: reprocessing laboratory glassware
• Only suitable for use on the lowest level

Machine affiliation: Can be used for PLW 6111 devices.
%
Nabertherm L 24/12/B510 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.

Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type S (1200 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With flap door (L)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation B510 (5 programs with each 4 segments)
• Solid state relays provide for lownoise operation

Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door

%
Kühner Tray with fixed clamps F-300
Tray with fixed clamps F-300 To load 30 Erlenmeyer flasks with a volume of 300 ml