Nabertherm lid for Rectangular Saggar
• Made of ceramic
• Dimensions 110 x 75 x 5 mm
• For rectangular saggar (699000279)
%
Ohaus Rotor Swing out 4x750ml ID Sealable
Frontier rotors extend the functionality of Frontier centrifuges by increasing the number of tubes of varied types and sizes that can be used in conjunction with each of the centrifuge models. Easy to clean and operate, the rotors are durably constructed to withstand demanding centrifugation.

Compatible adapters and other accessories:
• Bucket 1x750ml D99mm FB x2 V1 (30602502)*All racks are used with bucket 30602502 only; Lid Assembly for Bucket 30602502 PC 2x (30553122); O-Ring for bucket 30602502 NBR 10x (30553123); Rack 1x500ml D96mm FA x2 (30553124); Rack 1x250ml D62mm FB x2 V1 (30553125); Rack 1x175/225ml D61mm FA x2 (30553126); Rack 3x100ml D41mm RB x2 (30553127); Rack 5x50ml D29mm FA x2 (30553128); Rack 5x50ml D29mm FAw/R x2 (30553129); Rack 5x50ml D29mm FAw/R x2 (30553130); Rack 7x50ml D29mm RB x2 (30553131); Rack 8x30ml D26mm RB x2 (30553132); Rack 14x15ml D17mm FA x2 (30553133); Rack 17x15ml D17mm FA x2 (30553134); Rack 18x15ml D17mm RB x2 (30553135); Rack 21x10ml D16mm RB x2 (30553136); Rack 32x7ml D13mm RB x2 (30553138); Rack 27x1.8/7ml D13mm Vac/Sar x2 (30553139); Rack 18x4/10ml D16mm Vac/Sar x2 (30553140); Rack 38x1.1/1.4ml D8mm Sar x2 (30559377); Bucket MTP x2 V1 (30553104); Holder removing aid for Bucket (30553105); Lid Assembly for bucket 30553104 PC x2 (30553117); O-Ring for bucket 30553104 SIL x2 (30553118); Bucket MTP x2 V2 (30553119)
%
Miele APLW 024/2 lower basket
Lower basket equipped with 32 APLW 051 injector nozzles and 10 APLW 055 injector nozzles.
• Area of application: reprocessing laboratory glassware
• Only suitable for use on the lowest level

Machine affiliation: Can be used for PLW 6111 devices.
%
Julabo PRESTO W92ttx Highly dynamic temperature control system
Advanced control technology and a small bath fluid reservoir enable highly dynamic temperature control systems to achieve rapid heat-up and cool-down. This gives you the ability to handle difficult temperature challenges quickly.
The PRESTO® systems are designed for precise temperature control as well as rapid temperature changes, making them ideal for reactor vessels, material stress tests, or temperature simulations. These instruments cover a working temperature of -92 to +250 °C with high cooling and heating capacity.
• USB connection
• For highly precise, external temperature applications
• Rapid heating and cooling
• Wide working temperature ranges without changing fluids
• Highest performance with small footprint
• Space-saving design optimizes space utilization in your lab
• Ethernet interface
• SD-Card slot
• RS232 / RS485 (optional) / Profibus DP (optional)
• Connections for alarm-output, Pt100 external sensor and standby-input
• Removable ventilation grid
• Highly precise ICC cascade temperature control
• Electronic level indication
• Integrated programmer
• Unsurpassed power and efficiency
• Space optimized design creates more room directly next to the units
• External Pt100 sensor connection
%
Nabertherm L 15/12/C550 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.

Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type S (1200 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With flap door (L)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation C550
• Solid state relays provide for lownoise operation

Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door

%
Kühner Tray with fixed clamps F-25
Tray with fixed clamps F-25 To load 153 Erlenmeyer flasks with a volume of 25 ml
%
Ohaus Rotor Angle 4x500ml ID
Frontier rotors extend the functionality of Frontier centrifuges by increasing the number of tubes of varied types and sizes that can be used in conjunction with each of the centrifuge models. Easy to clean and operate, the rotors are durably constructed to withstand demanding centrifugation.

Compatible adapters and other accessories:
• Adapter 1x250ml D60.5mm FA x2 (30559416)); Adapter 1x175/225 ml D61.5mm FA x2 (30559417); Adapter 1x50ml D29.5mm FA x2 (30559419); Adapter 3x50ml D29mm RB x2 (30559420); Adapter 4x30ml D25.5mm RB x2 (30559421); Adapter 6x15ml D17mm FA x2 (30559422); Adapter 1x250ml D61.5mm FB x2 (30564850)
%
Miele APLW 024/3 lower basket
Lower basket equipped with 30 APLW 066 injector nozzles and 12 APLW 067 injector nozzles.
• Area of application: reprocessing laboratory glassware
• Only suitable for use on the lowest level

Machine affiliation: Can be used for PLW 6111 devices.
%
Ohaus Rotor Angle 45° 24x1.5/2.0ml ID BIOSEALS
Frontier rotors extend the functionality of Frontier centrifuges by increasing the number of tubes of varied types and sizes that can be used in conjunction with each of the centrifuge models. Easy to clean and operate, the rotors are durably constructed to withstand demanding centrifugation.

Compatible adapters and other accessories:
• Adapter, D6mm, 0.2/0.4ml Tubes x6 (30130884); Adapter, D8mm, 0.5ml Tubes x6 (30130885)
%
Nabertherm LT 24/11/B510 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.

Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type N (1100 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With lift door (LT)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation B510 (5 programs with each 4 segments)
• Solid state relays provide for lownoise operation

Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door

%
Kühner Tray with fixed clamps F-50
Tray with fixed clamps F-50 To load 100 Erlenmeyer flasks with a volume of 50 ml
%
Miele APLW 025 lower basket
Lower basket with 24 unoccupied injector slots for nozzles.
• Area of application: reprocessing laboratory glassware
• Only suitable for use on the lowest level
• 230 x 490 mm usable space

Machine affiliation: Can be used for PLW 6111 devices.
%
Nabertherm LT 24/11/C550 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.

Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type N (1100 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With lift door (LT)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation C550
• Solid state relays provide for lownoise operation

Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door

%
Kühner Tray with fixed clamps F-100
Tray with fixed clamps F-100 To load 74 Erlenmeyer flasks with a volume of 100 ml
%
Ohaus Rotor Angle 24x1.5/2.0ml BIOSEALS V2
Frontier rotors extend the functionality of Frontier centrifuges by increasing the number of tubes of varied types and sizes that can be used in conjunction with each of the centrifuge models. Easy to clean and operate, the rotors are durably constructed to withstand demanding centrifugation.

Compatible adapters and other accessories:
• Adapter, D6mm, 0.2/0.4ml Tubes x6 (30130884); Adapter, D8mm, 0.5ml Tubes x6 (30130885)
%
Miele APLW 025/1 lower basket
Lower basket equipped with 12 APLW 056 injector nozzles and 12 APLW 052 injector nozzles.
• Area of application: reprocessing laboratory glassware
• Only suitable for use on the lowest level
• 230 x 490 mm usable space

Machine affiliation: Can be used for PLW 6111 devices.
%
Nabertherm LT 24/12/B510 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.

Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type S (1200 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With lift door (LT)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation B510 (5 programs with each 4 segments)
• Solid state relays provide for lownoise operation

Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door

%
Kühner Tray with fixed clamps F-125
Tray with fixed clamps F-125 To load 60 Erlenmeyer flasks with a volume of 125 ml
%
Miele APLW 026 lower basket
Lower basket with 20 unoccupied injector slots for nozzles.
• Area of application: reprocessing laboratory glassware
• Only suitable for use on the lowest level

Machine affiliation: Can be used for PLW 6111 devices.
%
Nabertherm LT 24/12/C550 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.

Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type S (1200 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With lift door (LT)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation C550
• Solid state relays provide for lownoise operation

Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door