English
English
Magyar
Home
About us
Shop By Products
Shop By Brand
Contact us
blog
My Cart
Sign in
Public pricelist HUF
Prev
47
48
49
50
51
52
53
Next
Sort by
Relevance
Catalog price: High to Low
Catalog price: Low to High
Name - A to Z
Name - Z to A
Product Sequence Low to High
Product Sequence High to Low
All products
All Products
Brand
Bandelin
Bimos
Binder
Düperthal
Esco
Fedegari
Fumex
Heidolph
HP Labortechnik
Julabo
Kirsch
Kühner
Liebherr
Miele
Nabertherm
Ohaus
Sigma
Stakpure
Vacuubrand
Waldner
Products
Autoclaves
Bioreactors
Safety storage cabinets
Centrifuges
CO₂ incubators
Distimatic automatic module
Documentation software
Extraction arms
Fluid aspiration systems
Heating circulators
Refrigerated / heating circulators
Incubators
Climate chambers
Laboratory freezers
Laboratory dishwashers
Laboratory refrigerators
Combined laboratory refrigerator-freezers
Laboratory chairs
Laboratory furniture
Laminar flow cabinets
Laboratory furnaces
Magnetic stirrers
Balances
Microbiological safety cabinets
Moisture analyzers
Growth chambers
Peristaltic pumps
Professional shakers
Shakers
Rotary evaporators
Overhead stirrers
Drying chambers and heating chambers
Test chambers
Ultrasonic baths
Ultrasonic cell disruptor
Ultrasonic baths
Ultra low temperature freezers
Vacuum drying chambers
Vacuum networks
Vacuum gauges and controllers
Vacuum pumps
Fume cupboards
Water baths
Water purification systems
%
Kühner Tray with fixed clamps F-4000
Tray with fixed clamps F-4000 For 5 Erlenmeyer flasks with 4000 ml volume
Compare
%
Miele APLW 34 lid
Lid height 250 mm, for securing delicate wash items.
• Area of application: reprocessing laboratory glassware
Machine affiliation: Can be used for PLW 6111 devices.
Compare
%
Nabertherm L 40/12/B510 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.
Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type S (1200 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With flap door (L)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation B510 (5 programs with each 4 segments)
• Solid state relays provide for lownoise operation
Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door
Compare
%
Kühner Tray with fixed clamps F-5000
Tray with fixed clamps F-5000 With 4 clamps
Compare
%
Miele APLW 035 lid
Lid height 175 mm, for securing delicate wash items.
• Area of application: reprocessing laboratory glassware
Machine affiliation: Can be used for PLW 6111 devices.
Compare
%
Nabertherm L 40/12/C550 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.
Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type S (1200 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With flap door (L)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation C550
• Solid state relays provide for lownoise operation
Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door
Compare
%
Kühner Tray with fixed clamps F-6000
Tray with fixed clamps F-6000 To load 3 x 6000 ml Erlenmeyer flasks
Compare
%
Miele APLW 036 lid
Lid height 45 mm, for securing delicate wash items.
• Area of application: reprocessing laboratory glassware
Machine affiliation: Can be used for PLW 6111 devices.
Compare
%
Liebherr SFPvh 6501 laboratory freezer
Laboratory refrigerators and freezers are expected to offer the highest level of safety and reliability. The precise electronic control, forced-air cooling system, and highly efficient insulation work together to achieve outstanding energy efficiency, keeping operating costs low and ensuring environmental protection. The advanced components and precise regulation ensure optimal storage conditions for materials over the long term.
Product Features
• Ventilated cooling system
• Cooling technology: NoFrost
• Temperature range: -9 °C to -35 °C
Simple Operation
• Built-in handle spanning the full height of the door
• 2.4" color electronic control panel with touch & swipe functionality
• Easy-to-clean stainless-steel interior
• Flush-mounted internal lighting (vertical, full-height side LED lighting)
Safety and Reliability
• Maximum temperature stability: ±5 °C
• VCC variable speed compressor
Thanks to variable-speed compressors, the appropriate power is always available, which reduces energy consumption while providing higher temperature stability.
• Optical and acoustic alert in case of malfunction
• SafetyDevice: prevents the temperature from dropping below +2 °C, preventing freezing
• PT1000 product temperature sensor
In addition to the built-in control sensor, a secondary temperature sensor is available to measure the simulated product temperature. The value measured by the product temperature sensor can be displayed on the screen. This value is calibratable, and the upper/lower alarm thresholds are based on this value for safer storage based on actual product temperatures.
• Power outage alarm
In case of a power outage, the built-in battery maintains power for at least twelve hours and immediately triggers an audible and visual alarm. An additional display indicates the start of the power failure and the maximum temperature reached.
• LightAlarm
If uncontrolled temperature rise, a door left open, or any other problem occurs, the internal lighting of the unit will start flashing.
• Alarm history: Simple quality control
The last 10 alarms are logged with important data (such as date or maximum temperature) to assist in the final quality assessment of stored goods.
• Built-in data logger: Trackable for years
Full traceability independent of monitoring systems, with logging of the temperature profile, alarm history, and service information for up to 5 years. Data can be retrieved via USB port.
• The door automatically closes when opened at less than a 90° angle
• Probe access: 1 x Ø 12 mm
• Electronic lock system: Protection against unauthorized access with PIN code or remote lock/unlock control
• SmartLock: The door automatically locks in case of a temperature alarm, which can only be unlocked by authorized personnel
• Long lifespan
Compliance and Documentation
• DIN 13277 and IEC 61010-2-011 compliance
Liebherr laboratory and pharmaceutical refrigeration units meet all the characteristics and performance criteria necessary for full compliance with the DIN 13277 standard. The DIN 13277 defines the requirements and testing guidelines for refrigeration and deep-freeze equipment used in laboratories and for pharmaceutical storage.
• Temperature distribution and consistency according to IEC 60068-3
• Safety according to IEC 61010-2-011
• Temperature setting (calibration)
• Logging of minimum/maximum temperature values
• Integrated connectivity (LAN or WiFi for BMS or SmartMonitoring system)
Technical Data
• Gross/net capacity: 614/480 L
• External dimensions (W/D/H): 697/867/2135 mm
• Internal dimensions (W/D/H): 489/638/1470 mm
• White stainless steel exterior
• Door/Cover material: Steel
• Number of adjustable shelves: 4
• Plastic-coated wire shelves
• Usable shelf size (W/D): 570/788 mm
• Shelf load capacity: 60 kg
• Door opening: Right-hand reversible
• Castors with arrestor at the front, fixed castors at the rear
• Gross/net weight: 150/132 kg
• Energy consumption/year: 702 kWh
• Ambient temperature: +10 °C to +35 °C
• Heat emission: 875 kJ/h
• Refrigerant: R 290
• Noise level: 60 dB(A)
• Frequency/voltage: 50/60 Hz / 220-240 V~
Compare
%
FGW350 lab glassware washer
FGW – LAB GLASSWARE WASHER
THE COST-EFFECTIVE CHOICE.
LAB GLASSWARE WASHER.
Applications: Food, Bio-Pharmaceutical, Cosmetics, Microbiology
Loads: Tools, Glassware
Processes: Washing
Fedegari Lab Division latest innovation is a Lab Glassware Washer that capitalizes the experience done with FOWS-series of washers in the pharmaceutical industry.
The power of steam: a cost-effective cleaning
The new FGW Lab Glassware Washer uses a steam generator to improve washing performances. Steam has an optimized emollient effect on greasy and sticky dirt. In addition, steam is able to access hard-to-reach areas and therefore clean thoroughly. Moreover the use of steam can significantly reduces operating costs: this really eco-friendly solution allows to minimize the need of detergents as well as water consumption, lowering the running costs per cycle.
A conductivity meter placed on the FGW drain is capable to detect the water purity, helping to terminate the process as soon as the desired set-point is reached thus further reducing water and other utilities consumption of the washer.
The cleaning process is constantly supervised: dedicated probes monitoring the temperature of the air/water and of the steam in chamber. Fedegari Glassware Washer has an internal LED lamp that remains operative during the whole cycle: in case of alarm evident signals are displayed by color change.
DESIGN AND TECHNICAL FEAUTURES
The piping, as any other equipment manufactured by Fedegari, has a rigorous sanitary finishing. The FGW glassware washer is equipped with custom-made and modular internal trays, connected to the hydraulic system. The external trolleys are fully compatible with those of the FOB5 autoclave.
KEY BENEFITS
• Steam improves washing performances.
• Thema4Lab.
• Steam as Eco-friendly solution.
• Energy saving function.
• Customizable internal rack.
• Trolleys and trays fully compatible with FOB5 series.
• Sanitary components and CIP to ensure a perfect washing.
• GLP compliance.
COMPLIANCE TO
• PED Directive 2014/68/UE – Pressure equipment**
• Machine Directive Macchine 2006/42/EC
• EMC Directive 2014/35/UE
• LVD Directive 2006/95/UE
Compare
%
Nabertherm LT 60/11/B510 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.
Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type N (1100 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With lift door (LT)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation B510 (5 programs with each 4 segments)
• Solid state relays provide for lownoise operation
Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door
Compare
%
Miele APLW 037 protective grilles
Protective grilles height-adjustable, for securing delicate wash items.
• Area of application: reprocessing laboratory glassware
Machine affiliation: Can be used for PLW 6111 devices.
Compare
%
Liebherr SFPvg 6501 laboratory freezer
Laboratory refrigerators and freezers are expected to offer the highest level of safety and reliability. The precise electronic control, forced-air cooling system, and highly efficient insulation work together to achieve outstanding energy efficiency, keeping operating costs low and ensuring environmental protection. The advanced components and precise regulation ensure optimal storage conditions for materials over the long term.
Product Features
Simple Operation
User-friendly solutions for daily use
• Built-in handle spanning the full height of the door
• Monochrome, 3-button electronic control interface
• Easy-to-clean stainless steel interior
• Door stays open at an angle greater than 90°
• Flush-mounted internal ceiling LED lighting
Compliance and Documentation
Built-in safety features to protect sensitive materials
• Temperature adjustment (calibration)
• Logging of minimum/maximum temperature values
The recorded minimum and maximum internal temperatures are saved by the device and can be easily viewed on the display
• Connectivity upgradeable (LAN or WiFi for BMS or SmartMonitoring system)
• Compliance with standards: IEC 60068-3, IEC 61010-2-011
Safety and Reliability
Reliable storage thanks to consistent cooling performance, even under extreme environmental temperature conditions
• Temperature stability: up to ±3 °C for refrigerators / ±5 °C for freezers
• Alarm relay
Alarm forwarding to the monitoring system / never miss any deviation
• Door automatically closes when opened at less than a 90° angle
• Probe access port: 10 mm diameter
• Mechanical door lock
• Long lifespan
Technical Data
• Gross/net capacity: 614/480 L
• External dimensions (W/D/H): 697/867/2135 mm
• Internal dimensions (W/D/H): 489/638/1470 mm
• Energy consumption/year: 774 kWh
• Ambient temperature: +10 °C to +35 °C
• Heat emission: 975 kJ/h
• Refrigerant: R 290
• Noise level: 60 dB(A)
• Frequency / voltage: 50 Hz / 220-240 V~
• Ventilated cooling system
• Automatic defrost
• Temperature range: -9 °C to -30 °C
• Exterior casing/colour: steel/white
• Interior lining: Chrome-nickel steel (1.4301 / AISI 304)
• Door/Cover material: steel
• Network connectivity via SmartModule / retrofittable
• WLAN/LAN connection: optional
• Number of adjustable shelves: 4
• Shelf material: steel with plastic coating
• Usable shelf size (W/D): 480/638 mm
• Shelf load capacity: 60 kg
• Castors with arrestor at the front, fixed castors at the rear
• Probe access: 1 x Ø 12 mm
• Door opening direction: right, reversible
• Gross/net weight: 131/113 kg
Compare
%
Nabertherm LT 60/11/C550 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.
Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type N (1100 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With lift door (LT)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation C550
• Solid state relays provide for lownoise operation
Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door
Compare
%
Miele APLW 038 insert
Insert for the optimum loading of wide-necked Erlenmeyer flasks & measuring cylinders.
• Area of application: reprocessing laboratory glassware
• Equipped with 14 spring hooks, 175 mm & 14 105 mm height
Compare
%
Liebherr SFPvh 8401 laboratory freezer
Laboratory refrigerators and freezers are expected to offer the highest level of safety and reliability. The precise electronic control, forced-air cooling system, and highly efficient insulation work together to achieve outstanding energy efficiency, keeping operating costs low and ensuring environmental protection. The advanced components and precise regulation ensure optimal storage conditions for materials over the long term.
Product Features
Simple Operation
User-friendly solutions for daily use
• Built-in handle spanning the full height of the door
• 2.4” color electronic control interface with touch & swipe functionality
• Easy-to-clean stainless steel interior
• Flush-mounted internal side LED lighting (vertical, full height)
Safety and Reliability
• Temperature stability: up to ±5 °C
• VCC variable speed compressor
Thanks to variable speed compressors, the right performance is always available. This results in reduced energy consumption and provides greater temperature stability.
• Visual and audible alarm for malfunctions
• SafetyDevice: prevents the temperature from dropping below +2 °C and freezing
• PT1000 product temperature sensor
In addition to the built-in control sensor, a secondary temperature sensor is available to measure simulated product temperature. The value measured by the product temperature sensor can be displayed on the screen. It is calibratable, and the upper/lower thresholds of the device's alarm functions are based on this value for safer storage based on real product temperatures.
Power Failure Alarm
In case of a power failure, the built-in battery maintains power for at least twelve hours and immediately triggers an audible and visual alarm. Additional indication of when the power outage began and the maximum temperature reached.
• LightAlarm
If there is uncontrolled temperature rise, an open door, or another issue, the internal lighting of the unit will start flashing.
• Alarm History: Quality control made easy
Logs the key data of the last 10 alarms (e.g., date or maximum temperature) for final quality assessment of stored goods.
• Built-in data logger: trackable for years
Complete traceability independent of monitoring systems, with logging of temperature profiles, alarm history, and service information for up to 5 years. Stored data can be read via USB port.
• The door automatically closes when opened at an angle less than 90°
• Probe access port: 1 x Ø 12 mm
• Electronic locking system: protection against unauthorized access with PIN code or remote locking/unlocking
• SmartLock: the door automatically locks in case of a temperature alarm and can only be unlocked by authorized personnel
• Long lifespan
Compliance and Documentation
• Compliance with DIN 13277 and IEC 61010-2-011
Liebherr's laboratory and pharmaceutical refrigeration units meet all the characteristics and performance criteria required for full compliance with the DIN 13277 standard, which defines the requirements and testing procedures for cooling and freezing equipment used in laboratories and for drug storage.
• Compliance with IEC 60068-3 standard for temperature distribution and consistency
• Compliance with IEC 61010-2-011 standard for safety
• Temperature setting (calibration)
• Logging of minimum/maximum temperature values
• Integrated connectivity (LAN or WiFi for BMS or SmartMonitoring system)
Technical Data
• Gross/net capacity: 871/702 L
• External dimensions (W/D/H): 787/1017/2135 mm
• Internal dimensions (W/D/H): 579/788/1470 mm
• White, stainless steel external casing
• Door/Cover material: steel
• Adjustable shelves: 4
• Plastic-coated racks
• Usable shelf size (W/D): 570 / 788 mm
• Shelf load capacity: 60 kg
• Door opening: right, reversible
• Castors with arrestor at the front, fixed castors at the rear
• Gross/net weight: 167/149 kg
• Energy consumption/year: 748 kWh
• Ambient temperature: +10 °C to +35 °C
• Heat emission: 935 kJ/h
• Refrigerant: R 290
• Noise level: 60 dB(A)
• Frequency / voltage: 50/60 Hz / 220-240 V~
Compare
%
FGW500 lab glassware washer
FGW – LAB GLASSWARE WASHER
THE COST-EFFECTIVE CHOICE.
LAB GLASSWARE WASHER.
Applications: Food, Bio-Pharmaceutical, Cosmetics, Microbiology
Loads: Tools, Glassware
Processes: Washing
Fedegari Lab Division latest innovation is a Lab Glassware Washer that capitalizes the experience done with FOWS-series of washers in the pharmaceutical industry.
The power of steam: a cost-effective cleaning
The new FGW Lab Glassware Washer uses a steam generator to improve washing performances. Steam has an optimized emollient effect on greasy and sticky dirt. In addition, steam is able to access hard-to-reach areas and therefore clean thoroughly. Moreover the use of steam can significantly reduces operating costs: this really eco-friendly solution allows to minimize the need of detergents as well as water consumption, lowering the running costs per cycle.
A conductivity meter placed on the FGW drain is capable to detect the water purity, helping to terminate the process as soon as the desired set-point is reached thus further reducing water and other utilities consumption of the washer.
The cleaning process is constantly supervised: dedicated probes monitoring the temperature of the air/water and of the steam in chamber. Fedegari Glassware Washer has an internal LED lamp that remains operative during the whole cycle: in case of alarm evident signals are displayed by color change.
DESIGN AND TECHNICAL FEAUTURES
The piping, as any other equipment manufactured by Fedegari, has a rigorous sanitary finishing. The FGW glassware washer is equipped with custom-made and modular internal trays, connected to the hydraulic system. The external trolleys are fully compatible with those of the FOB5 autoclave.
KEY BENEFITS
• Steam improves washing performances.
• Thema4Lab.
• Steam as Eco-friendly solution.
• Energy saving function.
• Customizable internal rack.
• Trolleys and trays fully compatible with FOB5 series.
• Sanitary components and CIP to ensure a perfect washing.
• GLP compliance.
COMPLIANCE TO
• PED Directive 2014/68/UE – Pressure equipment**
• Machine Directive Macchine 2006/42/EC
• EMC Directive 2014/35/UE
• LVD Directive 2006/95/UE
Compare
%
Nabertherm LT 60/12/B510 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.
Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type S (1200 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With lift door (LT)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation B510 (5 programs with each 4 segments)
• Solid state relays provide for lownoise operation
Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door
Compare
%
Miele APLW 039 insert
Insert for optimum loading of half petri dishes.
• Area of application: reprocessing laboratory glassware
• Suitable for 26 half petri dishes
• Spacing between the holders 24 mm
Compare
%
Liebherr SFPvg 8401 laboratory freezer
Laboratory refrigerators and freezers are expected to offer the highest level of safety and reliability. The precise electronic control, forced-air cooling system, and highly efficient insulation combine to deliver outstanding energy efficiency, keeping operating costs low while protecting the environment. The advanced components and precise regulation ensure optimal storage conditions for materials over the long term.
Product Features
Simple Operation
User-friendly solutions for daily use
• Built-in handle spanning the full height of the door
• Monochrome, 3-button electronic control interface
• Easy-to-clean stainless steel interior
• The door stays open at an angle greater than 90°
• Flush-mounted internal ceiling LED lighting
Compliance and Documentation
Built-in safety features to protect sensitive materials
• Temperature setting (calibration)
• Recording of minimum/maximum temperature values
The set minimum and maximum internal temperatures are saved by the device and can be easily viewed on the display
• Connectivity via retrofit (LAN or WiFi for BMS or SmartMonitoring system)
• Standard compliance: IEC 60068-3, IEC 61010-2-011
Safety and Reliability
Reliable storage due to consistent cooling performance, even under extreme environmental temperature conditions
• Temperature stability: up to ±3 °C for Refrigerator / ±5 °C for Freezer
• Alarm relay
Alarm signals are transmitted to the monitoring system, ensuring no deviations go unnoticed
• The door automatically closes when opened less than 90°
• Probe access port: 10 mm diameter
• Mechanical door lock
• Long lifespan
Technical Data
• Gross/net capacity: 871/702 liters
• External dimensions (W/D/H): 787/1017/2135 mm
• Internal dimensions (W/D/H): 489/638/1470 mm
• Energy consumption per year: 870 kWh
• Ambient temperature: +10 °C to +35 °C
• Heat emission: 1110 kJ/h
• Refrigerant: R 290
• Noise level: 60 dB(A)
• Frequency / voltage: 50 Hz / 220-240 V~
• Ventilated cooling system
• Automatic defrost
• Temperature range: -9°C to -30°C
• External casing/color: steel / white
• Interior casing: Chrome-nickel steel (1.4301 / AISI 304)
• Door/Cover material: steel
• Network connectivity option: SmartModule / retrofittable
• WLAN/LAN connectivity: optional
• Number of adjustable shelves: 4
• Shelves material: steel with plastic coating
• Usable shelf size (W/D): 480 / 638 mm
• Shelf load capacity: 60 kg
• Castors with arrestor at the front, fixed castors at the rear
• Probe access port: 1 x Ø 12 mm
• Door opening direction: right, reversible
• Gross/net weight: 166/149 kg