FVA3/A1 vertical lab sterilizer

  • Max. operating pressure (bar)
  • Overall dimensions (w x d x h in mm)
  • Chamber volume (liter)
  • Working volume (liter)
  • Loading height (mm)
  • Interior dimensions: (Ø x h) (mm)
  • Empty weight (kg)
  • Max. operating temperature (°C)

This combination does not exist.

Enquiry

VA/A1 – VERTICAL LAB STERILIZER
WHEN TECHNOLOGY AND DESIGN COME TOGETHER.
• Applications: Food, Bio-Pharmaceutical, Cosmetics, Microbiology, Packaging
• Loads: Canned food, Sealed & unsealed containers, Large volume parenterals, Machine parts, Blood bags, Syringes, Tools, Wrapped tools, Culture media, Garments, Glassware
• Processes: Sterilization
• Useful chamber capacity: 140 liter
The FVA/A1 Vertical Lab Sterilizer combines design with excellent performances and simplicity of use.
The automatic vertical sterilizer FVA/A1 has been specifically designed and developed to meet the most demanding application requirements in many different sectors, from universities to quality control laboratories in pharma, food or cosmetics industrial sectors.
FVA/A1 autoclave is the perfect solution for highly specialized fields and challenging customers worldwide that demand exclusive, reproducible and validated processes. These sterilizers have been designed with ergonomical features for easy handling and daily use.
The basic version of FVA/A1 can be used for standard processes and is easy to configure, thanks to its conceptual design and modular construction with exclusive optional kits. Please, click on the link “recommended kit” to check out all possible configurations referred to FVA/A1 series.
DESIGN & TECHNICAL FEATURES
FVA/A1 lab sterilizers are equipped with 316L stainless steel chamber and lid with automatic independent operation and control. The access to the technical area is assured by a wide front door with a special safety lock for easy maintenance.
The exclusive horizontal swivelling lid has a patented seal with compressed air system for perfect airtight, safety and easy maintenance.
An internal heat exchanger, made of 316L stainless steel and a fan for rapid cooling system can be integrated in the lid. An internal heat exchanger, made of 316L stainless steel and a fan for rapid cooling system can be integrated in the lid. The DCS 20 process controller allows fully programmability: 30 cycles easy to customize in a multi-user environment and an interface for remote monitoring via Ethernet protocol. The operating software is fully validated and documented.
KEY BENEFITS
• Satisfies the most rigid requirements of safety and quality according to international standards.
• New materials providing chemical inert insulation and both thermal and acoustic: smoother, quieter and safer operations.
• Energy saving system.
• Functional and attractive design.
• High level of programming and control versatility.
• Innovative and unique modular design.
• Ideal positioning of operator panel and printer.
• Optimized loading height from floor.
• GLP compliance
COMPLIANCE TO
• PED Directive 2014/68/UE – Pressure equipment
• Machine Directive Macchine 2006/42/EC
• EMC Directive 2014/35/UE
• LVD Directive 2006/95/UE

VA/A1 – VERTICAL LAB STERILIZER
WHEN TECHNOLOGY AND DESIGN COME TOGETHER.
• Applications: Food, Bio-Pharmaceutical, Cosmetics, Microbiology, Packaging
• Loads: Canned food, Sealed & unsealed containers, Large volume parenterals, Machine parts, Blood bags, Syringes, Tools, Wrapped tools, Culture media, Garments, Glassware
• Processes: Sterilization
• Useful chamber capacity: 140 liter
The FVA/A1 Vertical Lab Sterilizer combines design with excellent performances and simplicity of use.
The automatic vertical sterilizer FVA/A1 has been specifically designed and developed to meet the most demanding application requirements in many different sectors, from universities to quality control laboratories in pharma, food or cosmetics industrial sectors.
FVA/A1 autoclave is the perfect solution for highly specialized fields and challenging customers worldwide that demand exclusive, reproducible and validated processes. These sterilizers have been designed with ergonomical features for easy handling and daily use.
The basic version of FVA/A1 can be used for standard processes and is easy to configure, thanks to its conceptual design and modular construction with exclusive optional kits. Please, click on the link “recommended kit” to check out all possible configurations referred to FVA/A1 series.
DESIGN & TECHNICAL FEATURES
FVA/A1 lab sterilizers are equipped with 316L stainless steel chamber and lid with automatic independent operation and control. The access to the technical area is assured by a wide front door with a special safety lock for easy maintenance.
The exclusive horizontal swivelling lid has a patented seal with compressed air system for perfect airtight, safety and easy maintenance.
An internal heat exchanger, made of 316L stainless steel and a fan for rapid cooling system can be integrated in the lid. An internal heat exchanger, made of 316L stainless steel and a fan for rapid cooling system can be integrated in the lid. The DCS 20 process controller allows fully programmability: 30 cycles easy to customize in a multi-user environment and an interface for remote monitoring via Ethernet protocol. The operating software is fully validated and documented.
KEY BENEFITS
• Satisfies the most rigid requirements of safety and quality according to international standards.
• New materials providing chemical inert insulation and both thermal and acoustic: smoother, quieter and safer operations.
• Energy saving system.
• Functional and attractive design.
• High level of programming and control versatility.
• Innovative and unique modular design.
• Ideal positioning of operator panel and printer.
• Optimized loading height from floor.
• GLP compliance
COMPLIANCE TO
• PED Directive 2014/68/UE – Pressure equipment
• Machine Directive Macchine 2006/42/EC
• EMC Directive 2014/35/UE
• LVD Directive 2006/95/UE


Specifications for FVA3/A1 vertical lab sterilizer

Max. operating pressure (bar) 3.5
Overall dimensions (w x d x h in mm) 1200/600/1305
Chamber volume (liter) 158
Working volume (liter) 140
Loading height (mm) 875
Interior dimensions: (Ø x h) (mm) 500 x 700
Empty weight (kg) 175
Max. operating temperature (°C) 148