All products

%
Liebherr SRFvg 5511 laboratory refrigerator
Liebherr refrigerator for laboratories and research

Constant temperatures are essential when storing sensitive substances. This especially applies to work in laboratories, where even the slightest deviations can jeopardise the quality of research results. This is why Liebherr has developed new refrigerators and freezers specifically for this sector, combining maximum refrigeration performance with optimum temperature stability. Innovative safety features with monitoring and alarm functions offer all-round protection from all kinds of incident and malfunction. The next generation of appliances also set new standards in terms of energy efficiency and total cost of ownership. On the next few pages we present the latest results of research and development by the refrigeration specialists at Liebherr and show how they can benefit safety in your laboratory.

Product features

• Min./max. temperature log
The min./max. temperature log stores the minimum and maximum interior temperatures and shows on the display whether the storage temperatures were within the tolerance limits.

• +2 °C SafetyDevice
If the temperature falls below +2 °C due to a malfunction, the SafetyDevice takes control, stabilising the temperature, activating the alarm and protecting the contents from freezing

• Power failure alarm
When mains power return the device gives a visual and audible warning signal.

• LightAlarm
In the event of an uncontrolled temperature rise or other problems, the interior light of the appliance starts flashing. This visually shows when action is needed.

• Feedthrough for external sensors
An integrated opening allows a separate sensor to be connected for additional temperature monitoring without having to drill holes or break the door seal.
• Mechanical lock
Liebherr professional appliances are equipped with a mechanical lock and two keys. This ensures that unauthorised persons cannot access your valuable and sensitive stored goods.

• SmartMonitoring (optional)
The cloud-based digital solution continuously monitors and documents temperatures and alerts you immediately via email, text message or phone if any deviations occur.

• WiFi/LAN interface (optional)
The WiFi/LAN interface enables you to easily connect your appliances with Liebherr SmartMonitoring or existing local systems.

• Easy-to-clean interior
The inner liner made of fully recyclable, robust and odourless polystyrene is manufactured in one piece without joints. This makes it quick and easy to clean the large, rounded corners.

• Replaceable door seal
Save time and money: the insertable Liebherr door seals are easy to change. If a seal is damaged, you can replace it yourself without any tools. Contact Liebherr Customer Service to purchase replacements.

• Self-closing door < 90°
To make loading, unloading and cleaning easier, the appliance door stays open if opened by more than 90°. If the opening angle is less than 90°, it closes automatically for safety

• ±3 °C temperature stability
Temperature fluctuations must be minimal to ensure that the quality of sensitive substances is preserved. Liebherr Laboratory refrigerators have an impressive maximum deviation of just ±3 °C from the set temperature. This not only maintains the storage climate, but also the value of your stored goods.

• Standard compliance
The devices fully comply with the DIN 13277 standard and the IEC 61010-2-011 standard.
%
Kühner Stationary tray ISF1-Z(C)
The ISF1-Z and ISF1-X incubator shakers can be fitted with a shelf allowing cultivation in petri dishes. One or two shelves can be placed above the shaking table and fixed to the chamber walls with four screws.
%
Kühner Test tube holder RGH-28 (16 tubes)
• Test tube holder RGH-28 (16 tubes) (50ml falcon/TPP)
• For test tubes with 28 - 29 mm diameter
%
Kühner Tray for Microtiter plates F (spring)
• For 1x24 Microtiter plates or 1x24 Deepwell plates
• F Tray size : 800x420mm
• All plates are single clamped with springs
• Weight: 3.8kg
%
Kühner Clamp U-50
Clamp U-50 for Erlenmeyer flasks with 25 ml vol.
%
Kühner Tray with fixed clamps E-200
Tray with fixed clamps E-200 To load 20 Erlenmeyer flasks with a volume of 200 ml
%
Nabertherm charging plate N 61/H
We recommend these accessories for applications up to 1100 °C to protect the furnace floor, especially if a charging cart is used.
• Tmax 1100 °C
• Three raised edges
• Heat-resistant alloy 314 (AISI)/(DIN material no. 1.4841)
• Outer dimensions in mm (WxDxH 340x790x30)
%
Ohaus Rotor, Swing Out, 6x5ml RB
Frontier rotors extend the functionality of Frontier centrifuges by increasing the number of tubes of varied types and sizes that can be used in conjunction with each of the centrifuge models. Easy to clean and operate, the rotors are durably constructed to withstand demanding centrifugation.

Compatible adapters and other accessories:
• Buckets, For 30130880 x2 (30130895)
%
Vacuubrand Fluid aspiration system BVC professional G
Description
The BioChem-VacuuCenter BVC professional serves for aspiration and disposal of biological fluids, providing outstanding levels of comfort and safety for working with biological and biohazardous materials. A non-contact sensor monitors the liquid level in the collection bottle electronically and prevents overfilling. A disinfection routine allows the suction of disinfectants through aspiration hand set and tubing after switching off the pump, and so supports demanding safety protocols. The BVC professional with 4l PP bottle with self-closing quick couplings minimizes risk in transporting hazardous waste and of contamination in the workplace. The version with coated 2l borosilicate glass bottle allows you to work with aggressive disinfectants like chlorine bleach.
Performance features
• with all the advantages of the BVC control
• non-contact sensor for electronic monitoring of the liquid level in the collection bottle
• disinfection routine for the suction tubing for drawing in disinfectant after switching off the pump
• self-closing quick couplings (as accessory to the BVC professional G) for convenient and safe bottle change, e.g., for work with biohazards
• for professional work and a perfect fit for required safety protocols
%
Vacuubrand diaphragm pump ME 4R NT
This one-stage diaphragm pump works as a vacuum generator and as well as a compressor. All parts in contact with pumped media are made of aluminum and selected plastics (PTFE diaphragms and valves). They enable a wide range of applications for non-corrosive gases. The inlet and outlet connections of the ME 4R NT are equipped with regulator valves for vacuum and overpressure, respectively. Both the compression pressure and vacuum level can be adjusted. Inlet vacuum level and outlet pressure are indicated by manometers.
Performance features
• contamination-free pumping, evacuation and compression
• high flow rate even near ultimate vacuum
• adjustment of outlet pressure and vacuum level with regulator valves
• very low vibration
• exceptionally long diaphragm life and maintenance-free drive system for low lifetime costs
%
SPD-4A1 Esco Ascent Opti Ductless Fume Cabinet
Esco Ascent Opti Ductless Fume Cabinet is equipped with features previously found only on high-end ductless fume cabinets.
• Key Benefits:
• Certified to ASHRAE 110, BS 7989, BS 7258
• Easy to install
• Oval shaped arm ports provide good working flexibility and high containment levels
• State of the art airflow monitor and alarm system.
Features
• Grade 304 stainless steel work surface that will never rust, chip, or generate particles.
• A fully configurable Sentinel™ microprocessor control with audible and visual alarms for unsafe conditions.
• Built-in 5000k warm white fluorescent lighting.
• Removable work surface on a removable drain-pan for easy cleaning.
• Small Filter ID window to easily identify the type of filter being used.
• Optional transparent back, ideal for classroom demonstrations.
• Optional mobile cart for convenient relocation. Cart is equipped with shelves for storage purposes.
• Over 7 different Nanocarb™ carbon filter types, choose from: volatile organic compound, acid, mercury, sulphur, halogen, aldehyde or ammonia.
• Isocide™ antimicrobial coated structure eliminates 99.9% of bacterial presence on external surfaces within 24 hours.
• Extremely low energy consumption.
• Low noise levels (55 dBA).
• 2 provisions for electrical wiring at the back to easily connect any apparatus to a power supply from inside the main chamber.
%
DÜPERTHAL UTS pro M safety storage cabinet
The safety storage cabinets of the UTS line are specially constructed for the storage of hazardous substances close to where they are needed. With the UTS line, all containers are always safely stored and at your fingertips when you need them.

Health
• Ideal layout of ventilation ensures an optimised air exchange.

Safety
• In case of fire, a thermocouple automatically initiates the uninterrupted closing of the doors.

Working safety
• Equipotential bonding saddles as a standard on the cabinet help to prevent spark formation.


Specifications

• Pull-out tray extends automatically
• Automatic door closure in case of fire
• Efficient airflow for low energy consumption
• Interior fittings conductive and connected to the body
• Potential equalization tabs to prevent sparking
• Type 90 - 90-minute fire protection
• Smooth wing door technology


Technical details

• Base: 35 mm
• Storage areas: 1, Storage levels: 1
• Bottom tray: extendable
• Bottom tray insert: perforated sheet insert
• Type testing by TÜV SÜD according toDIN EN 14470-1, DIN EN 16121/16122
%
Heidolph Hei-VAP Core Low Boiling Dry Ice Package    
• Hei-VAP Core with motor lift and coated G5 dry ice condenser
• Vacuum pump Hei-VAC Valve Tec
• Manual vacuum controller
• Tubing set
%
Binder ED 720 drying and heating chambers with natural convection
The strengths of a BINDER ED series drying chamber include routine drying and sterilization tasks up to 300 °C. Thanks to the natural convection, all thermal processes which use this drying chamber are highly efficient. The ED series ensures fast, uniform drying.
Benefits
• Best energy efficiency on the market
• Excellent temporal and spatial temperature accuracy
• USB connection for recording data
• Temperature range up to +300 °C
Important characteristics
• Temperature range: +5 °C above ambient temperature to +300 °C
• Up to 30% lower energy consumption compared to conventional units on the market
• High temperature accuracy thanks to APT.line™ technology
• Natural convection
• Controller with LCD display
• Electromechanical control of the exhaust air flap
• 2 chrome-plated racks
• Units up to 115 liters are stackable
• Class 2 integrated independent adjustable temperature safety device (DIN 12880) with visual alarm
• Ergonomic handle design
• USB port for recording data
%
Binder BF 260 standard-incubators with forced convection
The BINDER incubator of the BF Avantgarde.Line series with forced convection is suitable for all gentle incubation applications, particularly under a full load and large batch throughputs. This incubator is extremely homogeneous and has quick recovery times.
Benefits
• Excellent temporal and spatial temperature accuracy
• High process reliability
• 100 °C disinfection routine
Important characteristics
• Temperature range (model 56 | 260): +7 °C above ambient temperature to +100 °C
• Temperature range (model 115): +8 °C above ambient temperature to +100 °C
• High temperature accuracy thanks to APT.line™ technology
• Forced convection
• Controller with LCD display
• Electromechanical control of the exhaust air flap
• Inner door made of tempered safety glass
• 2 chrome-plated racks
• Units up to 115 L are stackable
• 4 stable castors, two with brakes, from 720 liters
• Class 3.1 integrated independent temperature safety device (DIN 12880) with visual alarm
• Ergonomic handle design
• USB port for recording data
%
Binder KB PRO 260 Photostability Test Chamber with ICH light modul with light-dose control (LQC)
The Binder KB PRO 260 incubator is an ideal choice for photostability testing in accordance with ICH guideline Q1B. The unit can be easily equipped with the ICH LQC light module, which provides UV and visible (VIS) light to create a standardized test environment. The ICH LQC module also includes a VIS and a UVA sensor for precise light dose control. The lighting switches off automatically once the programmed light dose reaches the desired value, ensuring that the test is carried out under fully controlled conditions. The system is designed so that the photostability test can be completed within three days while minimizing thermal impact on the test material.

Scope of delivery

Binder KB PRO 260 Cooling incubator

• Temperature range: +5 °C bis +60 °C
• Proven APT.line ™ preheating chamber technology
• Energy-efficient cooling with modern inverter cooling unit
• Cooling with climate-neutral R-290 refrigerant
• Door heating to prevent condensation
• Adjustable fan speed
• Robust housing design with HIT sandwich technology
• Stainless-steel inner chamber
• Inner doors made of metal oxide-coated safety glass
• Two racks made of stainless steel
• Large access port with silicone plug
• Robust twin casters, with brakes at the front
• Intuitive touchscreen controller with time-segment and real-time programming
• Internal data logger, measured values can be read out in open format via USB
• Class 3.3 independent temperature safety device (DIN 12880) with visual and acoustic alarms
• Unit self-test for comprehensive status analysis
• Data interfaces: Ethernet, USB
• BINDER Multi Management Software APT-COM™ basic edition

BINDER ICH-LQC light module
The ICH-LQC light module contains two spherical light sensors in addition. The VIS sensor measures the illuminance of visible light and the UVA sensor measures the irradiance of UVA light. Both sensors evaluate the light with a spherical characteristic, which is useful for three-dimensional test objects. The light dose must be increased by a factor of 1.5 for photostability tests on flat test objects, such as printed products.

The ICH light module is also connected to the climate chamber via a data cable and the light control runs via the program controller. The light dose to be achieved for the two types of light is entered in the controller (typically 1.2 Mlx h visible light and 200 Wh/m² UVA) and the light cassettes are automatically switched off individually once the dose has been reached.

Scope of delivery of the BINDER ICH-LQC light module

• VIS light cassette with connection cable
• UVA light cassette with connection cable
• U-rails for mounting the light cassettes in the climate control cabinet
• Supply box with ballasts/power supply units
• Profile rails and bolts for attaching the supply box to the climate chamber
• Data cable
• Mains cable
• Operating instructions
• Spherical VIS light sensor for light dose control
• Spherical UVA light sensor for light dose control
%
Binder KB PRO 470 Photostability Test Chamber with ICH light modul
The Binder KB PRO 470 incubator is an ideal choice for photostability testing in accordance with ICH guideline Q1B. The unit can be easily equipped with an ICH light module, which provides UV and visible (VIS) light to create a standardized test environment. The system is designed to complete the photostability test within three days while minimizing thermal impact on the test material.

Scope of delivery

Binder KB PRO 470 Cooling incubator

• Temperature range: +5 °C bis +60 °C
• Proven APT.line ™ preheating chamber technology
• Energy-efficient cooling with modern inverter cooling unit
• Cooling with climate-neutral R-290 refrigerant
• Door heating to prevent condensation
• Adjustable fan speed
• Robust housing design with HIT sandwich technology
• Stainless-steel inner chamber
• Inner doors made of metal oxide-coated safety glass
• Two racks made of stainless steel
• Large access port with silicone plug
• Robust twin casters, with brakes at the front
• Intuitive touchscreen controller with time-segment and real-time programming
• Ergonomically adjustable control terminal
• Internal data logger, measured values can be read out in open format via USB
• Class 3.3 independent temperature safety device (DIN 12880) with visual and acoustic alarms
• Unit self-test for comprehensive status analysis
• Data interfaces: Ethernet, USB
• BINDER Multi Management Software APT-COM™ basic edition

ICH light module without light dose control
The ICH light module is connected to the climate chamber via a data cable. This makes it possible to control the irradiation duration of the light cassettes individually with a time segment program via the program controller of the climate chamber.
Scope of delivery of the BINDER ICH light modules
• VIS light cassette with connection cable
• UVA light cassette with connection cable
• U-rails for mounting the light cassettes in the climate control cabinet
• Supply box with ballasts/power supply units
• Profile rails and bolts for attaching the supply box to the climate chamber
• Data cable
• Mains cable
• Operating instructions
%
Miele PLW 8615 [EL CT] SST Large-chamber laboratory glasswasher
Laboratory washer – single door with combi tank, 900 mm wide, 351 l usable capacity
• Construction type: Freestanding, 1 glass vertical sliding door
• Front/back/side panels: Stainless Steel
• Electric door lock
• Buzzer, acoustic signal at end of programme
Control system
• Control type PST 20, full-touch colour display
• Programmable
• Selectable display languages
Standard electrical connection
• Total rated load in kW: 20,00
Water connection/drainage
• Cold water [number]: 2
• Hot water [number]: 1
• DI water [number]: 2
• Required flow pressure in kPa: 200-1000
Compressed air connection
• Compressed air connection, technical [number]: 1
Drying unit
• Air throughput in m³/h: 250
• HEPA filter class H13, HEPA filter filtration efficiency (DIN EN 1822) in %: 99,95
Features
• 2 integrated diaphragm dispenser pumps for liquid media
• 4 additional integrated dispenser pumps
• Variable-speed pump
• EasyLoad
• Spray arm monitoring
• Setting options for process chemicals (4 x 5 l or 2 x 5 l + 1 x 10 l)
• Wash cabinet made from high-quality stainless steel (1.4404/316L)
• Multi-coloured chamber lighting
Connection options
• Ethernet interface, External dispensing modules, USB interface, Central dispensing, Peak-load negotiation / energy management
%
SPD-4B1 Esco Ascent Opti Ductless Fume Cabinet
Esco Ascent Opti Ductless Fume Cabinet is equipped with features previously found only on high-end ductless fume cabinets.
• Key Benefits:
• Certified to ASHRAE 110, BS 7989, BS 7258
• Easy to install
• Oval shaped arm ports provide good working flexibility and high containment levels
• State of the art airflow monitor and alarm system.
Features
• Grade 304 stainless steel work surface that will never rust, chip, or generate particles.
• A fully configurable Sentinel™ microprocessor control with audible and visual alarms for unsafe conditions.
• Built-in 5000k warm white fluorescent lighting.
• Removable work surface on a removable drain-pan for easy cleaning.
• Small Filter ID window to easily identify the type of filter being used.
• Optional transparent back, ideal for classroom demonstrations.
• Optional mobile cart for convenient relocation. Cart is equipped with shelves for storage purposes.
• Over 7 different Nanocarb™ carbon filter types, choose from: volatile organic compound, acid, mercury, sulphur, halogen, aldehyde or ammonia.
• Isocide™ antimicrobial coated structure eliminates 99.9% of bacterial presence on external surfaces within 24 hours.
• Extremely low energy consumption.
• Low noise levels (55 dBA).
• 2 provisions for electrical wiring at the back to easily connect any apparatus to a power supply from inside the main chamber.
%
DÜPERTHAL UTS standard M safety storage cabinet
The safety storage cabinets of the UTS line are specially constructed for the storage of hazardous substances close to where they are needed. With the UTS line, all containers are always safely stored and at your fingertips when you need them.

Health
• Ideal layout of ventilation ensures an optimised air exchange.

Safety
• In case of fire, a thermocouple automatically initiates the uninterrupted closing of the doors.

Working safety
• Equipotential bonding saddles as a standard on the cabinet help to prevent spark formation.


Specifications

• Automatic door closure in case of fire
• Efficient airflow for low energy consumption
• Interior fittings conductive and connected to the body
• Optimal space utilization with fixed bottom containment trays
• Potential equalization tabs to prevent sparking
• Type 90 - 90-minute fire protection
• Smooth wing door technology


Technical details

• Base: 35 mm
• Storage areas: 1, Storage levels: 1
• Bottom tray: fixed
• Bottom tray insert: perforated sheet insert
• Type testing by TÜV SÜD according toDIN EN 14470-1, DIN EN 16121/16122