All products

%
Esco Drawer Rack
For standard 3-inch High Boxes for UUS-363/480/597/714 Model with 5 Inner Doors Configuration
• Rack Dimension (WxDxH): 139x551x245mm
• Can fit standard 130 x 130 x 80 mm (5.25” x 5.25” x 3”) boxes
• Has 3 shelves and contain 4 boxes per shelf. (3 x 4 configuration)
• Made of stainless steel and has handles.
• Weight: 4 Kg
%
Ohaus Rotor, Angle, 20x10ml RB, ID, Hi
Frontier rotors extend the functionality of Frontier centrifuges by increasing the number of tubes of varied types and sizes that can be used in conjunction with each of the centrifuge models. Easy to clean and operate, the rotors are durably constructed to withstand demanding centrifugation.

Compatible adapters and other accessories:
• No adapters
%
Miele APLW 018/1 upper basket
Upper basket equipped with 121 APLW 048 injector nozzles and 24 APLW 051 injector nozzles.
• Area of application: reprocessing laboratory glassware
• Only suitable for use on upper levels

Machine affiliation: Can be used for PLW 6111 devices.
%
Miele E 354 clamps for nozzle 6,0x220 mm
Height-adjustable for optimum positioning of laboratory glassware on the nozzle.
• Area of application: reprocessing laboratory glassware
• Height adjustable locking
• Suitable for bottles, Erlenmeyer flasks and round bottomed flasks for example
• Suitable for injector nozzle E 352

Machine affiliation: Can be used in PG 8504, PG 8583, PG 8583 CD, PG 8593 devices, for E 352 injector nozzles.
%
Nabertherm L 9/11/C550 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.

Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type N (1100 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With flap door (L)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation C550
• Solid state relays provide for lownoise operation

Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door

%
Kühner Tray with fixed clamps EX-250
Tray with fixed clamps EX-250 To load 21 x 250 ml Erlenmeyer flasks
%
Nabertherm collecting Pan, Ceramic for L..5/LE6
• Tmax 1300 °C
• Dimensions 190 x 170 x 20 mm
• For models LE 4, LE 6, L 5, LT 5, LV 5, LVT 5
%
Esco Voyager Software Kit with iRMAP (Intelligent Remote Monitoring Application Protocol)
Esco Voyager® is a PC-based software package developed for the remote monitoring, datalogging and programming / device configuration of Esco controlled environment laboratory equipment. Compatible equipment includes Laboratory Ovens and Incubators, Low Temperature Incubator, CO2 Incubators and Ultra-Low Temperature Freezer.
%
Ohaus Rotor, Angle, 12x15ml RB/FA, ID
Frontier rotors extend the functionality of Frontier centrifuges by increasing the number of tubes of varied types and sizes that can be used in conjunction with each of the centrifuge models. Easy to clean and operate, the rotors are durably constructed to withstand demanding centrifugation.

Compatible adapters and other accessories:
• Adapter, D11mm, 1.5/2.0ml Tubes x6 (30130886); Adapter, D13.5mm, 5ml Tubes x2 (30130890); Adapter, D13.5mm, 7ml Tubes x2 (30130889)
%
Miele APLW 019 upper basket
Upper basket with 121 unoccupied injector slots for nozzles with Ø 2.5 mm.
• Area of application: reprocessing laboratory glassware
• Only suitable for use on upper levels

Machine affiliation: Can be used for PLW 6111 devices.
%
Miele E 362 blind stopper
For the sealing of fittings to load carriers.
• Area of application: reprocessing laboratory glassware
• Thread M8 x 1
%
Nabertherm L 9/12/B510 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.

Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type S (1200 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With flap door (L)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation B510 (5 programs with each 4 segments)
• Solid state relays provide for lownoise operation

Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door

%
Kühner Tray with fixed clamps EX-300
Tray with fixed clamps EX-300 To load 21 x 300 ml Erlenmeyer flasks
%
Nabertherm collecting Pan, Ceramic for L..9
• Tmax 1300 °C
• Dimensions 240 x 220 x 20 mm
• For models L 9, LT 9, LV 9, LVT 9, N 7
%
Esco IQ/OQ Documentation for Esco ULT freezers
IQ/OQ protocol document is available for verifying that the equipment has been installed in accordance withinstallation specifications and is functioning and operating at the intended operational parameters.
%
Ohaus Rotor, Angle, 30x1.5/2.0ml, ID, Sealable
Frontier rotors extend the functionality of Frontier centrifuges by increasing the number of tubes of varied types and sizes that can be used in conjunction with each of the centrifuge models. Easy to clean and operate, the rotors are durably constructed to withstand demanding centrifugation.

Compatible adapters and other accessories:
• Adapter, D6mm, 0.2/0.4ml Tubes x6 (30130884); Adapter, D8mm, 0.5ml Tubes x6 (30130885)
%
Miele APLW 019/1 upper basket
Upper basket equipped with 121 APLW 047 injector nozzles.
• Area of application: reprocessing laboratory glassware
• Only suitable for use on upper levels

Machine affiliation: Can be used for PLW 6111 devices.
%
Miele A 2 cover net 1/2
For fixing delicate wash items.
• Area of application: reprocessing laboratory glassware
• Suitable for 1/2 inserts
• Plastic coated metal frame with plastic netting
• Size: 216 x 456 mm
%
Nabertherm L 9/12/C550 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.

Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type S (1200 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With flap door (L)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation C550
• Solid state relays provide for lownoise operation

Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door

%
Kühner Tray with fixed clamps EX-500
Tray with fixed clamps EX-500 To load 14 x 500 ml Erlenmeyer flasks