English
English
Magyar
Home
About us
Shop By Products
Shop By Brand
Contact us
blog
My Cart
Sign in
Public pricelist HUF
Prev
50
51
52
53
54
55
56
Next
Sort by
Relevance
Catalog price: High to Low
Catalog price: Low to High
Name - A to Z
Name - Z to A
Product Sequence Low to High
Product Sequence High to Low
All products
%
Vacuubrand VARIO® chemistry pumping unit PC 3001 VARIO select TE
The PC 3001 VARIO select pumping unit precisely controls the vacuum level in order to achieve unparalleled process control. This pump is suitable for even high boiling point solvents. The integrated VACUU•SELECT controller provides an easy-to-use, application based interface that covers all common lab applications. The VACUU•SELECT controller has you covered. Use manual set-point-control for simple processes, run fully automated distillations, or create your own application with simple drag-and-drop editing. For solvent evaporation, the VACUU•SELECT controller detects solvent boiling and automatically adjusts the pump's motor speed to maintain process control. The VARIO motor speed control also makes the pump whisper quiet and provides for exceptionally long maintenance intervals.
The inlet separator, made of glass with a robust protective coating, prevents particles and liquid droplets from entering the pump, preventing damage and extending pump life. The PC 3001 VARIO select TE is equiped with a dry ice condenser at the pump exhaust, so that no cooling water connection is required.
Performance features
• simplify lab work with the VACUU•SELECT vacuum controller with graphic user interface and predefined applications
• automatic boiling point detection and continuous optimization of vacuum levels for quick process times
• compact and powerful; superior performance even with continuous condensate purge
• whisper quiet and ultra low vibration
• eco-friendly: extremely low power consumption and efficient solvent recovery. Oil-free!
Compare
%
Nabertherm LT 40/12/B510 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.
Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type S (1200 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With lift door (LT)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation B510 (5 programs with each 4 segments)
• Solid state relays provide for lownoise operation
Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door
Compare
%
Kühner Tray with fixed clamps F-2000
Tray with fixed clamps F-2000 To load 9 Erlenmeyer flasks with a volume of 2000 ml
Compare
%
Vacuubrand VARIO® chemistry pumping unit PC 3001 VARIO select EK Peltronic
The PC 3001 VARIO select pumping unit precisely controls the vacuum level in order to achieve unparalleled process control. This pump is suitable for even high boiling point solvents. The integrated VACUU•SELECT controller provides an easy-to-use, application based interface that covers all common lab applications. The VACUU•SELECT controller has you covered. Use manual set-point-control for simple processes, run fully automated distillations, or create your own application with simple drag-and-drop editing. For solvent evaporation, the VACUU•SELECT controller detects solvent boiling and automatically adjusts the pump's motor speed to maintain process control. The VARIO motor speed control also makes the pump whisper quiet and provides for exceptionally long maintenance intervals.
The inlet separator, made of glass with a robust protective coating, prevents particles and liquid droplets from entering the pump, preventing damage and extending pump life. The included emission condenser Peltronic works without any cooling media like water or dry ice.
Performance features
• simplify lab work with the VACUU•SELECT vacuum controller with graphic user interface and predefined applications
• automatic boiling point detection and continuous optimization of vacuum levels for quick process times
• compact and powerful; superior performance even with continuous condensate purge
• whisper quiet and ultra low vibration
• eco-friendly: extremely low power consumption and efficient solvent recovery. Oil-free!
Compare
%
Nabertherm LT 40/12/C550 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.
Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type S (1200 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With lift door (LT)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation C550
• Solid state relays provide for lownoise operation
Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door
Compare
%
Kühner Tray with fixed clamps F-2500U
Tray with fixed clamps F-2500U to load 8 Ultra yield flasks with a volume of 2500 ml on a F-tray
Compare
%
Vacuubrand diaphragm pump MZ 2D NT
Diaphragm pumps are an excellent solution for continuous, oil-free evacuation and pumping of gases. All parts in these MZ 2 series pumps that are in contact with pumped media are made of aluminum, stainless steel and selected plastics, allowing a wide range of applications for non-corrosive gases. The two-stage construction provides the advantageous combination of high pumping speed and an ultimate vacuum down to 4 mbar. The highly flexible fabric-reinforced double diaphragms made of FKM provide high reliability and extended operating life. The NT-series features further improved performance data and compact design.
Performance features
• contamination-free pumping and evacuation
• high flow rate even near ultimate vacuum
• good ultimate vacuum
• whisper quiet and very low vibration
• exceptionally long diaphragm life and maintenance-free drive system for low lifetime costs
Compare
%
Nabertherm L 40/11/B510 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.
Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type N (1100 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With flap door (L)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation B510 (5 programs with each 4 segments)
• Solid state relays provide for lownoise operation
Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door
Compare
%
Kühner Tray with fixed clamps F-3000
Tray with fixed clamps F-3000 For 8 Erlenmeyer flasks with 3000 ml volume
Compare
%
Vacuubrand diaphragm pump MD 4 NT
Description
These three-stage diaphragm pumps are an excellent solution for continuous, oil-free pumping of non-corrosive gases. They reach an excellent ultimate vacuum of 1 mbar. All parts in contact with pumped gases and vapors are made of aluminum, stainless steel and carefully selected plastics suitable for a wide range of applications with non-corrosive gases. The new NT-series provides whisper quiet and ultra-low vibration operation, high leak tightness and improved performance. The highly flexible fabric-reinforced double diaphragm made of FKM is ideal for extended operating life.
Performance features
contamination-free pumping and evacuation
high flow rate even near ultimate vacuum
whisper quiet
very low vibration
exceptionally long diaphragm life and maintenance-free drive system for low lifetime cost
Compare
%
Nabertherm L 40/11/C550 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.
Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type N (1100 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With flap door (L)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation C550
• Solid state relays provide for lownoise operation
Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door
Compare
%
Vacuubrand MD 4 VARIO Select diaphragm pump
Designed for continuous, oil-free pumping of non-corrosive gases, this three-stage pump achieves vacuum levels as deep as 1 mbar. Crafted with aluminum, stainless steel, and carefully selected plastics, its durability ensures a wide range of applications. With whisper-quiet operation and ultra-low vibrations, the MD 4 VARIO select adapts its motor speed for precise vacuum control, while its fabric-reinforced double FKM diaphragm ensures extended life.
The VARIO design, featuring variable speed and the VACUU·SELECT vacuum controller, offers unmatched flexibility. Ideal for physics, analytics, and more, these pumps excel in contamination-free evacuation. Plus, with customized options available, meet your specific needs effortlessly. Enjoy extraordinary diaphragm life, minimum operational costs, and precise vacuum control with the VARIO® diaphragm pump.
Product features
• VACUU·SELECT vacuum controller with graphical user interface and predefined applications simplifies work in the laboratory
• Extraordinary diaphragm life for minimum operational and servicing costs
• Contamination-free pumping and evacuation
• Excellent ultimate vacuum and TURBO·MODE for use as backing pump for turbo pumps
Compare
%
Kühner Tray with fixed clamps F-4000
Tray with fixed clamps F-4000 For 5 Erlenmeyer flasks with 4000 ml volume
Compare
%
Nabertherm L 40/12/B510 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.
Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type S (1200 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With flap door (L)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation B510 (5 programs with each 4 segments)
• Solid state relays provide for lownoise operation
Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door
Compare
%
Kühner Tray with fixed clamps F-5000
Tray with fixed clamps F-5000 With 4 clamps
Compare
%
Vacuubrand chemistry diaphragm pump MD 4C NT
Three-stage chemistry-design diaphragm pumps are an excellent solution for continuous, oil-free pumping of corrosive gases and vapors and meet even challenging requirements. The three-stage design provides the advantageous combination of high pumping speed and very low ultimate vacuum. All parts of the MD 4C NT in contact with pumped media are made of chemically resistant fluoroplastics. Well-proven PTFE sandwich diaphragms provide increased reliability and extended operating life. Due to the gas ballast valve and its very good ultimate vacuum (even with gas ballast) the MD 4C NT is also suitable for pumping condensable vapors of high-boiling solvents. The NT-series features further improved performance data, easy service and superior vapor tolerance.
Performance features
• outstanding chemical resistance and superior vapor tolerance
• exceptionally high performance even at low vacuum
• excellent ultimate vacuum even with gas ballast
• whisper quiet and very low vibration
• long diaphragm life, maintenance-free drive system
Compare
%
Nabertherm L 40/12/C550 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.
Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type S (1200 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With flap door (L)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation C550
• Solid state relays provide for lownoise operation
Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door
Compare
%
Kühner Tray with fixed clamps F-6000
Tray with fixed clamps F-6000 To load 3 x 6000 ml Erlenmeyer flasks
Compare
%
Vacuubrand VARIO® chemistry diaphragm pump MD 4C VARIO select
The MD 4C VARIO select pump is an excellent solution for labs working with most high boiling point solvents. The pump's three stage configuration gives it an ultimate vacuum rating of 1.5 mbar.
The integrated VACUU•SELECT controller provides an easy-to-use, application based interface that covers all common lab applications. The VACUU•SELECT controller has you covered. Use manual set-point-control for simple processes, run fully automated distillations, or create your own application with simple drag-and-drop editing. For solvent evaporation, the VACUU•SELECT controller continuously detects the boiling point and automatically adjusts the vacuum process as necessary. VARIO's on-demand motor speed control results in whisper-quiet operation and unparalleled length of service intervals for wear parts.
Performance features
• VACUU•SELECT vacuum controller with graphical user interface and predefined applications simplifies work in the laboratory
• automatic boiling point detection and adjustment of the vacuum for short process times
• extraordinary diaphragm life for minimum operational and servicing costs
• meets high vacuum requirements for most high boiling solvents
Compare
%
Nabertherm LT 60/11/B510 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.
Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type N (1100 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With lift door (LT)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation B510 (5 programs with each 4 segments)
• Solid state relays provide for lownoise operation
Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door
Compare
Prev
50
51
52
53
54
55
56
Next