English
English
Magyar
Home
About us
Shop By Products
Shop By Brand
Contact us
blog
My Cart
Sign in
Public pricelist HUF
Prev
61
62
63
64
65
66
67
Next
Sort by
Relevance
Catalog price: High to Low
Catalog price: Low to High
Name - A to Z
Name - Z to A
Product Sequence Low to High
Product Sequence High to Low
All products
%
Heidolph Silicone Tubing, id: 4.8mm - wt: 2.5mm
For Single- and Multi-Channel use (not suitable with cassette small)
• Application: Platinum-coated silicone hose for use in pharmaceuticals and biology
Features:
• Extremely smooth interior prevents bacterial growth
• Biocompatible, minimal adsorption and absorption
• Best flow properties, high temperature stability
• Absolutely inert, softener-free
• Material: Polydimethylsiloxane with siliceous earth and silicone additives; translucent white; excellent resistance to initial pressure
• Complies with the standards: USP Class VI, FDA, meets GLP and NSF
• Temperature range: -80 to +200 °C
• Sterilization: Can be autoclaved for 30 min at 1 bar or sterilized by irradiation
• Restriction: Not suitable for concentrated solvents, oils, acids or dilute caustic soda; relatively high permeability to gas
Compare
%
Heidolph Silicone Tubing, id: 1.7mm - wt: 1.6mm
For Single- and Multi-Channel use (not suitable with cassette small)
• Application: Platinum-coated silicone hose for use in pharmaceuticals and biology
Features:
• Extremely smooth interior prevents bacterial growth
• Biocompatible, minimal adsorption and absorption
• Best flow properties, high temperature stability
• Absolutely inert, softener-free
• Material: Polydimethylsiloxane with siliceous earth and silicone additives; translucent white; excellent resistance to initial pressure
• Complies with the standards: USP Class VI, FDA, meets GLP and NSF
• Temperature range: -80 to +200 °C
• Sterilization: Can be autoclaved for 30 min at 1 bar or sterilized by irradiation
• Restriction: Not suitable for concentrated solvents, oils, acids or dilute caustic soda; relatively high permeability to gas
Compare
%
Heidolph Silicone Tubing, id: 0.8mm - wt: 1.6mm
For Single- and Multi-Channel use (not suitable with cassette small)
• Application: Platinum-coated silicone hose for use in pharmaceuticals and biology
Features:
• Extremely smooth interior prevents bacterial growth
• Biocompatible, minimal adsorption and absorption
• Best flow properties, high temperature stability
• Absolutely inert, softener-free
• Material: Polydimethylsiloxane with siliceous earth and silicone additives; translucent white; excellent resistance to initial pressure
• Complies with the standards: USP Class VI meets GLP and NSF
• Temperature range: -80 to +200 °C
• Sterilization: Can be autoclaved for 30 min at 1 bar or sterilized by irradiation
• Restriction: Not suitable for concentrated solvents, oils, acids or dilute caustic soda; relatively high permeability to gas
Compare
%
Heidolph Silicone Tubing, id: 7.9mm - wt: 2.5mm
For Single- and Multi-Channel use (not suitable with cassette small)
• Application: Platinum-coated silicone hose for use in pharmaceuticals and biology
Features:
• Extremely smooth interior prevents bacterial growth
• Biocompatible, minimal adsorption and absorption
• Best flow properties, high temperature stability
• Absolutely inert, softener-free
• Material: Polydimethylsiloxane with siliceous earth and silicone additives; translucent white; excellent resistance to initial pressure
• Complies with the standards: USP Class VI, FDA, meets GLP and NSF
• Temperature range: -80 to +200 °C
• Sterilization: Can be autoclaved for 30 min at 1 bar or sterilized by irradiation
• Restriction: Not suitable for concentrated solvents, oils, acids or dilute caustic soda; relatively high permeability to gas
Compare
%
Heidolph Silicone Tubing, id: 6.4mm - wt: 1.6mm
For Single- and Multi-Channel use (not suitable with cassette small)
• Application: Platinum-coated silicone hose for use in pharmaceuticals and biology
Features:
• Extremely smooth interior prevents bacterial growth
• Biocompatible, minimal adsorption and absorption
• Best flow properties, high temperature stability
• Absolutely inert, softener-free
• Material: Polydimethylsiloxane with siliceous earth and silicone additives; translucent white; excellent resistance to initial pressure
• Complies with the standards: USP Class VI, FDA, meets GLP and NSF
• Temperature range: -80 to +200 °C
• Sterilization: Can be autoclaved for 30 min at 1 bar or sterilized by irradiation
• Restriction: Not suitable for concentrated solvents, oils, acids or dilute caustic soda; relatively high permeability to gas
Compare
%
Heidolph Silicone Tubing, id: 4.8mm - wt: 1.6mm
For Single- and Multi-Channel use (not suitable with cassette small)
• Application: Platinum-coated silicone hose for use in pharmaceuticals and biology
Features:
• Extremely smooth interior prevents bacterial growth
• Biocompatible, minimal adsorption and absorption
• Best flow properties, high temperature stability
• Absolutely inert, softener-free
• Material: Polydimethylsiloxane with siliceous earth and silicone additives; translucent white; excellent resistance to initial pressure
• omplies with the standards: USP Class VI, FDA, meets GLP and NSF
• Temperature range: -80 to +200 °C
• Sterilization: Can be autoclaved for 30 min at 1 bar or sterilized by irradiation
• Restriction: Not suitable for concentrated solvents, oils, acids or dilute caustic soda; relatively high permeability to gas
Compare
%
Heidolph Silicone Extension Tubing, id: 0.9mm - wt: 0.9mm
Extension tube for Cassette small
• Application: Platinum-coated silicone hose for use in pharmaceuticals and biology
Features:
• Extremely smooth interior prevents bacterial growth
• Biocompatible, minimal adsorption and absorption
• Best flow properties, high temperature stability
• Absolutely inert, softener-free
• Material: Polydimethylsiloxane with siliceous earth and silicone additives; translucent white; excellent resistance to initial pressure
• Complies with the standards: USP Class VI meets GLP and NSF
• Temperature range: -80 to +200 °C
• Sterilization: Can be autoclaved for 30 min at 1 bar or sterilized by irradiation
• Restriction: Not suitable for concentrated solvents, oils, acids or dilute caust
Compare
%
Heidolph Silicone Two-Stop Tubing, id: 2.8mm - wt: 0.9mm
Two-stop tubing (40 cm) for Cassette small
• Application: Platinum-coated silicone hose for use in pharmaceuticals and biology
Features:
• Extremely smooth interior prevents bacterial growth
• Biocompatible, minimal adsorption and absorption
• Best flow properties, high temperature stability
• Absolutely inert, softener-free
• Material: Polydimethylsiloxane with siliceous earth and silicone additives; translucent white; excellent resistance to initial pressure
• Complies with the standards: USP Class VI meets GLP and NSF
• Temperature range: -80 to +200 °C
• Sterilization: Can be autoclaved for 30 min at 1 bar or sterilized by irradiation
• Restriction: Not suitable for concentrated solvents, oils, acids or dilute caustic soda; relatively high permeability to gas
Compare
%
Heidolph Silicone Two-Stop Tubing, id: 0.9mm - wt: 0.9mm
Two-stop tubing (40 cm) for Cassette small
• Application: Platinum-coated silicone hose for use in pharmaceuticals and biology
Features:
• Extremely smooth interior prevents bacterial growth
• Biocompatible, minimal adsorption and absorption
• Best flow properties, high temperature stability
• Absolutely inert, softener-free
• Material: Polydimethylsiloxane with siliceous earth and silicone additives; translucent white; excellent resistance to initial pressure
• Complies with the standards: USP Class VI meets GLP and NSF
• Temperature range: -80 to +200 °C
• Sterilization: Can be autoclaved for 30 min at 1 bar or sterilized by irradiation
• Restriction: Not suitable for concentrated solvents, oils, acids or dilute caustic soda; relatively high permeability to gas
Compare
%
Heidolph Foot Switch for Hei-FLOW
For start and stop. Only for:
Hei-FLOW Expert 120
Hei-FLOW Expert 600
Hei-FLOW Ultimate 120
Hei-FLOW Ultimate 600
Compare
%
Heidolph Adaptor for multichannel pump heads
To connect pump drive to multi-channel pump head
Compare
%
Heidolph Multi-Channel Cassette small
• Flow rates from 0.005 to 37 ml/min
• Suitable for tubes with 0.9-mm wall thickness (wt)
• Tube diameters available: 0.2 / 0.5 / 0.9 / 1.4 and 2.8 mm
• Two-Stop Tubing (40 cm) required to operate cassette small
Combinations:
• C 4 multi-channel pump head: Max. 4 cassettes small
• C 12 multi-channel pump head: Max. 12 cassettes small
Compare
%
Heidolph Multi-Channel Cassette medium
• Flow rates from 0.24 to 27 ml/min
• Suitable for tubes with 1.6-mm wall thickness (wt)
• Tube diameters available: 0.8 and 1.7 mm
Combinations:
• C 8 multi-channel pump head: Max. 8 cassettes medium
Compare
%
Heidolph Multi-Channel Cassette large
• Flow rates from 1 to 364 ml/min
• Suitable for tubes with 1.6-mm wall thickness (wt)
• Tube diameters available: 1.7 / 3.1 / 4.8 and 6.4 mm
Combinations:
• C 8 multi-channel pump head: Max. 4 cassettes large
Compare
%
Heidolph Multi-channel Pump Head C 12
• Accepts 12 cassettes small
• 8 rollers minimizing pulsation
Compare
%
Heidolph Multi-channel Pump Head C 4
• Accepts 4 cassettes small
• 8 rollers for low pulsation
Compare
%
Heidolph Multi-channel Pump Head C 8
• Accepts 8 cassettes medium or 4 cassettes large
• 4-roller design
Compare
%
Heidolph Single-Channel Pump Heads SP quick (wall thickness 2.5 mm)
• Fast and convenient tube changes
• Low pulsation due to 5 roller system
• Pump head features ball bearings
• Rollers made of stainless steel
• For tubes with a 2.5-mm wall thickness (wt)
• Depending on drive and tubing, flow rate ranges from 0.38 to 3,436 ml per minute
Compare
%
Heidolph Single-Channel Pump Heads SP quick (wall thickness 1.6 mm)
• Fast and convenient tube changes
• Low pulsation due to 5 roller system
• Pump head features ball bearings
• Rollers made of stainless steel
• For tubes with a 1.6-mm wall thickness (wt)
• Depending on drive and tubing, flow rate ranges from 0.38 to 3,436 ml per minute
Compare
%
Heidolph Single-Channel Pump Heads SP vario
• Suitable for most Heidolph tubing due to adjustable roller spacing
• Convex rollers do not squeeze or crush organic cell cultures
• Pump head features ball bearings
• Rollers made of stainless steel and aluminum
• Depending on drive and tubing, the flow rate ranges from 2.0 to 4,151 ml per minute
Compare
Prev
61
62
63
64
65
66
67
Next