All products

%
Nabertherm lid for Rectangular Saggar
• Made of ceramic
• Dimensions 110 x 75 x 5 mm
• For rectangular saggar (699000279)
%
Ohaus Rotor Swing out 4x750ml ID Sealable
Frontier rotors extend the functionality of Frontier centrifuges by increasing the number of tubes of varied types and sizes that can be used in conjunction with each of the centrifuge models. Easy to clean and operate, the rotors are durably constructed to withstand demanding centrifugation.

Compatible adapters and other accessories:
• Bucket 1x750ml D99mm FB x2 V1 (30602502)*All racks are used with bucket 30602502 only; Lid Assembly for Bucket 30602502 PC 2x (30553122); O-Ring for bucket 30602502 NBR 10x (30553123); Rack 1x500ml D96mm FA x2 (30553124); Rack 1x250ml D62mm FB x2 V1 (30553125); Rack 1x175/225ml D61mm FA x2 (30553126); Rack 3x100ml D41mm RB x2 (30553127); Rack 5x50ml D29mm FA x2 (30553128); Rack 5x50ml D29mm FAw/R x2 (30553129); Rack 5x50ml D29mm FAw/R x2 (30553130); Rack 7x50ml D29mm RB x2 (30553131); Rack 8x30ml D26mm RB x2 (30553132); Rack 14x15ml D17mm FA x2 (30553133); Rack 17x15ml D17mm FA x2 (30553134); Rack 18x15ml D17mm RB x2 (30553135); Rack 21x10ml D16mm RB x2 (30553136); Rack 32x7ml D13mm RB x2 (30553138); Rack 27x1.8/7ml D13mm Vac/Sar x2 (30553139); Rack 18x4/10ml D16mm Vac/Sar x2 (30553140); Rack 38x1.1/1.4ml D8mm Sar x2 (30559377); Bucket MTP x2 V1 (30553104); Holder removing aid for Bucket (30553105); Lid Assembly for bucket 30553104 PC x2 (30553117); O-Ring for bucket 30553104 SIL x2 (30553118); Bucket MTP x2 V2 (30553119)
%
Vacuubrand diaphragm pump MD 1
The MD 1 diaphragm pump is an excellent choice for oil-free evacuation and pumping of non-corrosive gases down to 1.5 mbar ultimate vacuum. The three-stage design with precisely guided flat diaphragms provides outstanding pumping speed even close to the ultimate vacuum, especially when compared with similarly rated two-stage diaphragm pumps. The MD 1 is an ultra-low vibration pump with very long diaphragm lilfetime and stable ultimate vacuum documented with years of testing. With a flow path consisting of aluminum and selected plastics (diaphragms and valves made of PTFE/FKM and FKM, respectively) the pumps are suitable for a wide range of applications with non-corrosive gases.

Performance features
• contamination-free pumping and evacuation
• high flow rate even near ultimate vacuum
• excellent ultimate vacuum
• whisper quiet and ultra-low vibration
• proven long diaphragm life, maintenance-free drive system
%
Heidolph Heat-On Multi-Well Holder
Replace oil baths and jacket heaters in your lab and reduce the risk of fire. Heat-On blocks are by far the safest, fastest and most efficient method for heating and mixing solutions in round bottom flasks from 10 ml to 5 l.
• Highest Level of Safety
Increased occupational safety and fire protection: The elimination of oil baths prevents accidents, fires and contamination. The unique design prevents glass breakage and thus minimizes the risk of possible cutting injuries and leaking liquids. The high temperature accuracy offers maximum safety for applications up to 260 °C.
• Superior Ease of Use
The temperature can be measured conveniently and precisely in the medium or directly at the reaction attachment. No oil is required as a heat conductor, as the attachments snugly enclose the flasks. The cleaning effort is minimized. The PTFE coating offers the highest resistance to chemicals and correspondingly many years of use.
• Lasting Reduction of Cost of Ownership
The simplified handling minimizes process times and increases sample throughput: 150 ml of water are brought to the boil in less than 11 minutes. In addition, the 66 % faster heating times compared to conventional oil baths save on energy costs.
%
Ohaus AX8201 precision balance
Striking the ideal balance between inventive features and functional, uncomplicated weighing capabilities, the OHAUS Adventurer incorporates all of the applications necessary for routine weighing and measurement activities. With a color touchscreen, GLP/GMP compliance capabilities, two USB ports, and much more, Adventurer is the most complete balance in its class.
• Display
4.3" (109 mm) Full-color VGA graphic touchscreen with user-controlled brightness
• Operation
AC adapter (included)
• Communication
RS232, USB Host, USB Device (included). GLP/GMP data output with real-time clock.
• Construction
Metal base, ABS top housing, stainless steel pan, glass draftshield with 2-piece top mounted side doors & sliding top door (1mg models only), illuminated up-front level indicator, weigh below hook, security bracket, calibration lock, full housing in-use cover
• Design Features
Selectable environmental filters, auto tare, user selectable span calibration points, software lockout and reset menu, user selectable communication settings and data print options, user definable project and user IDs, up to 9 operating languages
%
Heidolph Heat-On Multi-Well 10-ml insert
This Heat-On insert is suitable for heating 10 ml round bottom flasks.
For optimal use it is recommended that you buy the Multi-Well holder together with safety lifting handles.
The maximum temperature for continuous use is 260 °C. In order to measure this precisely with a temperature sensor, a small hole is provided on one side of the Heat-On Block.
%
Ohaus AX8201/E precision balance
Striking the ideal balance between inventive features and functional, uncomplicated weighing capabilities, the OHAUS Adventurer incorporates all of the applications necessary for routine weighing and measurement activities. With a color touchscreen, GLP/GMP compliance capabilities, two USB ports, and much more, Adventurer is the most complete balance in its class.
• Display
4.3" (109 mm) Full-color VGA graphic touchscreen with user-controlled brightness
• Operation
AC adapter (included)
• Communication
RS232, USB Host, USB Device (included). GLP/GMP data output with real-time clock.
• Construction
Metal base, ABS top housing, stainless steel pan, glass draftshield with 2-piece top mounted side doors & sliding top door (1mg models only), illuminated up-front level indicator, weigh below hook, security bracket, calibration lock, full housing in-use cover
• Design Features
Selectable environmental filters, auto tare, user selectable span calibration points, software lockout and reset menu, user selectable communication settings and data print options, user definable project and user IDs, up to 9 operating languages
%
Heidolph Heat-On Multi-Well 25-ml insert
This Heat-On insert is suitable for heating 25 ml round bottom flasks.
For optimal use it is recommended that you buy the Multi-Well holder together with safety lifting handles.
The maximum temperature for continuous use is 260 °C. In order to measure this precisely with a temperature sensor, a small hole is provided on one side of the Heat-On Block.
%
Heidolph Viton® Tubing, id: 6.4mm - wt: 1.6mm
For Single- and Multi-Channel use (not suitable with cassette small)
• Application: Excellent acid resistance at high temperatures
Features:
• Low gas permeability
• Resistant to solvents and corrosives at high temperatures
• Material: Fluorocarbon rubber, thermoformed Viton® B (67% fluorinated); opaque black
• Complies with the standards: GLP conform
• Temperature range: -30 to +205 °C
• Sterilization: Sterilization is not recommended
• Restriction: Limited performance life
%
Ohaus AX8201M precision balance
Striking the ideal balance between inventive features and functional, uncomplicated weighing capabilities, the OHAUS Adventurer incorporates all of the applications necessary for routine weighing and measurement activities. With a color touchscreen, GLP/GMP compliance capabilities, two USB ports, and much more, Adventurer is the most complete balance in its class.
• Display
4.3" (109 mm) Full-color VGA graphic touchscreen with user-controlled brightness
• Operation
AC adapter (included)
• Communication
RS232, USB Host, USB Device (included). GLP/GMP data output with real-time clock.
• Construction
Metal base, ABS top housing, stainless steel pan, glass draftshield with 2-piece top mounted side doors & sliding top door (1mg models only), illuminated up-front level indicator, weigh below hook, security bracket, calibration lock, full housing in-use cover
• Design Features
Selectable environmental filters, auto tare, user selectable span calibration points, software lockout and reset menu, user selectable communication settings and data print options, user definable project and user IDs, up to 9 operating languages
%
Heidolph Heat-On Multi-Well 50-ml insert
This Heat-On insert is suitable for heating 50 ml round bottom flasks.
For optimal use it is recommended that you buy the Multi-Well holder together with safety lifting handles.
The maximum temperature for continuous use is 260 °C. In order to measure this precisely with a temperature sensor, a small hole is provided on one side of the Heat-On Block.
%
Ohaus EXP8201M Precision Balance
Engineered for Accuracy, Designed for Demanding Applications

The new Explorer EXP series offers a premium weighing performance, compliance support and data traceability. The advanced features take the EXP to the next level by optimizing the user experience. This Flagship balance is crafted to meet the most demanding requirements of modern scientific research.

Product features

• Applications: Basic Weighing, Parts Counting, Check Counting, Percent Weighing, Check Weighing, Dynamic Weighing, Totalization, Formulation, Differential, Density Determination, Peak Hold, Pipette Adjustment, SQC, Fill Weight Variation, Flow Rate Control
• 7-inch TFT 16.7M Color Touch Screen with Glass Overlay
• AC Adapter Input: 100-240 VAC 0.5A 50-60 Hz
• USB Host (Type A) x 2, USB Device (Type B) x 1, USB Device (Type C) x 1, Ethernet (RJ45) x 1, RS232 x 1; Optional Wi-Fi, Bluetooth Dongle
• Legal for Trade: EC Type Approved
• Modular Design
• Metal Base and Housing
• SST 316 weighing pan
• Motorized Leveling
• 2 touchless sensors and Status lights.
• Time Synchronization NTP
• Support for HID (Human Interface Device) connection to a computer without the need for drivers
• 4 level user management and an internal system log capacity of 100,000 entries
• 3000 application sample libraries
• Weighing pan size: 178 mm×201 mm (Trapezoid Pan)
• Assembled Dimensions (W×D×H): 229 mm×408 mm×97 mm
%
Heidolph Heat-On Multi-Well 100-ml insert
This Heat-On insert is suitable for heating 100 ml round bottom flasks.
For optimal use it is recommended that you buy the Multi-Well holder together with safety lifting handles.
The maximum temperature for continuous use is 260 °C. In order to measure this precisely with a temperature sensor, a small hole is provided on one side of the Heat-On Block.
%
Ohaus EXP8201 Precision Balance
Engineered for Accuracy, Designed for Demanding Applications

The new Explorer EXP series offers a premium weighing performance, compliance support and data traceability. The advanced features take the EXP to the next level by optimizing the user experience. This Flagship balance is crafted to meet the most demanding requirements of modern scientific research.

Product features

• Applications: Basic Weighing, Parts Counting, Check Counting, Percent Weighing, Check Weighing, Dynamic Weighing, Totalization, Formulation, Differential, Density Determination, Peak Hold, Pipette Adjustment, SQC, Fill Weight Variation, Flow Rate Control
• 7-inch TFT 16.7M Color Touch Screen with Glass Overlay
• AC Adapter Input: 100-240 VAC 0.5A 50-60 Hz
• USB Host (Type A) x 2, USB Device (Type B) x 1, USB Device (Type C) x 1, Ethernet (RJ45) x 1, RS232 x 1; Optional Wi-Fi, Bluetooth Dongle
• Modular Design
• Metal Base and Housing
• SST 316 weighing pan
• Motorized Leveling
• 2 touchless sensors and Status lights.
• Time Synchronization NTP
• Support for HID (Human Interface Device) connection to a computer without the need for drivers
• 4 level user management and an internal system log capacity of 100,000 entries
• 3000 application sample libraries
• Weighing pan size: 178 mm×201 mm (Trapezoid Pan)
• Assembled Dimensions (W×D×H): 229 mm×408 mm×97 mm
%
Nabertherm L 15/12/C550 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.

Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type S (1200 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With flap door (L)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation C550
• Solid state relays provide for lownoise operation

Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door

%
Kühner Tray with fixed clamps F-25
Tray with fixed clamps F-25 To load 153 Erlenmeyer flasks with a volume of 25 ml
%
Heidolph Viton® Tubing, id: 7.9mm - wt: 2.5mm
For Single- and Multi-Channel use (not suitable with cassette small)
• Application: Excellent acid resistance at high temperatures
Features:
• Low gas permeability
• Resistant to solvents and corrosives at high temperatures
• Material: Fluorocarbon rubber, thermoformed Viton® B (67% fluorinated); opaque black
• Complies with the standards: GLP conform
• Temperature range: -30 to +205 °C
• Sterilization: Sterilization is not recommended
• Restriction: Limited performance life
%
Ohaus Rotor Angle 4x500ml ID
Frontier rotors extend the functionality of Frontier centrifuges by increasing the number of tubes of varied types and sizes that can be used in conjunction with each of the centrifuge models. Easy to clean and operate, the rotors are durably constructed to withstand demanding centrifugation.

Compatible adapters and other accessories:
• Adapter 1x250ml D60.5mm FA x2 (30559416)); Adapter 1x175/225 ml D61.5mm FA x2 (30559417); Adapter 1x50ml D29.5mm FA x2 (30559419); Adapter 3x50ml D29mm RB x2 (30559420); Adapter 4x30ml D25.5mm RB x2 (30559421); Adapter 6x15ml D17mm FA x2 (30559422); Adapter 1x250ml D61.5mm FB x2 (30564850)
%
Vacuubrand chemistry diaphragm pump MD 1C
Three-stage chemistry-design diaphragm pumps are an excellent solution for continuous, oil-free pumping of corrosive gases and vapors and meet high requirements regarding ultimate vacuum. The three-stage construction provides the advantageous combination of high pumping speed and deep ultimate vacuum in a pump with a very small footprint. All parts in contact with pumped media are made of chemically resistant fluoroplastics. Well-proven PTFE sandwich diaphragms increase reliability and extend operating life. The MD 1C with gas ballast valve is optimally prepared for pumping easily condensable vapors (high boiling solvents).

Performance features
• outstanding chemical resistance and superior vapor tolerance
• exceptionally high performance even at low vacuum
• excellent ultimate vacuum even with gas ballast
• whisper quiet and ultra low vibration
• proven long diaphragm life, maintenance-free drive system
%
Heidolph Heat-On Multi-Well 150-ml insert
This Heat-On insert is suitable for heating 150 ml round bottom flasks.
For optimal use it is recommended that you buy the Multi-Well holder together with safety lifting handles.
The maximum temperature for continuous use is 260 °C. In order to measure this precisely with a temperature sensor, a small hole is provided on one side of the Heat-On Block.