Nabertherm L & LT professional muffle furnaces

%
Nabertherm L 1/12/R7 muffle furnace
The muffle furnaces L have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.

Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type S (1200 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With flap door (L)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Solid state relays provide for lownoise operation
• R7 (1 program with 1 segment)

Option
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door
%
Nabertherm LT 3/11/B510 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.

Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type N (1100 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With lift door (LT)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation B510 (5 programs with each 4 segments)
• Solid state relays provide for lownoise operation

Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door

%
Nabertherm LT 3/11/C550 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.

Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type N (1100 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With lift door (LT)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation C550
• Solid state relays provide for lownoise operation

Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door

%
Nabertherm LT 3/12/B510 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.

Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type S (1200 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With lift door (LT)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation B510 (5 programs with each 4 segments)
• Solid state relays provide for lownoise operation

Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door

%
Nabertherm LT 3/12/C550 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.

Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type S (1200 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With lift door (LT)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation C550
• Solid state relays provide for lownoise operation

Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door

%
Nabertherm L 3/11/B510 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.

Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type N (1100 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With flap door (L)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation B510 (5 programs with each 4 segments)
• Solid state relays provide for lownoise operation

Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door

%
Nabertherm L 3/11/C550 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.

Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type N (1100 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With flap door (L)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation C550
• Solid state relays provide for lownoise operation

Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door

%
Nabertherm muffle furnace L 3/12/C550
The muffle furnaces L 1/12 - LT 40/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability. The muffle furnaces come equipped with either a flap door or lift door at no extra charge.
Standard Equipment
• Tmax 1100 °C or 1200 °C
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 40/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type N (1100 °C) or type S (1200 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• Optional flap door (L) which can be used as work platform or lift door (LT) with hot surface facing away from the operator
• Dual shell housing made of textured stainless steel sheets with additional fan cooling for low surface temperature
• Exclusive use of insulation materials without categorization according to EC Regulation No. 1272/2008 (CLP)
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller B510 resp. R7 for L 1/12 (5 programs with each 4 segments)
• Solid state relays provide for lownoise operation
• Defined application within the constraints of the operating instructions
• NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive
%
Nabertherm L 3/12/B510 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.

Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type S (1200 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With flap door (L)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation B510 (5 programs with each 4 segments)
• Solid state relays provide for lownoise operation

Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door

%
Nabertherm muffle furnace LT 5/11/B510
The muffle furnaces L 1/12 - LT 40/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability. The muffle furnaces come equipped with either a flap door or lift door at no extra charge.
Standard Equipment
• Tmax 1100 °C or 1200 °C
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 40/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type N (1100 °C) or type S (1200 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• Optional flap door (L) which can be used as work platform or lift door (LT) with hot surface facing away from the operator
• Dual shell housing made of textured stainless steel sheets with additional fan cooling for low surface temperature
• Exclusive use of insulation materials without categorization according to EC Regulation No. 1272/2008 (CLP)
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller B510 resp. R7 for L 1/12 (5 programs with each 4 segments)
• Solid state relays provide for lownoise operation
• Defined application within the constraints of the operating instructions
• NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive
%
Nabertherm muffle furnace L 5/11/B510
The muffle furnaces L 1/12 - LT 40/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability. The muffle furnaces come equipped with either a flap door or lift door at no extra charge.
Standard Equipment
• Tmax 1100 °C or 1200 °C
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 40/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type N (1100 °C) or type S (1200 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• Optional flap door (L) which can be used as work platform or lift door (LT) with hot surface facing away from the operator
• Dual shell housing made of textured stainless steel sheets with additional fan cooling for low surface temperature
• Exclusive use of insulation materials without categorization according to EC Regulation No. 1272/2008 (CLP)
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller B510 resp. R7 for L 1/12 (5 programs with each 4 segments)
• Solid state relays provide for lownoise operation
• Defined application within the constraints of the operating instructions
• NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive
%
Nabertherm muffle furnace L 5/11/C550
The muffle furnaces L 1/12 - LT 40/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability. The muffle furnaces come equipped with either a flap door or lift door at no extra charge.
Standard Equipment
• Tmax 1100 °C or 1200 °C
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 40/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type N (1100 °C) or type S (1200 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• Optional flap door (L) which can be used as work platform or lift door (LT) with hot surface facing away from the operator
• Dual shell housing made of textured stainless steel sheets with additional fan cooling for low surface temperature
• Exclusive use of insulation materials without categorization according to EC Regulation No. 1272/2008 (CLP)
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller B510 resp. R7 for L 1/12 (5 programs with each 4 segments)
• Solid state relays provide for lownoise operation
• Defined application within the constraints of the operating instructions
• NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive
%
Nabertherm muffle furnace LT 5/12/B510
The muffle furnaces L 1/12 - LT 40/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability. The muffle furnaces come equipped with either a flap door or lift door at no extra charge.
Standard Equipment
• Tmax 1100 °C or 1200 °C
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 40/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type N (1100 °C) or type S (1200 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• Optional flap door (L) which can be used as work platform or lift door (LT) with hot surface facing away from the operator
• Dual shell housing made of textured stainless steel sheets with additional fan cooling for low surface temperature
• Exclusive use of insulation materials without categorization according to EC Regulation No. 1272/2008 (CLP)
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller B510 resp. R7 for L 1/12 (5 programs with each 4 segments)
• Solid state relays provide for lownoise operation
• Defined application within the constraints of the operating instructions
• NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive
%
Nabertherm muffle furnace L 5/12/B510
The muffle furnaces L 1/12 - LT 40/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability. The muffle furnaces come equipped with either a flap door or lift door at no extra charge.
Standard Equipment
• Tmax 1100 °C or 1200 °C
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 40/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type N (1100 °C) or type S (1200 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• Optional flap door (L) which can be used as work platform or lift door (LT) with hot surface facing away from the operator
• Dual shell housing made of textured stainless steel sheets with additional fan cooling for low surface temperature
• Exclusive use of insulation materials without categorization according to EC Regulation No. 1272/2008 (CLP)
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller B510 resp. R7 for L 1/12 (5 programs with each 4 segments)
• Solid state relays provide for lownoise operation
• Defined application within the constraints of the operating instructions
• NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive
%
Nabertherm muffle furnace L 5/12/C550
The muffle furnaces L 1/12 - LT 40/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability. The muffle furnaces come equipped with either a flap door or lift door at no extra charge.
Standard Equipment
• Tmax 1100 °C or 1200 °C
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 40/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type N (1100 °C) or type S (1200 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• Optional flap door (L) which can be used as work platform or lift door (LT) with hot surface facing away from the operator
• Dual shell housing made of textured stainless steel sheets with additional fan cooling for low surface temperature
• Exclusive use of insulation materials without categorization according to EC Regulation No. 1272/2008 (CLP)
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller B510 resp. R7 for L 1/12 (5 programs with each 4 segments)
• Solid state relays provide for lownoise operation
• Defined application within the constraints of the operating instructions
• NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive
%
Nabertherm muffle furnace LT 9/11/B510
The muffle furnaces L 1/12 - LT 40/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability. The muffle furnaces come equipped with either a flap door or lift door at no extra charge.
Standard Equipment
• Tmax 1100 °C or 1200 °C
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 40/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type N (1100 °C) or type S (1200 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• Optional flap door (L) which can be used as work platform or lift door (LT) with hot surface facing away from the operator
• Dual shell housing made of textured stainless steel sheets with additional fan cooling for low surface temperature
• Exclusive use of insulation materials without categorization according to EC Regulation No. 1272/2008 (CLP)
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller B510 resp. R7 for L 1/12 (5 programs with each 4 segments)
• Solid state relays provide for lownoise operation
• Defined application within the constraints of the operating instructions
• NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive
%
Nabertherm muffle furnace LT 9/12/B510
The muffle furnaces L 1/12 - LT 40/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability. The muffle furnaces come equipped with either a flap door or lift door at no extra charge.
Standard Equipment
• Tmax 1100 °C or 1200 °C
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 40/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type N (1100 °C) or type S (1200 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• Optional flap door (L) which can be used as work platform or lift door (LT) with hot surface facing away from the operator
• Dual shell housing made of textured stainless steel sheets with additional fan cooling for low surface temperature
• Exclusive use of insulation materials without categorization according to EC Regulation No. 1272/2008 (CLP)
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller B510 resp. R7 for L 1/12 (5 programs with each 4 segments)
• Solid state relays provide for lownoise operation
• Defined application within the constraints of the operating instructions
• NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive
%
Nabertherm muffle furnace L 9/12/B510
The muffle furnaces L 1/12 - LT 40/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability. The muffle furnaces come equipped with either a flap door or lift door at no extra charge.
Standard Equipment
• Tmax 1100 °C or 1200 °C
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 40/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type N (1100 °C) or type S (1200 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• Optional flap door (L) which can be used as work platform or lift door (LT) with hot surface facing away from the operator
• Dual shell housing made of textured stainless steel sheets with additional fan cooling for low surface temperature
• Exclusive use of insulation materials without categorization according to EC Regulation No. 1272/2008 (CLP)
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller B510 resp. R7 for L 1/12 (5 programs with each 4 segments)
• Solid state relays provide for lownoise operation
• Defined application within the constraints of the operating instructions
• NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive
%
Nabertherm muffle furnace L 9/12/C550
The muffle furnaces L 1/12 - LT 40/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability. The muffle furnaces come equipped with either a flap door or lift door at no extra charge.
Standard Equipment
• Tmax 1100 °C or 1200 °C
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 40/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type N (1100 °C) or type S (1200 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• Optional flap door (L) which can be used as work platform or lift door (LT) with hot surface facing away from the operator
• Dual shell housing made of textured stainless steel sheets with additional fan cooling for low surface temperature
• Exclusive use of insulation materials without categorization according to EC Regulation No. 1272/2008 (CLP)
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller B510 resp. R7 for L 1/12 (5 programs with each 4 segments)
• Solid state relays provide for lownoise operation
• Defined application within the constraints of the operating instructions
• NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive
%
Nabertherm muffle furnace L 9/11/B510
The muffle furnaces L 9/11 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.

Standard Equipment
• Tmax 1100 °C
• Heating from two sides by ceramic heating plates for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With flap door (L)
• Dual shell housing made of textured stainless steel sheets with additional fan cooling for low surface temperature
• Exclusive use of insulation materials without categorization according to EC Regulation No. 1272/2008 (CLP)
• Adjustable air inlet integrated in door
• Exhaust air outlet in rear wall of furnace
• Solid state relays provide for lownoise operation
• Defined application within the constraints of the operating instructions
• Controller B510 (5 programs with each 4 segments)
• NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive
Options:
• Overtemperature limit controller
• Protective gas connection
• Hole for thermocouple in rear wall
• Hole for thermocouple in furnace door
• Process control and documentation via VCD software package for monitoring, documentation and control