Climate chamber
Climate chamber
All Products
Brand
Bandelin
Bimos
Binder
Düperthal
Esco
Fedegari
Fumex
Heidolph
HP Labortechnik
Julabo
Kirsch
Kühner
Liebherr
Miele
Nabertherm
Ohaus
Sigma
Stakpure
Vacuubrand
Waldner
Products
Autoclaves
Bioreactors
Safety storage cabinets
Centrifuges
CO₂ incubators
Distimatic automatic module
Documentation software
Extraction arms
Fluid aspiration systems
Heating circulators
Refrigerated / heating circulators
Incubators
Climate chambers
Laboratory freezers
Laboratory dishwashers
Laboratory refrigerators
Combined laboratory refrigerator-freezers
Laboratory chairs
Laboratory furniture
Laminar flow cabinets
Laboratory furnaces
Magnetic stirrers
Balances
Microbiological safety cabinets
Moisture analyzers
Growth chambers
Peristaltic pumps
Professional shakers
Shakers
Rotary evaporators
Overhead stirrers
Drying chambers and heating chambers
Test chambers
Ultrasonic baths
Ultrasonic cell disruptor
Ultrasonic baths
Ultra low temperature freezers
Vacuum drying chambers
Vacuum networks
Vacuum gauges and controllers
Vacuum pumps
Fume cupboards
Water baths
Water purification systems
Filters by category
%
Binder WIC 1 Walk-in-Chamber
The Binder Environmental Walk-in Chambers with either 6 m², 9 m² or 12 m² internal dimensions and 2,3 m height are an excellent choice for stability testing in Pharma, Food & Beverage, Cosmetics, Material Testing and many other fields of application.
In Pharma, the Binder Walk-in Chambers cover long-term and accelerated stability test conditions as specified in the ICH Q1A (R2) for new drug substances and drug products.
The walk-in chambers are designed and produced in Germany, and the temperature and environmental conditioners are made by Parameter Generation and Control in Black Mountain, NC USA. The chambers offer a wide range of features and benefits to perfectly meet requirements in stability testing.
Product features
• Long-term and accelerated stability tests according to the guidelines of ICH Q1R (R2)
• Temperature accuracy: ± 1.5°C
• Humidity range (% rH): 20...90
• Humidity accuracy: ± 2.5% RH
• High-efficiency insulation panels with a U-value of 0.21 W/m2K
• Motion sensor LED lighting
• Entire inner chamber made of stainless steel
• External service access to the conditioning unit
• Safety lockable door, which can always be opened from the inside
• Environmentally friendly refrigerant R450A
• Power supply: 230V / 50Hz, 11.5A
• Available accessories: shelving system, ramp
Compare
%
Binder WIC 2 Walk-in-Chamber
The Binder Environmental Walk-in Chambers with either 6 m², 9 m² or 12 m² internal dimensions and 2,3 m height are an excellent choice for stability testing in Pharma, Food & Beverage, Cosmetics, Material Testing and many other fields of application.
In Pharma, the Binder Walk-in Chambers cover long-term and accelerated stability test conditions as specified in the ICH Q1A (R2) for new drug substances and drug products.
The walk-in chambers are designed and produced in Germany, and the temperature and environmental conditioners are made by Parameter Generation and Control in Black Mountain, NC USA. The chambers offer a wide range of features and benefits to perfectly meet requirements in stability testing.
Product features
• Long-term and accelerated stability tests according to the guidelines of ICH Q1R (R2)
• Temperature accuracy: ± 1.5°C
• Humidity range (% rH): 20...90
• Humidity accuracy: ± 2.5% RH
• High-efficiency insulation panels with a U-value of 0.21 W/m2K
• Motion sensor LED lighting
• Entire inner chamber made of stainless steel
• External service access to the conditioning unit
• Safety lockable door, which can always be opened from the inside
• Environmentally friendly refrigerant R450A
• Power supply: 230V / 50Hz, 11.5A
• Available accessories: shelving system, ramp
Compare
%
Binder WIC 3 Walk-in-Chamber
The Binder Environmental Walk-in Chambers with either 6 m², 9 m² or 12 m² internal dimensions and 2,3 m height are an excellent choice for stability testing in Pharma, Food & Beverage, Cosmetics, Material Testing and many other fields of application.
In Pharma, the Binder Walk-in Chambers cover long-term and accelerated stability test conditions as specified in the ICH Q1A (R2) for new drug substances and drug products.
The walk-in chambers are designed and produced in Germany, and the temperature and environmental conditioners are made by Parameter Generation and Control in Black Mountain, NC USA. The chambers offer a wide range of features and benefits to perfectly meet requirements in stability testing.
Product features
• Long-term and accelerated stability tests according to the guidelines of ICH Q1R (R2)
• Temperature accuracy: ± 1.5°C
• Humidity range (% rH): 20...90
• Humidity accuracy: ± 2.5% RH
• High-efficiency insulation panels with a U-value of 0.21 W/m2K
• Motion sensor LED lighting
• Entire inner chamber made of stainless steel
• External service access to the conditioning unit
• Safety lockable door, which can always be opened from the inside
• Environmentally friendly refrigerant R450A
• Power supply: 230V / 50Hz, 11.5A
• Available accessories: shelving system, ramp
Compare
%
Binder KBF-S ECO 240 constant climate chamber with Peltier technology
Thanks to thermoelectric cooling technology with patented heat dissipation, the new KBF-S ECO climatic chamber is one of the most energy-efficient constant climate chambers on the market. The thermoelectric cooling technology means the KBF-S ECO series is also very quiet during operation.
Benefits
• Safe thanks to standard-compliant testing according to the ICH Q1A guideline, even with full load.
• Reliable thanks to failsafe operation without compromise.
• Smart, as a wide range of accessories makes it highly compatible for adaptation to specific customer requirements.
• Economical, as energy consumption is minimal thanks to optimized thermoelectric cooling.
Main features
• Temperature range: 0 °C to +70 °C (max. 24 °C under ambient temperature)
• Unit self-test for comprehensive status analysis
• Inner chamber made completely of stainless steel
• Humidity range: 10% to 80% RH
• APT.line™ preheating chamber technology
• Independent water supply via tank
• LCD to display temperature and humidity along with additional information and alarms
• Internal data logger, measured values can be read out in open format via USB
Compare
%
Binder KBF LQC 240 constant climate chambers with ICH-compliant light source and light dose control
The main advantage of the BINDER KBF LQC series is the patented light photometry for photostability tests. Two 3D spherical sensors control the light dosage of UV-A and visible light. Once the desired light dosage is achieved, the chamber switches off automatically.
Benefits
• Homogeneous climate conditions thanks to APT.line™ technology
• Automatic water and wastewater management
• Pressure humidification with fast response times
• Variable position and removable illumination cassettes
• ICH-compliant illumination for long-term stable test conditions
• Precise photometry with 3D ball-type sensors at the sample
Important characteristics
• Temperature range: 0 °C to +70 °C
• Temperature range with light: +10 °C to +60 °C
• Humidity range: 10 % to 80 % RH
• positionable illumination cassettes with ICH-compliant UV/Vis light source
• Independent light-dose control of UV-A and visible light with spherical sensors
• APT.line™ preheating chamber technology
• Humidity regulation with capacitive humidity sensor and vapor humidification
• Inner chamber made of stainless steel
• BINDER Multi Management Software APT-COM™ Basic Edition
• Intuitive touchscreen controller with time-segment and real-time programming
• Internal data logger, measured values can be read out in open format via USB
• Unit self-test for comprehensive status analysis
• Tight-sealing inner door made of safety glass (ESG)
• Avoidance of glass corrosion by special TIMELESS coating
• stainless steel racks
• Access port with silicone plug, 30 mm, left
• 4 stable castors, two with brakes
• Class 3.1 independent temperature safety device (DIN 12880) with visual and audible temperature alarm
• Computer interface: Ethernet
• Door heating
Compare
%
Binder KBF P 240 constant climate chambers with ICH-compliant light source
The KBF P constant climate chamber, equipped with ICH-compliant light source, is an expert when it comes to photostability tests and ensures clear test results in accordance with ICH Guideline Q1B. At the same time, the variable-position illumination cassettes offer homogeneous lighting conditions.
Benefits
• Homogeneous climate conditions thanks to APT.line™ technology
• Automatic water and wastewater management
• Pressure humidification with fast response times
• Variable position and removable illumination cassettes
• ICH-compliant illumination for long-term stable test conditions
Important characteristics
• Temperature range: 0 °C to +70 °C
• Temperature range with light: +10 °C to +60 °C
• Humidity range: 10 % to 80 % RH
• positionable illumination cassettes with ICH-compliant UV/Vis light source
• APT.line™ preheating chamber technology
• Humidity regulation with capacitive humidity sensor and vapor humidification
• Inner chamber made of stainless steel
• BINDER Multi Management Software APT-COM™ Basic Edition
• Intuitive touchscreen controller with time-segment and real-time programming
• Internal data logger, measured values can be read out in open format via USB
• Unit self-test for comprehensive status analysis
• Tight-sealing inner door made of safety glass (ESG)
• Avoidance of glass corrosion by special TIMELESS coating
• stainless steel racks
• Access port with silicone plug, 30 mm, left
• 4 stable castors, two with brakes
• Class 3.1 independent temperature safety device (DIN 12880) with visual and audible temperature alarm
• Computer interface: Ethernet
• Door heating
Compare
%
Binder KBF-S 115 standard climate chamber
The new Solid.Line KBF-S climate chamber is a custom-made solution for long-term testing and accelerated stability testing for pharmaceutical products in accordance with the ICH Q1A guideline. The corrosion-free and condensation-free interior also ensures exceptionally stable temperature and moisture levels, even when fully loaded.
Benefits
• Homogeneous climate conditions thanks to APT.line™ preheating chamber
• Standard-compliant testing according to ICH Q1A
• Precise temperature and humidity control
Important characteristics
• Temperature range: 0 °C to +70 °C
• Humidity range: 20% to 80% RH
• APT.line™ preheating chamber technology
• Humidity regulation with capacitive humidity sensor and steam humidification
• LCD to display temperature and humidity along with additional information and alarms
• Internal data logger, measured values can be read out in open format via USB
• Unit self-test for comprehensive status analysis
• Inner chamber made completely of stainless steel
• 2 stainless steel racks, incl. shelf supports
• Access port with silicone plug, 30 mm, left
• Robust twin casters with brakes, from 240 L
• Class 3.1 independent temperature safety device (DIN 12880) with visual and audible temperature alarm
• Computer interface: Ethernet
• Independent water supply via tank
Compare
%
Binder KMF 115 constant climate chamber
The BINDER KMF ensures absolutely constant test conditions throughout the testing area. A big advantage of this constant climate chamber is its low space requirement and flexibility in terms of water supply. The wide temperature and humidity range make this constant climate chamber ideally suited for stress testing series.
Benefits
• Homogeneous climate conditions thanks to APT.line™ technology
• Automatic water and wastewater management
• Humidification with fast response times
• Wide humidity range up to 98 % RH
• Long-term stress testing, e.g. at 85 °C / 85 % RH
Important characteristics
• Temperature range: -10 °C to +100 °C
• Humidity range: 10 % RH to 98 % RH
• APT.line™ preheating chamber technology
• Humidity regulation with capacitive humidity sensor and vapor humidification
• Inner chamber made of stainless steel
• BINDER Multi Management Software APT-COM™ Basic Edition
• Intuitive touchscreen controller with time-segment and real-time programming
• Internal data logger, measured values can be read out in open format via USB
• Unit self-test for comprehensive status analysis
• Tight-sealing inner door made of safety glass (ESG)
• Avoidance of glass corrosion by special TIMELESS coating
• 1 stainless steel rack
• Access port with silicone plug, 30 mm, left
• Class 3.1 independent temperature safety device (DIN 12880) with visual and audible temperature alarm
• Computer interface: Ethernet
• Door heating
Compare
%
Binder KBF 115 constant climate chamber
The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climate conditions. From programming to documentation, this constant climate chamber meets all critical requirements.
Benefits
• Homogeneous climate conditions thanks to APT.line™ technology
• Automatic water and wastewater management
• Pressure humidification with fast response times
Important characteristics
• Temperature range: 0 °C to +70 °C
• Humidity range: 10 % to 80 % RH
• APT.line™ preheating chamber technology
• Humidity regulation with capacitive humidity sensor and vapor humidification
• Intuitive touchscreen controller with time-segment and real-time programming
• BINDER Multi Management Software APT-COM™ Basic Edition
• Internal data logger, measured values can be read out in open format via USB
• Unit self-test for comprehensive status analysis
• Tight-sealing inner door made of safety glass (ESG)
• Avoidance of glass corrosion by special TIMELESS coating
• Inner chamber made of stainless steel
• 2 stainless steel racks
• Access port with silicone plug, 30 mm, left
• 4 stable castors, two with brakes, from 240 liters
• Class 3.1 independent temperature safety device (DIN 12880) with visual and audible temperature alarm
• Computer interface: Ethernet
• Door heating
Compare
%
Binder KBF-S ECO 400 constant climate chamber with Peltier technology
Thanks to thermoelectric cooling technology with patented heat dissipation, the new KBF-S ECO climatic chamber is one of the most energy-efficient constant climate chambers on the market. The thermoelectric cooling technology means the KBF-S ECO series is also very quiet during operation.
Benefits
• Safe thanks to standard-compliant testing according to the ICH Q1A guideline, even with full load.
• Reliable thanks to failsafe operation without compromise.
• Smart, as a wide range of accessories makes it highly compatible for adaptation to specific customer requirements.
• Economical, as energy consumption is minimal thanks to optimized thermoelectric cooling.
Main features
• Temperature range: 0 °C to +70 °C (max. 26 °C under ambient temperature)
• Unit self-test for comprehensive status analysis
• Inner chamber made completely of stainless steel
• Humidity range: 10% to 80% RH
• APT.line™ preheating chamber technology
• Independent water supply via tank
• LCD to display temperature and humidity along with additional information and alarms
• Internal data logger, measured values can be read out in open format via USB
Compare
%
Binder KBF P 720 constant climate chambers with ICH-compliant light source
The KBF P constant climate chamber, equipped with ICH-compliant light source, is an expert when it comes to photostability tests and ensures clear test results in accordance with ICH Guideline Q1B. At the same time, the variable-position illumination cassettes offer homogeneous lighting conditions.
Benefits
• Homogeneous climate conditions thanks to APT.line™ technology
• Automatic water and wastewater management
• Pressure humidification with fast response times
• Variable position and removable illumination cassettes
• ICH-compliant illumination for long-term stable test conditions
Important characteristics
• Temperature range: 0 °C to +70 °C
• Temperature range with light: +10 °C to +60 °C
• Humidity range: 10 % to 80 % RH
• positionable illumination cassettes with ICH-compliant UV/Vis light source
• APT.line™ preheating chamber technology
• Humidity regulation with capacitive humidity sensor and vapor humidification
• Inner chamber made of stainless steel
• BINDER Multi Management Software APT-COM™ Basic Edition
• Intuitive touchscreen controller with time-segment and real-time programming
• Internal data logger, measured values can be read out in open format via USB
• Unit self-test for comprehensive status analysis
• Tight-sealing inner door made of safety glass (ESG)
• Avoidance of glass corrosion by special TIMELESS coating
• stainless steel racks
• Access port with silicone plug, 30 mm, left
• 4 stable castors, two with brakes
• Class 3.1 independent temperature safety device (DIN 12880) with visual and audible temperature alarm
• Computer interface: Ethernet
• Door heating
Compare
%
Binder KBF-S 240 standard climate chamber
The new Solid.Line KBF-S climate chamber is a custom-made solution for long-term testing and accelerated stability testing for pharmaceutical products in accordance with the ICH Q1A guideline. The corrosion-free and condensation-free interior also ensures exceptionally stable temperature and moisture levels, even when fully loaded.
Benefits
• Homogeneous climate conditions thanks to APT.line™ preheating chamber
• Standard-compliant testing according to ICH Q1A
• Precise temperature and humidity control
Important characteristics
• Temperature range: 0 °C to +70 °C
• Humidity range: 20% to 80% RH
• APT.line™ preheating chamber technology
• Humidity regulation with capacitive humidity sensor and steam humidification
• LCD to display temperature and humidity along with additional information and alarms
• Internal data logger, measured values can be read out in open format via USB
• Unit self-test for comprehensive status analysis
• Inner chamber made completely of stainless steel
• 2 stainless steel racks, incl. shelf supports
• Access port with silicone plug, 30 mm, left
• Robust twin casters with brakes, from 240 L
• Class 3.1 independent temperature safety device (DIN 12880) with visual and audible temperature alarm
• Computer interface: Ethernet
• Independent water supply via tank
Compare
%
Binder KMF 240 constant climate chamber
The BINDER KMF ensures absolutely constant test conditions throughout the testing area. A big advantage of this constant climate chamber is its low space requirement and flexibility in terms of water supply. The wide temperature and humidity range make this constant climate chamber ideally suited for stress testing series.
Benefits
• Homogeneous climate conditions thanks to APT.line™ technology
• Automatic water and wastewater management
• Humidification with fast response times
• Wide humidity range up to 98 % RH
• Long-term stress testing, e.g. at 85 °C / 85 % RH
Important characteristics
• Temperature range: -10 °C to +100 °C
• Humidity range: 10 % RH to 98 % RH
• APT.line™ preheating chamber technology
• Humidity regulation with capacitive humidity sensor and vapor humidification
• Inner chamber made of stainless steel
• BINDER Multi Management Software APT-COM™ Basic Edition
• Intuitive touchscreen controller with time-segment and real-time programming
• Internal data logger, measured values can be read out in open format via USB
• Unit self-test for comprehensive status analysis
• Tight-sealing inner door made of safety glass (ESG)
• Avoidance of glass corrosion by special TIMELESS coating
• 1 stainless steel rack
• Access port with silicone plug, 30 mm, left
• Class 3.1 independent temperature safety device (DIN 12880) with visual and audible temperature alarm
• Computer interface: Ethernet
• Door heating
Compare
%
Binder KBF 240 constant climate chamber
The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climate conditions. From programming to documentation, this constant climate chamber meets all critical requirements.
Benefits
• Homogeneous climate conditions thanks to APT.line™ technology
• Automatic water and wastewater management
• Pressure humidification with fast response times
Important characteristics
• Temperature range: 0 °C to +70 °C
• Humidity range: 10 % to 80 % RH
• APT.line™ preheating chamber technology
• Humidity regulation with capacitive humidity sensor and vapor humidification
• Intuitive touchscreen controller with time-segment and real-time programming
• BINDER Multi Management Software APT-COM™ Basic Edition
• Internal data logger, measured values can be read out in open format via USB
• Unit self-test for comprehensive status analysis
• Tight-sealing inner door made of safety glass (ESG)
• Avoidance of glass corrosion by special TIMELESS coating
• Inner chamber made of stainless steel
• 2 stainless steel racks
• Access port with silicone plug, 30 mm, left
• 4 stable castors, two with brakes, from 240 liters
• Class 3.1 independent temperature safety device (DIN 12880) with visual and audible temperature alarm
• Computer interface: Ethernet
• Door heating
Compare
%
Binder KBF-S ECO 720 constant climate chamber with Peltier technology
Thanks to thermoelectric cooling technology with patented heat dissipation, the new KBF-S ECO climatic chamber is one of the most energy-efficient constant climate chambers on the market. The thermoelectric cooling technology means the KBF-S ECO series is also very quiet during operation.
Benefits
• Safe thanks to standard-compliant testing according to the ICH Q1A guideline, even with full load.
• Reliable thanks to failsafe operation without compromise.
• Smart, as a wide range of accessories makes it highly compatible for adaptation to specific customer requirements.
• Economical, as energy consumption is minimal thanks to optimized thermoelectric cooling.
Main features
• Temperature range: 0 °C to +70 °C (max. 24 °C under ambient temperature)
• Unit self-test for comprehensive status analysis
• Inner chamber made completely of stainless steel
• Humidity range: 10% to 80% RH
• APT.line™ preheating chamber technology
• Independent water supply via tank
• LCD to display temperature and humidity along with additional information and alarms
• Internal data logger, measured values can be read out in open format via USB
Compare
%
Binder KBF-S 720 standard climate chamber
The new Solid.Line KBF-S climate chamber is a custom-made solution for long-term testing and accelerated stability testing for pharmaceutical products in accordance with the ICH Q1A guideline. The corrosion-free and condensation-free interior also ensures exceptionally stable temperature and moisture levels, even when fully loaded.
Benefits
• Homogeneous climate conditions thanks to APT.line™ preheating chamber
• Standard-compliant testing according to ICH Q1A
• Precise temperature and humidity control
Important characteristics
• Temperature range: 0 °C to +70 °C
• Humidity range: 20% to 80% RH
• APT.line™ preheating chamber technology
• Humidity regulation with capacitive humidity sensor and steam humidification
• LCD to display temperature and humidity along with additional information and alarms
• Internal data logger, measured values can be read out in open format via USB
• Unit self-test for comprehensive status analysis
• Inner chamber made completely of stainless steel
• 2 stainless steel racks, incl. shelf supports
• Access port with silicone plug, 30 mm, left
• Robust twin casters with brakes, from 240 L
• Class 3.1 independent temperature safety device (DIN 12880) with visual and audible temperature alarm
• Computer interface: Ethernet
• Independent water supply via tank
Compare
%
Binder KMF 720 constant climate chamber
The BINDER KMF ensures absolutely constant test conditions throughout the testing area. A big advantage of this constant climate chamber is its low space requirement and flexibility in terms of water supply. The wide temperature and humidity range make this constant climate chamber ideally suited for stress testing series.
Benefits
• Homogeneous climate conditions thanks to APT.line™ technology
• Automatic water and wastewater management
• Humidification with fast response times
• Wide humidity range up to 98 % RH
• Long-term stress testing, e.g. at 85 °C / 85 % RH
Important characteristics
• Temperature range: -10 °C to +100 °C
• Humidity range: 10 % RH to 98 % RH
• APT.line™ preheating chamber technology
• Humidity regulation with capacitive humidity sensor and vapor humidification
• Inner chamber made of stainless steel
• BINDER Multi Management Software APT-COM™ Basic Edition
• Intuitive touchscreen controller with time-segment and real-time programming
• Internal data logger, measured values can be read out in open format via USB
• Unit self-test for comprehensive status analysis
• Tight-sealing inner door made of safety glass (ESG)
• Avoidance of glass corrosion by special TIMELESS coating
• 1 stainless steel rack
• Access port with silicone plug, 30 mm, left
• Class 3.1 independent temperature safety device (DIN 12880) with visual and audible temperature alarm
• Computer interface: Ethernet
• Door heating
Compare
%
Binder KBF 720 constant climate chamber
The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climate conditions. From programming to documentation, this constant climate chamber meets all critical requirements.
Benefits
• Homogeneous climate conditions thanks to APT.line™ technology
• Automatic water and wastewater management
• Pressure humidification with fast response times
Important characteristics
• Temperature range: 0 °C to +70 °C
• Humidity range: 10 % to 80 % RH
• APT.line™ preheating chamber technology
• Humidity regulation with capacitive humidity sensor and vapor humidification
• Intuitive touchscreen controller with time-segment and real-time programming
• BINDER Multi Management Software APT-COM™ Basic Edition
• Internal data logger, measured values can be read out in open format via USB
• Unit self-test for comprehensive status analysis
• Tight-sealing inner door made of safety glass (ESG)
• Avoidance of glass corrosion by special TIMELESS coating
• Inner chamber made of stainless steel
• 2 stainless steel racks
• Access port with silicone plug, 30 mm, left
• 4 stable castors, two with brakes, from 240 liters
• Class 3.1 independent temperature safety device (DIN 12880) with visual and audible temperature alarm
• Computer interface: Ethernet
• Door heating
Compare
%
Binder KBF-S ECO 1020 constant climate chamber with Peltier technology
Thanks to thermoelectric cooling technology with patented heat dissipation, the new KBF-S ECO climatic chamber is one of the most energy-efficient constant climate chambers on the market. The thermoelectric cooling technology means the KBF-S ECO series is also very quiet during operation.
Benefits
• Safe thanks to standard-compliant testing according to the ICH Q1A guideline, even with full load.
• Reliable thanks to failsafe operation without compromise.
• Smart, as a wide range of accessories makes it highly compatible for adaptation to specific customer requirements.
• Economical, as energy consumption is minimal thanks to optimized thermoelectric cooling.
Main features
• Temperature range: 0 °C to +70 °C (max. 24 °C under ambient temperature)
• Unit self-test for comprehensive status analysis
• Inner chamber made completely of stainless steel
• Humidity range: 10% to 80% RH
• APT.line™ preheating chamber technology
• Independent water supply via tank
• LCD to display temperature and humidity along with additional information and alarms
• Internal data logger, measured values can be read out in open format via USB
Compare
%
Binder KBF-S 1020 UL standard climate chamber
The new Solid.Line KBF-S climate chamber is a custom-made solution for long-term testing and accelerated stability testing for pharmaceutical products in accordance with the ICH Q1A guideline. The corrosion-free and condensation-free interior also ensures exceptionally stable temperature and moisture levels, even when fully loaded.
Benefits
• Homogeneous climate conditions thanks to APT.line™ preheating chamber
• Standard-compliant testing according to ICH Q1A
• Precise temperature and humidity control
Important characteristics
• Temperature range: 0 °C to +70 °C
• Humidity range: 20% to 80% RH
• APT.line™ preheating chamber technology
• Humidity regulation with capacitive humidity sensor and steam humidification
• LCD to display temperature and humidity along with additional information and alarms
• Internal data logger, measured values can be read out in open format via USB
• Unit self-test for comprehensive status analysis
• Inner chamber made completely of stainless steel
• 2 stainless steel racks, incl. shelf supports
• Access port with silicone plug, 30 mm, left
• Robust twin casters with brakes, from 240 L
• Class 3.1 independent temperature safety device (DIN 12880) with visual and audible temperature alarm
• Computer interface: Ethernet
• Independent water supply via tank
Compare