English
English
Magyar
Home
About us
Shop By Products
Shop By Brand
Contact us
blog
My Cart
Sign in
Public pricelist HUF
Prev
1
2
3
4
5
6
7
Next
Sort by
Relevance
Catalog price: High to Low
Catalog price: Low to High
Name - A to Z
Name - Z to A
Product Sequence Low to High
Product Sequence High to Low
Products
Drying and heating chamber
Drying and heating chamber
All Products
Brand
Bandelin
Bimos
Binder
Düperthal
Esco
Fedegari
Fumex
Heidolph
HP Labortechnik
Julabo
Kirsch
Kühner
Liebherr
Miele
Nabertherm
Ohaus
Sigma
Stakpure
Vacuubrand
Waldner
Products
Autoclaves
Bioreactors
Safety storage cabinets
Centrifuges
CO₂ incubators
Distimatic automatic module
Documentation software
Extraction arms
Fluid aspiration systems
Heating circulators
Refrigerated / heating circulators
Incubators
Climate chambers
Laboratory freezers
Laboratory dishwashers
Laboratory refrigerators
Combined laboratory refrigerator-freezers
Laboratory chairs
Laboratory furniture
Laminar flow cabinets
Laboratory furnaces
Magnetic stirrers
Balances
Microbiological safety cabinets
Moisture analyzers
Growth chambers
Peristaltic pumps
Professional shakers
Shakers
Rotary evaporators
Overhead stirrers
Drying chambers and heating chambers
Test chambers
Ultrasonic baths
Ultrasonic cell disruptor
Ultrasonic baths
Ultra low temperature freezers
Vacuum drying chambers
Vacuum networks
Vacuum gauges and controllers
Vacuum pumps
Fume cupboards
Water baths
Water purification systems
Filters by category
%
Nabertherm catalytic converter for muffle furnaces
Organic components are catalytically cleaned at about 600 °C, broken into carbon dioxide and water vapour. Irritating odors are thus largely eliminated. The B500 - P580 controllers can be used to switch the catalytic converter automatically (not for models L(T) 9/14, L(T) 15.., L 1/12, LE 1/11, LE 2/11).*
* Note: If other controller types are used an adapter cable for connection to mains supply has to be ordered separately. The device will be activated by plugging in the socket.
Compare
%
Binder ED 720 drying and heating chambers with natural convection
The strengths of a BINDER ED series drying chamber include routine drying and sterilization tasks up to 300 °C. Thanks to the natural convection, all thermal processes which use this drying chamber are highly efficient. The ED series ensures fast, uniform drying.
Benefits
• Best energy efficiency on the market
• Excellent temporal and spatial temperature accuracy
• USB connection for recording data
• Temperature range up to +300 °C
Important characteristics
• Temperature range: +5 °C above ambient temperature to +300 °C
• Up to 30% lower energy consumption compared to conventional units on the market
• High temperature accuracy thanks to APT.line™ technology
• Natural convection
• Controller with LCD display
• Electromechanical control of the exhaust air flap
• 2 chrome-plated racks
• Units up to 115 liters are stackable
• Class 2 integrated independent adjustable temperature safety device (DIN 12880) with visual alarm
• Ergonomic handle design
• USB port for recording data
Compare
%
Nabertherm chimney with fan for muffle furnaces
Exhaust gases are better removed from the furnace and discharged. The B500 - P580 controllers can be used to activate the fan automatically (not for models L(T) 15.., L 1/12, LE 1/11, LE 2/11).
* Note: If other controller types are used an adapter cable for connection to mains supply has to be ordered separately. The device will be activated by plugging in the socket.
Compare
%
Nabertherm L 3/11/C550 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.
Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type N (1100 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With flap door (L)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation C550
• Solid state relays provide for lownoise operation
Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door
Compare
%
Nabertherm LV 5/11/B510 ashing furnace
Ashing furnace LV(T) .. 11 is designed especially for ashing processes to 1050 °C in the laboratory. Applications include determining loss on ignition, ashing food and plastics for subsequent substance analysis. A special fresh-air and exhaust air system ensures that the air is replaced 6 times per minute so that there is always sufficient oxygen for the ashing process. Incoming air passes the furnace heating and is pre-heated to ensure good temperature uniformity.
Standard Equipment
• Heating from two sides
• Ceramic heating plates with integral heating element which is safeguarded, and easy to replace
• Air exchange of more than 6 times per minute
• Good temperature uniformity due to preheating of incoming air, temperature uniformity according to DIN 17052-1 to +/− 10 °C in the defined empty work area (from 550 °C)
• Dual shell housing made of textured stainless steel sheets with additional fan cooling for low surface temperature
• Exclusive use of insulation materials without categorization according to EC Regulation No. 1272/2008 (CLP)
• Suitable for many standardized ashing processes according to ISO, ASTM, EN, and DIN
• With flap door (LV)
• Solid state relays provide for lownoise operation
• Controller with touch operation B510 (5 programs with each 4 segments)
Option
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Port for thermocouple in the rear wall or in the furnace door
Compare
%
Nabertherm L 9/13/B510 muffle furnace with brick insulation
Heating elements on support tubes radiating freely into the furnace chamber provide for particularly short heating times for these muffle furnaces. Thanks to their robust lightweight refractory brick insulation, they can reach a maximum working temperature of 1300 °C. These muffle furnaces thus represent an interesting alternative to the familiar L(T) ../12 models, when you need a higher application temperature.
Standard Equipment
• Heating from two sides
• Heating elements on support tubes ensure free heat radiation and a long service life
• Multi-layer insulation with robust lightweight refractory bricks in the furnace chamber
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• With flap door (L)
• Adjustable air inlet in the furnace door
• Exhaust air outlet in rear wall of furnace
• Solid state relays provide for lownoise operation
• Controller with touch operation B510 (5 programs with each 4 segments)
Option
• Chimney, chimney with fan or catalytic converter
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door
Compare
%
Nabertherm charging plate N 31/H
We recommend these accessories for applications up to 1100 °C to protect the furnace floor, especially if a charging cart is used.
• Tmax 1100 °C
• Three raised edges
• Heat-resistant alloy 314 (AISI)/(DIN material no. 1.4841)
• Outer dimensions in mm (WxDxH 340x390x30)
Compare
%
Nabertherm L 3/12/B510 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.
Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type S (1200 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With flap door (L)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation B510 (5 programs with each 4 segments)
• Solid state relays provide for lownoise operation
Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door
Compare
%
Nabertherm LV 5/11/C550 ashing furnace
Ashing furnace LV ../11 is designed especially for ashing processes to 1050 °C in the laboratory. Applications include determining loss on ignition, ashing food and plastics for subsequent substance analysis. A special fresh-air and exhaust air system ensures that the air is replaced 6 times per minute so that there is always sufficient oxygen for the ashing process. Incoming air passes the furnace heating and is pre-heated to ensure good temperature uniformity.
Standard Equipment
• Heating from two sides
• Ceramic heating plates with integral heating element which is safeguarded, and easy to replace
• Air exchange of more than 6 times per minute
• Good temperature uniformity due to preheating of incoming air, temperature uniformity according to DIN 17052-1 to +/− 10 °C in the defined empty work area (from 550 °C)
• Dual shell housing made of textured stainless steel sheets with additional fan cooling for low surface temperature
• Exclusive use of insulation materials without categorization according to EC Regulation No. 1272/2008 (CLP)
• Suitable for many standardized ashing processes according to ISO, ASTM, EN, and DIN
• With flap door (LV)
• Solid state relays provide for lownoise operation
• Controller C550 (10 programs with each 20 segments)
Options
• Overtemperature limit controller
• Hole for thermocouple in rear wall
• Hole for thermocouple in furnace door
Compare
%
Nabertherm L 9/13/C550 muffle furnace with brick insulation
Heating elements on support tubes radiating freely into the furnace chamber provide for particularly short heating times for these muffle furnaces. Thanks to their robust lightweight refractory brick insulation, they can reach a maximum working temperature of 1300 °C. These muffle furnaces thus represent an interesting alternative to the familiar L(T) ../12 models, when you need a higher application temperature.
Standard Equipment
• Heating from two sides
• Heating elements on support tubes ensure free heat radiation and a long service life
• Multi-layer insulation with robust lightweight refractory bricks in the furnace chamber
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• With flap door (L)
• Adjustable air inlet in the furnace door
• Exhaust air outlet in rear wall of furnace
• Solid state relays provide for lownoise operation
• With Controller C550 (10 programs / 20 steps)
Option
• Chimney, chimney with fan or catalytic converter
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door
Compare
%
Nabertherm charging plate N 87/H
We recommend these accessories for applications up to 1100 °C to protect the furnace floor, especially if a charging cart is used.
• Tmax 1100 °C
• Three raised edges
• Heat-resistant alloy 314 (AISI)/(DIN material no. 1.4841)
• Outer dimensions in mm (WxDxH 340x1040x30)
Compare
%
Nabertherm L 3/12/C550 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.
Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type S (1200 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With flap door (L)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation C550
• Solid state relays provide for lownoise operation
Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door
Compare
%
Nabertherm LVT 9/11/B510 ashing furnace
Ashing furnace LV(T) .. 11 is designed especially for ashing processes to 1050 °C in the laboratory. Applications include determining loss on ignition, ashing food and plastics for subsequent substance analysis. A special fresh-air and exhaust air system ensures that the air is replaced 6 times per minute so that there is always sufficient oxygen for the ashing process. Incoming air passes the furnace heating and is pre-heated to ensure good temperature uniformity.
Standard Equipment
• Heating from two sides
• Ceramic heating plates with integral heating element which is safeguarded, and easy to replace
• Air exchange of more than 6 times per minute
• Good temperature uniformity due to preheating of incoming air, temperature uniformity according to DIN 17052-1 to +/− 10 °C in the defined empty work area (from 550 °C)
• Dual shell housing made of textured stainless steel sheets with additional fan cooling for low surface temperature
• Exclusive use of insulation materials without categorization according to EC Regulation No. 1272/2008 (CLP)
• Suitable for many standardized ashing processes according to ISO, ASTM, EN, and DIN
• With lift door (LVT)
• Solid state relays provide for lownoise operation
• Controller with touch operation B510 (5 programs with each 4 segments)
Option
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Port for thermocouple in the rear wall or in the furnace door
Compare
%
Nabertherm LT 15/13/B510 muffle furnace with brick insulation
Heating elements on support tubes radiating freely into the furnace chamber provide for particularly short heating times for these muffle furnaces. Thanks to their robust lightweight refractory brick insulation, they can reach a maximum working temperature of 1300 °C. These muffle furnaces thus represent an interesting alternative to the familiar L(T) ../12 models, when you need a higher application temperature.
Standard Equipment
• Heating from two sides
• Heating elements on support tubes ensure free heat radiation and a long service life
• Multi-layer insulation with robust lightweight refractory bricks in the furnace chamber
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• With lift door (LT)
• Adjustable air inlet in the furnace door
• Exhaust air outlet in rear wall of furnace
• Solid state relays provide for lownoise operation
• Controller with touch operation B510 (5 programs with each 4 segments)
Option
• Chimney, chimney with fan or catalytic converter
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door
Compare
%
Nabertherm collecting Pan, Steel for L..3
• Tmax 1100 °C
• Dimensions 150 x 140 x 20 mm
• For models L 3, LT 3, LV 3, LVT 3
Compare
%
Nabertherm LT 5/11/B510 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.
Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type N (1100 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With lift door (LT)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation B510 (5 programs with each 4 segments)
• Solid state relays provide for lownoise operation
Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door
Compare
%
Nabertherm LVT 9/11/C550 ashing furnace
Ashing furnace LV(T) .. 11 is designed especially for ashing processes to 1050 °C in the laboratory. Applications include determining loss on ignition, ashing food and plastics for subsequent substance analysis. A special fresh-air and exhaust air system ensures that the air is replaced 6 times per minute so that there is always sufficient oxygen for the ashing process. Incoming air passes the furnace heating and is pre-heated to ensure good temperature uniformity.
Standard Equipment
• Heating from two sides
• Ceramic heating plates with integral heating element which is safeguarded, and easy to replace
• Air exchange of more than 6 times per minute
• Good temperature uniformity due to preheating of incoming air, temperature uniformity according to DIN 17052-1 to +/− 10 °C in the defined empty work area (from 550 °C)
• Dual shell housing made of textured stainless steel sheets with additional fan cooling for low surface temperature
• Exclusive use of insulation materials without categorization according to EC Regulation No. 1272/2008 (CLP)
• Suitable for many standardized ashing processes according to ISO, ASTM, EN, and DIN
• With lift door (LVT)
• Solid state relays provide for lownoise operation
• Controller C550 (10 programs with each 20 segments)
Option
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Port for thermocouple in the rear wall or in the furnace door
Compare
%
Nabertherm LT 15/13/C550 muffle furnace with brick insulation
Heating elements on support tubes radiating freely into the furnace chamber provide for particularly short heating times for these muffle furnaces. Thanks to their robust lightweight refractory brick insulation, they can reach a maximum working temperature of 1300 °C. These muffle furnaces thus represent an interesting alternative to the familiar L(T) ../12 models, when you need a higher application temperature.
Standard Equipment
• Heating from two sides
• Heating elements on support tubes ensure free heat radiation and a long service life
• Multi-layer insulation with robust lightweight refractory bricks in the furnace chamber
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• With lift door (LT)
• Adjustable air inlet in the furnace door
• Exhaust air outlet in rear wall of furnace
• Solid state relays provide for lownoise operation
• With Controller C550 (10 programs / 20 steps)
Option
• Chimney, chimney with fan or catalytic converter
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door
Compare
%
Nabertherm collecting Pan, Steel for L..5
• Tmax 1100 °C
• Dimensions 190 x 170 x 20 mm
• For models LE 4, LE 6, L 5, LT 5, LV 5, LVT 5
Compare
%
Nabertherm LT 5/11/C550 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.
Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type N (1100 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With lift door (LT)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation C550
• Solid state relays provide for lownoise operation
Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door
Compare
Prev
1
2
3
4
5
6
7
Next