Drying and heating chamber

Drying ovens, heating chambers, and laboratory furnaces provide controlled and uniform temperature conditions for the treatment of samples and materials. They can be used for drying, sample preparation, material testing, thermal stress testing, as well as high-temperature annealing and ashing applications. Their precise and reliable operation contributes to reproducible results.

Filters by category

%
Nabertherm collecting Pan, Steel for L1/LE1
• Tmax 1100 °C
• Dimensions 85 x 100 x 20 mm
• For models L 1, LE 1
%
Nabertherm LT 9/11/B510 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.

Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type N (1100 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With lift door (LT)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation B510 (5 programs with each 4 segments)
• Solid state relays provide for lownoise operation

Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door

%
Nabertherm ribbed Plate, Ceramic for L..15
• Tmax 1200 °C
• Dimensions 340 x 220 x 12.7 mm
• For models L 15, LT 15, LV 15, LVT 15, N 11
%
Nabertherm LT 9/11/C550 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.

Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type N (1100 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With lift door (LT)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation C550
• Solid state relays provide for lownoise operation

Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door

%
Nabertherm ribbed Plate, Ceramic for L..3
• Tmax 1200 °C
• Dimensions 150 x 140 x 12.7 mm
• For models L 3, LT 3, LV 3, LVT 3
%
Nabertherm LT 9/12/B510 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.

Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type S (1200 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With lift door (LT)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation B510 (5 programs with each 4 segments)
• Solid state relays provide for lownoise operation

Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door

%
Nabertherm ribbed Plate, Ceramic for L..5/LE6
• Tmax 1200 °C
• Dimensions 190 x 170 x 12.7 mm
• For models LE 4, LE 6, L 5, LT 5, LV 5, LVT 5
%
Nabertherm LT 9/12/C550 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.

Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type S (1200 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With lift door (LT)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation C550
• Solid state relays provide for lownoise operation

Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door

%
Nabertherm ribbed Plate, Ceramic for L..9
• Tmax 1200 °C
• Dimensions 240 x 220 x 12.7 mm
• For models L 9, LT 9, LV 9, LVT 9, N 7
%
Nabertherm L 9/11/B510 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.

Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type N (1100 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With flap door (L)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation B510 (5 programs with each 4 segments)
• Solid state relays provide for lownoise operation

Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door
%
Nabertherm collecting Pan, Ceramic for L..3
• Tmax 1300 °C
• Dimensions 150 x 140 x 20 mm
• For models L 3, LT 3, LV 3, LVT 3
%
Nabertherm L 9/11/C550 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.

Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type N (1100 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With flap door (L)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation C550
• Solid state relays provide for lownoise operation

Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door

%
Nabertherm collecting Pan, Ceramic for L..5/LE6
• Tmax 1300 °C
• Dimensions 190 x 170 x 20 mm
• For models LE 4, LE 6, L 5, LT 5, LV 5, LVT 5
%
Nabertherm L 9/12/B510 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.

Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type S (1200 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With flap door (L)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation B510 (5 programs with each 4 segments)
• Solid state relays provide for lownoise operation

Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door

%
Nabertherm collecting Pan, Ceramic for L..9
• Tmax 1300 °C
• Dimensions 240 x 220 x 20 mm
• For models L 9, LT 9, LV 9, LVT 9, N 7
%
Nabertherm L 9/12/C550 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.

Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type S (1200 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With flap door (L)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation C550
• Solid state relays provide for lownoise operation

Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door

%
Nabertherm ribbed Plate, Ceramic for L..24
• Tmax 1200 °C
• Dimensions 340 x 270 x 12.7 mm
• For models L 24, LT 24
%
Nabertherm LT 15/11/B510 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.

Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type N (1100 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With lift door (LT)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation B510 (5 programs with each 4 segments)
• Solid state relays provide for lownoise operation

Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door

%
Nabertherm ribbed Plate, Ceramic for L..40
• Tmax 1200 °C
• Dimensions 490 x 310 x 12.7 mm
• For models L 40, LT 40
%
Nabertherm LT 15/11/C550 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.

Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type N (1100 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With lift door (LT)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation C550
• Solid state relays provide for lownoise operation

Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door