Liebherr SRPv laboratory refrigerators

Liebherr SRPv laboratory refrigeration units provide reliable and precise cooling in critical research and storage environments. In addition to high energy efficiency, they offer an advanced control system to maintain constant and accurate temperatures. They are ideal for medical, pharmaceutical, and scientific institutions.

%
Liebherr SRPvh 6501 heavy-duty fridge
Laboratory refrigerators and freezers are expected to provide the highest levels of safety and reliability. Precise electronic control, fan-assisted cooling, and highly efficient insulation result in outstanding energy efficiency, ensuring low operating costs and environmental protection. Advanced components and precise regulation work together to ensure optimal storage of materials.

Product Features

• Fan-assisted cooling system
• Automatic defrost
• Temperature range: -2 °C to +16 °C

Easy Operation

• Built-in handle along the full height of the door
• 2.4” color electronic control panel with touch & swipe function
• Easy-to-clean stainless steel interior lining
• Integrated, flush-mounted interior lighting (vertical, full-height side LED lighting)

Safety and Reliability

• Temperature stability up to: ±3 °C
• VCC variable speed compressor
The variable-speed compressors always provide the appropriate performance. This results in reduced energy consumption and increased temperature stability.
• Warning signal in case of malfunction: optical and acoustic
• SafetyDevice: prevents the temperature from dropping below +2 °C to avoid freezing
• PT1000 product temperature sensor
In addition to the built-in control sensor, another temperature sensor is available for measuring the simulated product temperature. The value measured by the product temperature sensor can be displayed on the screen, calibrated, and used as the reference for the device's alarm function. This ensures safer storage based on real product temperature values.
• Power failure alarm
In case of a power outage, the built-in battery maintains power for at least twelve hours and immediately activates an audible and visual alarm. Additional indication of when the power outage started and the maximum temperature reached.
• LightAlarm
In case of uncontrolled temperature rise, a door left open, or another issue, the internal lighting of the device starts to flash.
• Alarm history: Easy quality control
Logging important data from the last 10 alarms (e.g., date or maximum temperature) for the final quality assessment of stored goods.
• Built-in data logger: Trackable for years
Complete traceability independent of monitoring systems with up to 5 years of logging for temperature profiles, alarm history, and service information. Stored data can be retrieved via the USB port.
• The door automatically closes if opened at less than a 90° angle.
• Probe access: 1 x Ø 12 mm
• Electronic locking system: Protects against unauthorized access with locking/unlocking via PIN code or remote control.
• SmartLock: Automatic door locking in case of temperature alarm, only accessible by authorized personnel.
• Long lifespan

Compliance and Documentation

• DIN 13277 and IEC 61010-2-011 compliance
Liebherr laboratory and pharmaceutical refrigeration units meet all the features and performance criteria necessary for full compliance with DIN 13277. This standard defines requirements and test procedures for cooling and freezing equipment used in laboratories and for drug storage.
• Temperature distribution and consistency according to IEC 60068-3
• Safety according to IEC 61010-2-011
• Temperature setting (calibration)
• Logging of minimum/maximum temperature values
• Integrated connectivity (LAN or WiFi for BMS or SmartMonitoring systems)

Technical Data

• Gross/net volume: 614/480 L
• External dimensions (W/D/H) mm: 697/867/2135
• Internal dimensions (W/D/H) mm: 489/638/1470
• White, stainless steel exterior casing
• Door/Cover material: steel
• Adjustable shelves: 4 pcs
• Shelf material: steel with plastic coating
• Usable shelf size (W/D) mm: 480 / 638
• Shelf load capacity: 60 kg
• Door opening direction: right, reversible
• Laboratory refrigerators and freezers are expected to provide the highest levels of safety and reliability. Precise electronic control, fan-assisted cooling, and highly efficient insulation result in outstanding energy efficiency, ensuring low operating costs and environmental protection. Advanced components and precise regulation work together to ensure optimal storage of materials.
• Product Features
• Fan-assisted cooling system
• Automatic defrost
• Temperature range: -2 °C to +16 °C
• Easy Operation
• Built-in handle along the full height of the door
• 2.4” color electronic control panel with touch & swipe function
• Easy-to-clean stainless steel interior lining
• Integrated, flush-mounted interior lighting (vertical, full-height side LED lighting)
• Safety and Reliability
• Temperature stability up to: ±3 °C
• VCC variable speed compressor
• The variable-speed compressors always provide the appropriate performance. This results in reduced energy consumption and increased temperature stability.
• Warning signal in case of malfunction: optical and acoustic
• SafetyDevice: prevents the temperature from dropping below +2 °C to avoid freezing
• PT1000 product temperature sensor
• In addition to the built-in control sensor, another temperature sensor is available for measuring the simulated product temperature. The value measured by the product temperature sensor can be displayed on the screen, calibrated, and used as the reference for the device's alarm function. This ensures safer storage based on real product temperature values.
• Power failure alarm
• In case of a power outage, the built-in battery maintains power for at least twelve hours and immediately activates an audible and visual alarm. Additional indication of when the power outage started and the maximum temperature reached.
• LightAlarm
• In case of uncontrolled temperature rise, a door left open, or another issue, the internal lighting of the device starts to flash.
• Alarm history: Easy quality control
• Logging important data from the last 10 alarms (e.g., date or maximum temperature) for the final quality assessment of stored goods.
• Built-in data logger: Trackable for years
• Complete traceability independent of monitoring systems with up to 5 years of logging for temperature profiles, alarm history, and service information. Stored data can be retrieved via the USB port.
• The door automatically closes if opened at less than a 90° angle.
• Probe access: 1 x Ø 12 mm
• Electronic locking system: Protects against unauthorized access with locking/unlocking via PIN code or remote control.
• SmartLock: Automatic door locking in case of temperature alarm, only accessible by authorized personnel.
• Long lifespan
• Compliance and Documentation
• DIN 13277 and IEC 61010-2-011 compliance
• Liebherr laboratory and pharmaceutical refrigeration units meet all the features and performance criteria necessary for full compliance with DIN 13277. This standard defines requirements and test procedures for cooling and freezing equipment used in laboratories and for drug storage.
• Temperature distribution and consistency according to IEC 60068-3
• Safety according to IEC 61010-2-011
• Temperature setting (calibration)
• Logging of minimum/maximum temperature values
• Integrated connectivity (LAN or WiFi for BMS or SmartMonitoring systems)
• Technical Data
• Gross/net volume: 614/480 L
• External dimensions (W/D/H) mm: 697/867/2135
• Internal dimensions (W/D/H) mm: 489/638/1470
• White, stainless steel exterior casing
• Door/casing material: steel
• Adjustable shelves: 4 pcs
• Shelf material: steel with plastic coating
• Usable shelf size (W/D) mm: 480 / 638
• Shelf load capacity: 60 kg
• Door opening direction: right, reversible
• Castors with arrestor at the front, fixed castors at the rear
• Gross/net weight: 148/130 kg
• Annual energy consumption: 172 kWh
• Ambient temperature: +10 °C - +35 °C
• Heat emission: 305 kJ/h
• Refrigerant: R 600a
• Noise level: 60 dB(A)
• Frequency/voltage: 50/60 Hz / 220-240 V~
• Gross/net weight: 148/130 kg
• Annual energy consumption: 172 kWh
• Ambient temperature: +10 °C - +35 °C
• Heat emission: 305 kJ/h
• Refrigerant: R 600a
• Noise level: 60 dB(A)
• Frequency/voltage: 50/60 Hz / 220-240 V~
%
Liebherr SRPvg 6501 heavy-duty fridge
Laboratory refrigerators and freezers are expected to provide the highest levels of safety and reliability. Precise electronic control, fan-assisted cooling, and highly efficient insulation result in outstanding energy efficiency, ensuring low operating costs and environmental protection. Advanced components and precise regulation ensure optimal storage of materials.


Product Features

Easy Operation
User-friendly solutions for daily use

• Built-in handle along the full height of the door
• Monochrome electronic control panel with 3 touch buttons
• Easy-to-clean stainless steel interior lining
• The door stays open at angles greater than 90°
• Flush-mounted interior ceiling LED lighting

Compliance and Documentation
Built-in safety features to protect sensitive materials

• Temperature setting (calibration)
• Logging of minimum/maximum temperature values
The recorded minimum and maximum internal temperatures are saved and can be easily read from the display.
• Connectivity available as an upgrade (LAN or WiFi for BMS or SmartMonitoring systems)
• Standard compliance: IEC 60068-3, IEC 61010-2-011

Safety and Reliability
Reliable storage thanks to consistent cooling performance, even in extreme ambient temperature conditions

• Temperature stability up to: ±3 °C (refrigerator) / ±5 °C (freezer)
• Alarm relay
Alarm transmission to the monitoring system ensures no deviations go unnoticed.
• The door automatically closes if opened at less than a 90° angle.
• Probe access opening: 10 mm in diameter
• Mechanical door lock
• Long lifespan

Technical Data

• Gross/net volume: 614/480 L
• External dimensions (W/D/H) mm: 697/867/2135
• Internal dimensions (W/D/H) mm: 489/638/1470
• Energy consumption/year: 178 kWh
• Ambient temperature: +10 °C to +35 °C
• Heat emission: 305 kJ/h
• Refrigerant: R 290
• Noise level: 60 dB(A)
• Frequency/voltage: 50 Hz / 220-240 V~
• Fan-assisted cooling system
• Automatic defrost
• Temperature range: -2 °C to +16 °C
• External casing/color: steel / white
• Interior lining: chrome-nickel steel (1.4301 / AISI 304)
• Door/Cover material: steel
• Network connectivity via SmartModule, available as an upgrade
• WLAN/LAN connection: optional
• Adjustable shelves: 4
• Shelf material: steel with plastic coating
• Usable shelf size (W/D) mm: 480 / 638 mm
• Shelf load capacity: 60 kg
• Castors with arrestor at the front, fixed castors at the rear
• Probe access: 1 x Ø 12 mm
• Door opening direction: right, reversible
• Gross/net weight: 148/130 kg
%
Liebherr SRPvh 6511 heavy-duty fridge
Laboratory refrigerators and freezers are expected to provide the highest levels of safety and reliability. Precise electronic control, fan-assisted cooling, and highly efficient insulation result in outstanding energy efficiency, ensuring low operating costs and environmental protection. Advanced components and precise regulation ensure optimal storage of materials.

Product Features

• Fan-assisted cooling system
• Automatic defrost
• Temperature range: 0 °C to +16 °C

Easy Operation

• Built-in handle along the full height of the door
• 2.4” color electronic control panel with touch & swipe function
• Easy-to-clean stainless steel interior lining
• Flush-mounted interior lighting (vertical, full-height side LED lighting)

Safety and Reliability

• Temperature stability up to: ±3 °C
• VCC variable speed compressor
The variable-speed compressors always provide the appropriate performance. This results in reduced energy consumption and increased temperature stability.
• Warning signal in case of malfunction: optical and acoustic
• SafetyDevice: prevents the temperature from dropping below +2 °C to avoid freezing
• PT1000 product temperature sensor
In addition to the built-in control sensor, another temperature sensor is available for measuring the simulated product temperature. The value measured by the product temperature sensor can be displayed on the screen, calibrated, and used as the reference for the device's alarm function, ensuring safer storage based on real product temperature values.
• Power failure alarm
In case of a power outage, the built-in battery maintains power for at least twelve hours and immediately activates an audible and visual alarm. Additional indication of when the power outage started and the maximum temperature reached.
• LightAlarm
In case of uncontrolled temperature rise, a door left open, or another issue, the internal lighting of the device starts to flash.
• Alarm history: Easy quality control
Logging important data from the last 10 alarms (e.g., date or maximum temperature) for the final quality assessment of stored goods.
• Built-in data logger: Trackable for years
Complete traceability independent of monitoring systems with up to 5 years of logging for temperature profiles, alarm history, and service information. Stored data can be retrieved via the USB port.
• The door automatically closes if opened at less than a 90° angle.
• Probe access: 1 x Ø 12 mm
• Electronic locking system: Protects against unauthorized access with locking/unlocking via PIN code or remote control.
• SmartLock: Automatic door locking in case of temperature alarm, only accessible by authorized personnel.
• Long lifespan

Compliance and Documentation

• DIN 13277 and IEC 61010-2-011 compliance
Liebherr laboratory and pharmaceutical refrigeration units meet all the features and performance criteria necessary for full compliance with DIN 13277. This standard defines requirements and test procedures for cooling and freezing equipment used in laboratories and for drug storage.
• Temperature distribution and consistency according to IEC 60068-3
• Safety according to IEC 61010-2-011
• Temperature setting (calibration)
• Logging of minimum/maximum temperature values
• Integrated connectivity (LAN or WiFi for BMS or SmartMonitoring systems)

Technical Data

• Gross/net volume: 642/480 L
• External dimensions (W/D/H) mm: 697/867/2135
• Internal dimensions (W/D/H) mm: 489/638/1470
• White, stainless steel exterior casing
• Door/Cover material: insulated glass
• Adjustable shelves: 4
• Shelf material: steel with plastic coating
• Usable shelf size (W/D) mm: 480 / 638
• Shelf load capacity: 60 kg
• Door opening direction: right, reversible
• Castors with arrestor at the front, fixed castors at the rear
• Gross/net weight: 169/152 kg
• Energy consumption/year: 317 kWh
• Ambient temperature: +10 °C to +35 °C
• Heat emission: 365 kJ/h
• Refrigerant: R 600a
• Noise level: 60 dB(A)
• Frequency/voltage: 50/60 Hz / 220-240 V~
%
Liebherr SRPvg 6511 heavy-duty fridge
Laboratory refrigerators and freezers are expected to provide the highest levels of safety and reliability. Precise electronic control, fan-assisted cooling, and highly efficient insulation result in outstanding energy efficiency, ensuring low operating costs and environmental protection. Advanced components and precise regulation ensure optimal storage of materials.

Product Features

Easy Operation
User-friendly solutions for daily use

• Built-in handle along the full height of the door
• Monochrome electronic control panel with 3 touch buttons
• Easy-to-clean stainless steel interior lining
• The door stays open at angles greater than 90°
• Flush-mounted interior ceiling LED lighting

Compliance and Documentation
Built-in safety features to protect sensitive materials

• Temperature setting (calibration)
• Logging of minimum/maximum temperature values
The recorded minimum and maximum internal temperatures are saved and can be easily read from the display.
• Connectivity available as an upgrade (LAN or WiFi for BMS or SmartMonitoring systems)
• Standard compliance: IEC 60068-3, IEC 61010-2-011

Safety and Reliability
Reliable storage thanks to consistent cooling performance, even in extreme ambient temperature conditions

• Temperature stability up to: ±3 °C (refrigerator) / ±5 °C (freezer)
• Alarm relay
Alarm transmission to the monitoring system ensures no deviations go unnoticed.
• The door automatically closes if opened at less than a 90° angle.
• Probe access opening: 10 mm in diameter
• Mechanical door lock
• Long lifespan

Technical Data

• Gross/net volume: 642/480 L
• External dimensions (W/D/H) mm: 697/867/2135
• Internal dimensions (W/D/H) mm: 489/638/1470
• Energy consumption/year: 286 kWh
• Ambient temperature: +10 °C to +35 °C
• Heat emission: 365 kJ/h
• Refrigerant: R 290
• Noise level: 60 dB(A)
• Frequency/voltage: 50 Hz / 220-240 V~
• Fan-assisted cooling system
• Automatic defrost
• Temperature range: 0 °C to +16 °C
• External casing/color: steel / white
• Interior lining: chrome-nickel steel (1.4301 / AISI 304)
• Door/Cover material: insulated glass
• Network connectivity via SmartModule, available as an upgrade
• WLAN/LAN connection: optional
• Adjustable shelves: 4
• Shelf material: steel with plastic coating
• Usable shelf size (W/D) mm: 480 / 638 mm
• Shelf load capacity: 60 kg
• Castors with arrestor at the front, fixed castors at the rear
• Probe access: 1 x Ø 12 mm
• Door opening direction: right, reversible
• Gross/net weight: 174/157 kg
%
Liebherr SRPvh 8401 heavy-duty fridge
Laboratory refrigerators and freezers are expected to provide the highest levels of safety and reliability. Precise electronic control, fan-assisted cooling, and highly efficient insulation result in outstanding energy efficiency, ensuring low operating costs and environmental protection. Advanced components and precise regulation ensure optimal storage of materials.

Product Features

• Fan-assisted cooling system
• Automatic defrost
• Temperature range: -2 °C to +16 °C

Easy Operation

• Built-in handle along the full height of the door
• 2.4” color electronic control panel with touch & swipe function
• Easy-to-clean stainless steel interior lining
• Flush-mounted interior lighting (vertical, full-height side LED lighting)

Safety and Reliability

• Temperature stability up to: ±3 °C
• VCC variable speed compressor
The variable-speed compressors always provide the appropriate performance. This results in reduced energy consumption and increased temperature stability.
• Warning signal in case of malfunction: optical and acoustic
• SafetyDevice: prevents the temperature from dropping below +2 °C to avoid freezing
• PT1000 product temperature sensor
In addition to the built-in control sensor, another temperature sensor is available for measuring the simulated product temperature. The value measured by the product temperature sensor can be displayed on the screen, calibrated, and used as the reference for the device's alarm function, ensuring safer storage based on real product temperature values.
• Power failure alarm
In case of a power outage, the built-in battery maintains power for at least twelve hours and immediately activates an audible and visual alarm. Additional indication of when the power outage started and the maximum temperature reached.
• LightAlarm
In case of uncontrolled temperature rise, a door left open, or another issue, the internal lighting of the device starts to flash.
• Alarm history: Easy quality control
Logging important data from the last 10 alarms (e.g., date or maximum temperature) for the final quality assessment of stored goods.
• Built-in data logger: Trackable for years
Complete traceability independent of monitoring systems with up to 5 years of logging for temperature profiles, alarm history, and service information. Stored data can be retrieved via the USB port.
• The door automatically closes if opened at less than a 90° angle.
• Probe access: 1 x Ø 12 mm
• Electronic locking system: Protects against unauthorized access with locking/unlocking via PIN code or remote control.
• SmartLock: Automatic door locking in case of temperature alarm, only accessible by authorized personnel.
• Long lifespan

Compliance and Documentation

• DIN 13277 and IEC 61010-2-011 compliance
Liebherr laboratory and pharmaceutical refrigeration units meet all the features and performance criteria necessary for full compliance with DIN 13277. This standard defines requirements and test procedures for cooling and freezing equipment used in laboratories and for drug storage.
• Temperature distribution and consistency according to IEC 60068-3
• Safety according to IEC 61010-2-011
• Temperature setting (calibration)
• Logging of minimum/maximum temperature values
• Integrated connectivity (LAN or WiFi for BMS or SmartMonitoring systems)

Technical Data

• Gross/net volume: 871/702 L
• External dimensions (W/D/H) mm: 787/1017/2135
• Internal dimensions (W/D/H) mm: 489/638/1470
• White, stainless steel exterior casing
• Door/Cover material: steel
• Adjustable shelves: 4
• Shelf material: steel with plastic coating
• Usable shelf size (W/D) mm: 570 / 788
• Shelf load capacity: 60 kg
• Door opening direction: right, reversible
• Castors with arrestor at the front, fixed castors at the rear
• Gross/net weight: 165/141 kg
• Energy consumption/year: 220 kWh
• Ambient temperature: +10 °C to +35 °C
• Heat emission: 360 kJ/h
• Refrigerant: R 600a
• Noise level: 60 dB(A)
• Frequency/voltage: 50/60 Hz / 220-240 V
%
Liebherr SRPvg 8401 heavy-duty fridge
Laboratory refrigerators and freezers are expected to provide the highest levels of safety and reliability. Precise electronic control, fan-assisted cooling, and highly efficient insulation result in outstanding energy efficiency, ensuring low operating costs and environmental protection. Advanced components and precise regulation ensure optimal storage of materials.

Product Features

Easy Operation
User-friendly solutions for daily use

• Built-in handle along the full height of the door
• Monochrome electronic control panel with 3 touch buttons
• Easy-to-clean stainless steel interior lining
• The door stays open at angles greater than 90°
• Flush-mounted interior ceiling LED lighting

Compliance and Documentation
Built-in safety features to protect sensitive materials

• Temperature setting (calibration)
• Logging of minimum/maximum temperature values
The recorded minimum and maximum internal temperatures are saved and can be easily read from the display.
• Connectivity available as an upgrade (LAN or WiFi for BMS or SmartMonitoring systems)
• Standard compliance: IEC 60068-3, IEC 61010-2-011

Safety and Reliability
Reliable storage thanks to consistent cooling performance, even in extreme ambient temperature conditions

• Temperature stability up to: ±3 °C (refrigerator) / ±5 °C (freezer)
• Alarm relay
Alarm transmission to the monitoring system ensures no deviations go unnoticed.
• The door automatically closes if opened at less than a 90° angle.
• Probe access opening: 10 mm in diameter
• Mechanical door lock
• Long lifespan

Technical Data

• Gross/net volume: 871/702 L
• External dimensions (W/D/H) mm: 787/1017/2135
• Internal dimensions (W/D/H) mm: 579/788/1470
• Energy consumption/year: 195 kWh
• Ambient temperature: +10 °C to +35 °C
• Heat emission: 350 kJ/h
• Refrigerant: R 290
• Noise level: 60 dB(A)
• Frequency/voltage: 50 Hz / 220-240 V~
• Fan-assisted cooling system
• Automatic defrost
• Temperature range: -2 °C to +16 °C
• External casing/color: steel / white
• Interior lining: chrome-nickel steel (1.4301 / AISI 304)
• Door/Cover material: steel
• Network connectivity via SmartModule, available as an upgrade
• WLAN/LAN connection: optional
• Adjustable shelves: 4
• Shelf material: steel with plastic coating
• Usable shelf size (W/D) mm: 480 / 638 mm
• Shelf load capacity: 60 kg
• Castors with arrestor at the front, fixed castors at the rear
• Probe access: 1 x Ø 12 mm
• Door opening direction: right, reversible
• Gross/net weight: 165/144 kg
%
Liebherr SRPvh 8411 heavy-duty fridge
Laboratory refrigerators and freezers are expected to provide the highest levels of safety and reliability. Precise electronic control, fan-assisted cooling, and highly efficient insulation result in outstanding energy efficiency, ensuring low operating costs and environmental protection. Advanced components and precise regulation ensure optimal storage of materials.

Product Features

• Fan-assisted cooling system
• Automatic defrost
• Temperature range: 0 °C to +16 °C

Easy Operation

• Built-in handle along the full height of the door
• 2.4” color electronic control panel with touch & swipe function
• Easy-to-clean stainless steel interior lining
• Flush-mounted interior lighting (vertical, full-height side LED lighting)

Safety and Reliability

• Temperature stability up to: ±3 °C
• VCC variable speed compressor
The variable-speed compressors always provide the appropriate performance. This results in reduced energy consumption and increased temperature stability.
• Warning signal in case of malfunction: optical and acoustic
• SafetyDevice: prevents the temperature from dropping below +2 °C to avoid freezing
• PT1000 product temperature sensor
In addition to the built-in control sensor, another temperature sensor is available for measuring the simulated product temperature. The value measured by the product temperature sensor can be displayed on the screen, calibrated, and used as the reference for the device's alarm function, ensuring safer storage based on real product temperature values.
• Power failure alarm
In case of a power outage, the built-in battery maintains power for at least twelve hours and immediately activates an audible and visual alarm. Additional indication of when the power outage started and the maximum temperature reached.
• LightAlarm
In case of uncontrolled temperature rise, a door left open, or another issue, the internal lighting of the device starts to flash.
• Alarm history: Easy quality control
Logging important data from the last 10 alarms (e.g., date or maximum temperature) for the final quality assessment of stored goods.
• Built-in data logger: Trackable for years
Complete traceability independent of monitoring systems with up to 5 years of logging for temperature profiles, alarm history, and service information. Stored data can be retrieved via the USB port.
• The door automatically closes if opened at less than a 90° angle.
• Probe access: 1 x Ø 12 mm
• Electronic locking system: Protects against unauthorized access with locking/unlocking via PIN code or remote control.
• SmartLock: Automatic door locking in case of temperature alarm, only accessible by authorized personnel.
• Long lifespan

Compliance and Documentation

• DIN 13277 and IEC 61010-2-011 compliance
Liebherr laboratory and pharmaceutical refrigeration units meet all the features and performance criteria necessary for full compliance with DIN 13277. This standard defines requirements and test procedures for cooling and freezing equipment used in laboratories and for drug storage.
• Temperature distribution and consistency according to IEC 60068-3
• Safety according to IEC 61010-2-011
• Temperature setting (calibration)
• Logging of minimum/maximum temperature values
• Integrated connectivity (LAN or WiFi for BMS or SmartMonitoring systems)

Technical Data
• Gross/net volume: 903/702 L
• External dimensions (W/D/H) mm: 787/1017/2135
• Internal dimensions (W/D/H) mm: 489/638/1470
• White, stainless steel exterior casing
• Door/Cover material: insulated glass
• Adjustable shelves: 4
• Shelf material: steel with plastic coating
• Usable shelf size (W/D) mm: 570 / 788
• Shelf load capacity: 60 kg
• Door opening direction: right, reversible
• Castors with arrestor at the front, fixed castors at the rear
• Gross/net weight: 165/147 kg
• Energy consumption/year: 220-374 kWh
• Ambient temperature: +10 °C to +35 °C
• Heat emission: 425 kJ/h
• Refrigerant: R 600a
• Noise level: 60 dB(A)
• Frequency/voltage: 50/60 Hz / 220-240 V~
%
Liebherr SRPvg 8411 heavy-duty fridge
Laboratory refrigerators and freezers are expected to provide the highest levels of safety and reliability. Precise electronic control, fan-assisted cooling, and highly efficient insulation result in outstanding energy efficiency, ensuring low operating costs and environmental protection. Advanced components and precise regulation ensure optimal storage of materials.

Product Features

Easy Operation
User-friendly solutions for daily use

• Built-in handle along the full height of the door
• Monochrome electronic control panel with 3 touch buttons
• Easy-to-clean stainless steel interior lining
• The door stays open at angles greater than 90°
• Flush-mounted interior ceiling LED lighting

Compliance and Documentation
Built-in safety features to protect sensitive materials

• Temperature setting (calibration)
• Logging of minimum/maximum temperature values
The recorded minimum and maximum internal temperatures are saved and can be easily read from the display.
• Connectivity available as an upgrade (LAN or WiFi for BMS or SmartMonitoring systems)
• Standard compliance: IEC 60068-3, IEC 61010-2-011

Safety and Reliability
Reliable storage thanks to consistent cooling performance, even in extreme ambient temperature conditions

• Temperature stability up to: ±3 °C (refrigerator) / ±5 °C (freezer)
• Alarm relay
Alarm transmission to the monitoring system ensures no deviations go unnoticed.
• The door automatically closes if opened at less than a 90° angle.
• Probe access opening: 10 mm in diameter
• Mechanical door lock
• Long lifespan

Technical Data

• Gross/net volume: 903/702 L
• External dimensions (W/D/H) mm: 787/1017/2135
• Internal dimensions (W/D/H) mm: 579/788/1470
• Energy consumption/year: 299 kWh
• Ambient temperature: +10 °C to +35 °C
• Heat emission: 400 kJ/h
• Refrigerant: R 290
• Noise level: 60 dB(A)
• Frequency/voltage: 50 Hz / 220-240 V~
• Fan-assisted cooling system
• Automatic defrost
• Temperature range: 0 °C to +16 °C
• External casing/color: steel / white
• Interior lining: chrome-nickel steel (1.4301 / AISI 304)
• Door/Cover material: insulated glass
• Network connectivity via SmartModule, available as an upgrade
• WLAN/LAN connection: optional
• Adjustable shelves: 4
• Shelf material: steel with plastic coating
• Usable shelf size (W/D) mm: 480 / 638 mm
• Shelf load capacity: 60 kg
• Castors with arrestor at the front, fixed castors at the rear
• Probe access: 1 x Ø 12 mm
• Door opening direction: right, reversible
• Gross/net weight: 186/168 kg
%
Liebherr SRPvh 1402 heavy-duty fridge
Laboratory refrigerators and freezers are expected to provide the highest levels of safety and reliability. Precise electronic control, fan-assisted cooling, and highly efficient insulation result in outstanding energy efficiency, ensuring low operating costs and environmental protection. Advanced components and precise regulation ensure optimal storage of materials.

Product Features

Easy Operation
User-friendly solutions for daily use

• Built-in handle along the full height of the door
• 2.4” color electronic control panel with touch & swipe function
• Easy-to-clean stainless steel interior lining
• Flush-mounted interior lighting (vertical, full-height side LED lighting)

Safety and Reliability

• Temperature stability up to: ±3 °C
• VCC variable speed compressor
The variable-speed compressors always provide the appropriate performance. This results in reduced energy consumption and increased temperature stability.
• Warning signal in case of malfunction: optical and acoustic
• SafetyDevice: prevents the temperature from dropping below +2 °C to avoid freezing
• PT1000 product temperature sensor
In addition to the built-in control sensor, another temperature sensor is available for measuring the simulated product temperature. The value measured by the product temperature sensor can be displayed on the screen, calibrated, and used as the reference for the device's alarm function, ensuring safer storage based on real product temperature values.
• Power failure alarm
In case of a power outage, the built-in battery maintains power for at least twelve hours and immediately activates an audible and visual alarm. Additional indication of when the power outage started and the maximum temperature reached.
• LightAlarm
In case of uncontrolled temperature rise, a door left open, or another issue, the internal lighting of the device starts to flash.
• Alarm history: Easy quality control
Logging important data from the last 10 alarms (e.g., date or maximum temperature) for the final quality assessment of stored goods.
• Built-in data logger: Trackable for years
Complete traceability independent of monitoring systems with up to 5 years of logging for temperature profiles, alarm history, and service information. Stored data can be retrieved via the USB port.
• The door automatically closes if opened at less than a 90° angle.
• Probe access: 1 x Ø 12 mm
• Electronic locking system: Protects against unauthorized access with locking/unlocking via PIN code or remote control.
• SmartLock: Automatic door locking in case of temperature alarm, only accessible by authorized personnel.
• Long lifespan

Compliance and Documentation

• DIN 13277 and IEC 61010-2-011 compliance
Liebherr laboratory and pharmaceutical refrigeration units meet all the features and performance criteria necessary for full compliance with DIN 13277. This standard defines requirements and test procedures for cooling and freezing equipment used in laboratories and for drug storage.
• Temperature distribution and consistency according to IEC 60068-3
• Safety according to IEC 61010-2-011
• Temperature setting (calibration)
• Logging of minimum/maximum temperature values
• Integrated connectivity (LAN or WiFi for BMS or SmartMonitoring systems)

Technical Data

• Gross/net volume: 1391/1091 L
• External dimensions (W/D/H) mm: 1427/867/2135
• Internal dimensions (W/D/H) mm: 489/638/1470
• White, stainless steel exterior casing
• Door/Cover material: steel
• Adjustable shelves: 12
• Shelf material: steel with plastic coating
• Usable shelf size (W/D) mm: 570 / 788
• Shelf load capacity: 60 kg
• Door opening direction: right fixed / left fixed
• Castors: 5 rotating castors, 2 with brakes
• Gross/net weight: 225/200 kg
• Energy consumption/year: 464 kWh
• Ambient temperature: +10 °C to +35 °C
• Heat emission: 565 kJ/h
• Refrigerant: R 600a
• Noise level: 60 dB(A)
• Frequency/voltage: 50/60 Hz / 220-240 V~
%
Liebherr SRPvg 1402 heavy-duty fridge
Laboratory refrigerators and freezers are expected to provide the highest levels of safety and reliability. Precise electronic control, fan-assisted cooling, and highly efficient insulation result in outstanding energy efficiency, ensuring low operating costs and environmental protection. Advanced components and precise regulation ensure optimal storage of materials.

Product Features

Easy Operation
User-friendly solutions for daily use

• Built-in handle along the full height of the door
• Monochrome electronic control panel with 3 touch buttons
• Easy-to-clean stainless steel interior lining
• The door stays open at angles greater than 90°
• Flush-mounted interior ceiling LED lighting

Compliance and Documentation
Built-in safety features to protect sensitive materials

• Temperature setting (calibration)
• Logging of minimum/maximum temperature values
The recorded minimum and maximum internal temperatures are saved and can be easily read from the display.
• Connectivity available as an upgrade (LAN or WiFi for BMS or SmartMonitoring systems)
• Standard compliance: IEC 60068-3, IEC 61010-2-011

Safety and Reliability
Reliable storage thanks to consistent cooling performance, even in extreme ambient temperature conditions

• Temperature stability up to: ±3 °C (refrigerator) / ±5 °C (freezer)
• Alarm relay
Alarm transmission to the monitoring system ensures no deviations go unnoticed.
• The door automatically closes if opened at less than a 90° angle.
• Probe access opening: 10 mm in diameter
• Mechanical door lock
• Long lifespan

Technical Data

• Gross/net volume: 1391/1091 L
• External dimensions (W/D/H) mm: 1427/867/2135
• Internal dimensions (W/D/H) mm: 1210/638/1470
• Energy consumption/year: 464 kWh
• Ambient temperature: +10 °C to +35 °C
• Heat emission: 520 kJ/h
• Refrigerant: R 290
• Noise level: 60 dB(A)
• Frequency/voltage: 50 Hz / 220-240 V~
• Fan-assisted cooling system
• Automatic defrost
• Temperature range: -2 °C to +16 °C
• External casing/color: steel / white
• Interior lining: chrome-nickel steel (1.4301 / AISI 304)
• Door/Cover material: steel
• Network connectivity via SmartModule, available as an upgrade
• WLAN/LAN connection: optional
• Adjustable shelves: 8
• Shelf material: steel with plastic coating
• Usable shelf size (W/D) mm: 480 / 638 mm
• Shelf load capacity: 60 kg
• Castors: 5 rotating castors, 2 with brakes
• Probe access: 1 x Ø 12 mm
• Door opening direction: left fixed / right fixed
• Gross/net weight: 225/200 kg
%
Liebherr SRPvh 1412 heavy-duty fridge
Laboratory refrigerators and freezers are expected to offer the highest safety and reliability to users. Precise electronic control, fan-assisted cooling, and highly efficient insulation work together to deliver outstanding energy efficiency, resulting in low operating costs and environmental protection. Advanced components and precise regulation ensure optimal storage of materials.

Product Features

• Fan-assisted cooling system
• Automatic defrost
• Temperature range: 0 °C to +16 °C

Easy Operation
User-friendly solutions for daily use

• Built-in handle along the full height of the door
• 2.4” color electronic control panel with touch & swipe functionality
• Easy-to-clean stainless steel interior lining
• Flush-mounted interior lighting (vertical, full-height side LED lighting)

Safety and Reliability

• Temperature stability up to: ±3 °C
• VCC variable speed compressor
The variable speed compressors ensure the appropriate level of performance is always available. This leads to reduced energy consumption and provides higher temperature stability.
• Visual and audible alarm system
• SafetyDevice: prevents the temperature from dropping below +2 °C, protecting against freezing
• PT1000 product temperature sensor
In addition to the built-in control sensor, a secondary temperature sensor is available to measure simulated product temperature. The value measured by the product temperature sensor is displayed and can be calibrated. The upper and lower threshold values for the device’s alarm function are based on this value, ensuring safer storage using real product temperature values.
• Power outage alarm
In the event of a power failure, the built-in battery maintains the power supply for at least 12 hours and triggers an immediate audible and visual alarm. Additional display indicates the time of the power outage and the highest temperature reached.
• LightAlarm
If the temperature rises unchecked, or if the door is left open or another issue occurs, the unit’s internal lighting will begin to flash.
• Alarm history: simple quality control
Logs important data from the last 10 alarms (such as date or maximum temperature) for easy final quality assessment of stored goods.
• Built-in data logger: traceability over several years
Complete traceability independent of monitoring systems by logging the temperature profile, alarm history, and service information for up to 5 years. The stored data can be retrieved via a USB port.
• The door automatically closes if opened at less than a 90° angle.
• Probe access opening: 1 x Ø 12 mm
• Electronic lock system: protection against unauthorized access with PIN code or remote lock/unlock.
• SmartLock: the door automatically locks in case of a temperature alarm and can only be unlocked by authorized personnel.
• Long lifespan

Compliance and Documentation

• DIN 13277 and IEC 61010-2-011 compliance
Liebherr laboratory and pharmaceutical refrigeration units meet all the characteristics and performance criteria required for full compliance with the DIN 13277 standard. This standard specifies the requirements and testing protocols for refrigeration and freezer units used in laboratories and for storing pharmaceuticals.
• Temperature distribution and stability according to IEC 60068-3
• Safety standards according to IEC 61010-2-011
• Temperature setting (calibration)
• Logging of minimum/maximum temperature values
• Integrated connectivity (LAN or WiFi for BMS or SmartMonitoring systems)

Technical Data

• Gross/net volume: 1447/1091 L
• External dimensions (W/D/H) mm: 1427/867/2135
• Internal dimensions (W/D/H) mm: 976/638/1470
• External casing/color: steel / white
• Door/Cover material: insulated glass
• Adjustable shelves: 8
• Shelf material: steel, plastic-coated
• Usable shelf size (W/D) mm: 570 / 788
• Shelf load capacity: 60 kg
• Door opening direction: right fixed / left fixed
• Castors: 5 rotating castors, 2 with brakes
• Gross/net weight: 288/263 kg
• Energy consumption/year: 705 kWh
• Ambient temperature: +10 °C to +35 °C
• Heat emission: 695 kJ/h
• Refrigerant: R 600a
• Noise level: 60 dB(A)
• Frequency/voltage: 50/60 Hz / 220-240 V~
%
Liebherr SRPvg 1412 heavy-duty fridge
Laboratory refrigerators and freezers are expected to offer the highest level of safety and reliability. The precise electronic control system, forced-air cooling, and highly efficient insulation combine to achieve outstanding energy efficiency, keeping operating costs low while ensuring environmental protection. Advanced components and precise regulation work together to ensure optimal storage conditions for materials over the long term.

Product Features

Simple Operation
User-friendly solutions for everyday use

• Built-in handle spanning the full height of the door
• Monochrome electronic control panel with 3 touch buttons
• Easy-to-clean stainless-steel interior
• The door remains open at an angle greater than 90°
• Flush-mounted internal ceiling LED lighting

Compliance and Documentation
Built-in safety features for the protection of sensitive materials:

• Temperature setting (calibration)
• Logging of minimum/maximum temperature values
The recorded minimum and maximum internal temperatures are saved by the unit and can be easily read on the display.
• Connectivity option for retrofitting (LAN or WiFi for BMS or SmartMonitoring system)
• Standards compliance: IEC 60068-3, IEC 61010-2-011

Safety and Reliability

Reliable storage due to consistent cooling performance, even under extreme environmental temperature conditions:
• Maximum temperature stability: ±3 °C for refrigerators / ±5 °C for freezers
• Alarm relay
Alarm transmission to the monitoring system to ensure no deviations are missed.
• The door automatically closes if opened at less than 90°.
• 10 mm diameter probe access port
• Mechanical door lock
• Long lifespan

Technical Data

• Gross/net capacity: 1447/1091 L
• External dimensions (W/D/H): 1427/867/2135 mm
• Internal dimensions (W/D/H): 1210/638/1470 mm
• Energy consumption/year: 464 kWh
• Ambient temperature: +10 °C to +35 °C
• Heat emission: 650 kJ/h
• Refrigerant: R 290
• Noise level: 60 dB(A)
• Frequency/voltage: 50 Hz / 220-240 V~
• Ventilated cooling system
• Automatic defrost
• Temperature range: 0 °C to +16 °C
• External cover/color: Steel / White
• Internal liner: Chrome-nickel steel (1.4301 / AISI 304)
• Door/Cover material: Insulated glass
• Connectivity type: SmartModule / retrofittable
• WLAN/LAN connection: Optional
• Number of adjustable shelves: 8
• Shelf material: Steel, plastic-coated
• Usable shelf size (W/D): 480/638 mm
• Shelf load capacity: 60 kg
• Castors with arrestor at the front, fixed castors at the rear
• Probe access: 1 x Ø 12 mm
• Door opening: Left fixed/right fixed
• Gross/net weight: 201/178 kg