Accessories for MIELE PLW 7111 SlimLine laboratory washer

%
Miele A 11/2 insert for the gentle cleaning of delicate load items by interrupting the water jet
Insert for the gentle cleaning of delicate load items by interrupting the water jet.
• With perforations 7 x 7 mm
• For use in upper and lower basket
%
Miele A 12/2 insert for the gentle cleaning of delicate load items by interrupting the water jet
Insert for the gentle cleaning of delicate load items by interrupting the water jet.
• With perforations 7 x 7 mm
• For use in upper and lower basket
%
Miele E 118 insert 1/1
For the optimum loading of half petri dishes.
• Suitable for 38 half petri dishes with Ø 100 mm
• Equipped with 38 holders, height 70 mm, distance approx. 26 mm
• For use in upper basket
%
Miele E 106 insert 1/2
• Area of application: reprocessing laboratory glassware and measuring cylinders
• Equipped with 10 spring hooks x 175 mm height & 16 x 105 mm height
• The distance between the spring hooks is approx. 60 mm
%
Miele A 300/2 module
For optimum loading of laboratory glassware – can be equipped with 8 nozzles.
• Area of application: reprocessing laboratory glassware
• Suitable for lab. glassware incl. Erlenmeyer and round flasks.
• Module w/o injector nozzles – equipped based on individual needs
• For up to 8 injector nozzles . Particularly suitable for nozzle diameters of 6 mm, e.g. A 840 or A 841, other diameters are possible depending on the application.
• Part of the EasyLoad system. The EasyLoad system makes reprocessing laboratory glassware considerably faster, simpler and more reliable. The biggest benefit afforded by the new system is that load items can be positioned over nozzles both more simply and faster as height adjustment of the holders is no longer necessary thanks to the smart combination of nozzles and holding frames. This makes correct positioning extremely easy.
• Nozzle spacing 118 mm across the width, 118 mm across the depth
%
Miele E 134 insert 1/2
For optimum loading of 210 slides.
• Area of application: reprocessing laboratory glassware
%
Miele AK 12/1 insert
For loading different utensils.
• Area of application: reprocessing laboratory glassware
• Suitable for beakers, funnels, breast milk pumps, for example
• With flexible handles
%
Miele A 303 module
For the optimum loading of up to 98 pipettes.
• Area of application: reprocessing pipettes/vials
• Suitable for 98 measuring and full pipettes, for example
• Height of holding frame 150 mm

It can be used in the lower basket A 150.
%
Miele A 300/3 module
For optimum loading of laboratory glassware – can be equipped with 8 nozzles.
• Area of application: reprocessing laboratory glassware
• Suitable for lab. glassware incl. Erlenmeyer and round flasks.
• Equipped with 4 A 840 nozzles and 4 A 841 nozzles
Size of A 840 injector nozzle: Ø 6 mm, height 130 mm
Size of A 841 injector nozzle: Ø 6 mm, height 210 mm
• Part of the EasyLoad system. The EasyLoad system makes reprocessing laboratory glassware considerably faster, simpler and more reliable. The biggest benefit afforded by the new system is that load items can be positioned over nozzles both more simply and faster as height adjustment of the holders is no longer necessary thanks to the smart combination of nozzles and holding frames. This makes correct positioning extremely easy.
• Nozzle spacing 118 mm across the width, 118 mm across the depth
%
Miele E 136 insert 1/1
For optimum loading of 56 half petri dishes.
• Area of application: reprocessing laboratory glassware
• Suitable for 56 half petri dishes with Ø 100 mm
• Equipped with 56 holders, height 70 mm, distance apart approx. 26 mm
• For use in lower basket
%
Miele E 106/2 insert 1/2
For the optimum loading of wide neck flasks, measuring cylinders, etc.
• Area of application: reprocessing laboratory glassware
• Equipped with 13 large spring hooks x 175 mm height
• The distance between the spring hooks is approx. 85 mm
%
Miele E 103/1 insert 1/4
• Area of application: reprocessing laboratory glassware
• Suitable for about 200 Test tubes (up to 12 x 75 mm)
• Divided into 6 surfaces
• The mesh width is 8 x 8 mm
• Including lid A 13
%
Miele A 301/4 module
For optimum loading of laboratory glassware – can be equipped with 18 nozzles.
• Area of application: reprocessing laboratory glassware
• Suitable for lab. glassware incl. Erlenmeyer and round flasks.
• Module w/o injector nozzles – equipped based on individual needs
• For up to 18 injector nozzles. (Particularly suitable for nozzle diameters of 4 mm, e.g. A 842 or A 843; other diameters are possible depending on the application.)
• Part of the EasyLoad system. The EasyLoad system makes reprocessing laboratory glassware considerably faster, simpler and more reliable. The biggest benefit afforded by the new system is that load items can be positioned over nozzles both more simply and faster as height adjustment of the holders is no longer necessary thanks to the smart combination of nozzles and holding frames. This makes correct positioning extremely easy.
• Nozzle spacing 157 mm across the width, 78 mm across the depth
%
Miele E 137 insert 1/1
For optimum loading of 56 half petri dishes.
• Area of application: reprocessing laboratory glassware
• Suitable for 56 half petri dishes with Ø 100 mm
• Equipped with 56 holders, height 70 mm, distance apart approx. 26 mm
• For use in lower basket
%
Miele E 109 insert 1/2
For the optimum loading of beakers up to 250 ml.
• Area of application: reprocessing laboratory glassware
• Suitable for 21 glass beakers up to 250 ml
• Equipped with 21 x 3 stay bars
• For use in upper and lower basket
%
Miele E 104/1 insert 1/4
• Area of application: reprocessing laboratory glassware
• Suitable for about 200 Test tubes (up to 12 x 105 mm)
• Capacity including lid A 13
• The mesh width is 8 x 8 mm
• External dimensions: H: 132 (152), W: 200, D: 320 mm
%
Miele A 301/5 module
For optimum loading of laboratory glassware – can be equipped with 18 nozzles.
• Area of application: reprocessing laboratory glassware
• Suitable for lab. glassware incl. Erlenmeyer and round flasks.
• Equipped with 9 A 842 nozzles and 9 A 843 nozzles
Size of A 842 injector nozzle: Ø 4 mm, height 90 mm
Size of A 843 injector nozzle: Ø 4 mm, height 185 mm
• Part of the EasyLoad system. The EasyLoad system makes reprocessing laboratory glassware considerably faster, simpler and more reliable. The biggest benefit afforded by the new system is that load items can be positioned over nozzles both more simply and faster as height adjustment of the holders is no longer necessary thanks to the smart combination of nozzles and holding frames. This makes correct positioning extremely easy.
• Nozzle spacing 78 mm across the width, 157 mm across the depth
%
Miele E 402 insert
For optimum loading of up to 44 watch glasses.
• Area of application: reprocessing laboratory glassware
• Suitable for 44 watch glasses Ø 80 - 125 mm
• Equipped with 23 bars spaced 15 mm apart
%
Miele E 110 insert 1/2
For the optimum loading of beakers from 250 to 600 ml.
• Area of application: reprocessing laboratory glassware
• Suitable for 10 glass beakers between 250 - 600 ml
• Equipped with 10 x 3 stay bars
• For use in lower basket
%
Miele E 105/1 insert 1/4
• Area of application: reprocessing laboratory glassware
• Suitable for about 200 Test tubes (up to 12 x 165 mm)
• Capacity including lid A 13
• The mesh width is 9 x 9 mm