Laboratory refrigerator and freezer

Filters by category

%
UUS-480B-1-5D-SS ESCO Lexicon® II Ultra-low Temperature Freezer
Ultra-Low Temperature (ULT) Freezers are widely used in scientific research for long-term storage of samples. As ULT freezers are often operated at -80°C continuously for years, reliability is of paramount importance to the researchers.
Constructed from high-quality proven components with energy-efficient refrigeration design, Esco Lexicon® II ULT freezers provide top notch protection that can withstand the test of time to guarantee the integrity of your samples. Superior performance, lower energy costs, better protection.
Features
• Gold Controller
Simple, intuitive operation
Large display of actual temperature with a simultaneous display of set temperature and ambient temperature
USB interface allows transfer of temperature data and the last 20 system events
Advanced input voltage Buck/Boost transformer protects critical freezer components.Additional sample protection!!
• Fast Pull Down
Pull down time is the time required to bring down the temperature of the ULT freezer from ambient to the set temperature.
Esco Lexicon® II has a short pull down time which signifies an efficient refrigeration system
• Fast Temperature Recovery after door opening
Esco Lexicon® II recovers temperature in minutes following a 1 minute door opening.
Fast recovery in temperature ensures integrity of stored samples.
• Excellent Uniformity
Uniformity test measures the difference between the coldest spot and warmest spot in the freezer chamber when the freezer is operating at set temperature.
Esco Lexicon® II has excellent uniformity under normal operating conditions.
This guarantees that all samples are at the correct temperature.
• Extended warm-up Time during a power failure
Warm-up time measures the time taken for temperature to rise up (from -80°C to -50°C) when the power is interrupted
With a robust insulation system in place, Esco Lexicon® II has the best warm-up time among the freezers compared on the right*. Slower warm-up during an extended power failure buys the user time for carrying out a back-up plan.
• Other Features
Sample port
Excellent triple gasket door seals
3 or 5 individual inner doors
Modern refrigeration system
Pressure equalization port
Isocide™ powder coat
Quickopen™ fast door re-open system
%
UUS-363B-1-5D-SS ESCO Lexicon® II Ultra-low Temperature Freezer
Ultra-Low Temperature (ULT) Freezers are widely used in scientific research for long-term storage of samples. As ULT freezers are often operated at -80°C continuously for years, reliability is of paramount importance to the researchers.
Constructed from high-quality proven components with energy-efficient refrigeration design, Esco Lexicon® II ULT freezers provide top notch protection that can withstand the test of time to guarantee the integrity of your samples. Superior performance, lower energy costs, better protection.
Features
• Gold Controller
Simple, intuitive operation
Large display of actual temperature with a simultaneous display of set temperature and ambient temperature
USB interface allows transfer of temperature data and the last 20 system events
Advanced input voltage Buck/Boost transformer protects critical freezer components.Additional sample protection!!
• Fast Pull Down
Pull down time is the time required to bring down the temperature of the ULT freezer from ambient to the set temperature.
Esco Lexicon® II has a short pull down time which signifies an efficient refrigeration system
• Fast Temperature Recovery after door opening
Esco Lexicon® II recovers temperature in minutes following a 1 minute door opening.
Fast recovery in temperature ensures integrity of stored samples.
• Excellent Uniformity
Uniformity test measures the difference between the coldest spot and warmest spot in the freezer chamber when the freezer is operating at set temperature.
Esco Lexicon® II has excellent uniformity under normal operating conditions.
This guarantees that all samples are at the correct temperature.
• Extended warm-up Time during a power failure
Warm-up time measures the time taken for temperature to rise up (from -80°C to -50°C) when the power is interrupted
With a robust insulation system in place, Esco Lexicon® II has the best warm-up time among the freezers compared on the right*. Slower warm-up during an extended power failure buys the user time for carrying out a back-up plan.
• Other Features
Sample port
Excellent triple gasket door seals
3 or 5 individual inner doors
Modern refrigeration system
Pressure equalization port
Isocide™ powder coat
Quickopen™ fast door re-open system
%
UUS-714B-1-SS ESCO Lexicon® II Ultra-low Temperature Freezer
Ultra-Low Temperature (ULT) Freezers are widely used in scientific research for long-term storage of samples. As ULT freezers are often operated at -80°C continuously for years, reliability is of paramount importance to the researchers.
Constructed from high-quality proven components with energy-efficient refrigeration design, Esco Lexicon® II ULT freezers provide top notch protection that can withstand the test of time to guarantee the integrity of your samples. Superior performance, lower energy costs, better protection.
Features
• Gold Controller
Simple, intuitive operation
Large display of actual temperature with a simultaneous display of set temperature and ambient temperature
USB interface allows transfer of temperature data and the last 20 system events
Advanced input voltage Buck/Boost transformer protects critical freezer components.Additional sample protection!!
• Fast Pull Down
Pull down time is the time required to bring down the temperature of the ULT freezer from ambient to the set temperature.
Esco Lexicon® II has a short pull down time which signifies an efficient refrigeration system
• Fast Temperature Recovery after door opening
Esco Lexicon® II recovers temperature in minutes following a 1 minute door opening.
Fast recovery in temperature ensures integrity of stored samples.
• Excellent Uniformity
Uniformity test measures the difference between the coldest spot and warmest spot in the freezer chamber when the freezer is operating at set temperature.
Esco Lexicon® II has excellent uniformity under normal operating conditions.
This guarantees that all samples are at the correct temperature.
• Extended warm-up Time during a power failure
Warm-up time measures the time taken for temperature to rise up (from -80°C to -50°C) when the power is interrupted
With a robust insulation system in place, Esco Lexicon® II has the best warm-up time among the freezers compared on the right*. Slower warm-up during an extended power failure buys the user time for carrying out a back-up plan.
• Other Features
Sample port
Excellent triple gasket door seals
3 or 5 individual inner doors
Modern refrigeration system
Pressure equalization port
Isocide™ powder coat
Quickopen™ fast door re-open system
%
UUS-597B-1-SS ESCO Lexicon® II Ultra-low Temperature Freezer
Ultra-Low Temperature (ULT) Freezers are widely used in scientific research for long-term storage of samples. As ULT freezers are often operated at -80°C continuously for years, reliability is of paramount importance to the researchers.
Constructed from high-quality proven components with energy-efficient refrigeration design, Esco Lexicon® II ULT freezers provide top notch protection that can withstand the test of time to guarantee the integrity of your samples. Superior performance, lower energy costs, better protection.
Features
• Gold Controller
Simple, intuitive operation
Large display of actual temperature with a simultaneous display of set temperature and ambient temperature
USB interface allows transfer of temperature data and the last 20 system events
Advanced input voltage Buck/Boost transformer protects critical freezer components.Additional sample protection!!
• Fast Pull Down
Pull down time is the time required to bring down the temperature of the ULT freezer from ambient to the set temperature.
Esco Lexicon® II has a short pull down time which signifies an efficient refrigeration system
• Fast Temperature Recovery after door opening
Esco Lexicon® II recovers temperature in minutes following a 1 minute door opening.
Fast recovery in temperature ensures integrity of stored samples.
• Excellent Uniformity
Uniformity test measures the difference between the coldest spot and warmest spot in the freezer chamber when the freezer is operating at set temperature.
Esco Lexicon® II has excellent uniformity under normal operating conditions.
This guarantees that all samples are at the correct temperature.
• Extended warm-up Time during a power failure
Warm-up time measures the time taken for temperature to rise up (from -80°C to -50°C) when the power is interrupted
With a robust insulation system in place, Esco Lexicon® II has the best warm-up time among the freezers compared on the right*. Slower warm-up during an extended power failure buys the user time for carrying out a back-up plan.
• Other Features
Sample port
Excellent triple gasket door seals
3 or 5 individual inner doors
Modern refrigeration system
Pressure equalization port
Isocide™ powder coat
Quickopen™ fast door re-open system
%
UUS-480B-1-SS ESCO Lexicon® II Ultra-low Temperature Freezer
Ultra-Low Temperature (ULT) Freezers are widely used in scientific research for long-term storage of samples. As ULT freezers are often operated at -80°C continuously for years, reliability is of paramount importance to the researchers.
Constructed from high-quality proven components with energy-efficient refrigeration design, Esco Lexicon® II ULT freezers provide top notch protection that can withstand the test of time to guarantee the integrity of your samples. Superior performance, lower energy costs, better protection.
Features
• Gold Controller
Simple, intuitive operation
Large display of actual temperature with a simultaneous display of set temperature and ambient temperature
USB interface allows transfer of temperature data and the last 20 system events
Advanced input voltage Buck/Boost transformer protects critical freezer components.Additional sample protection!!
• Fast Pull Down
Pull down time is the time required to bring down the temperature of the ULT freezer from ambient to the set temperature.
Esco Lexicon® II has a short pull down time which signifies an efficient refrigeration system
• Fast Temperature Recovery after door opening
Esco Lexicon® II recovers temperature in minutes following a 1 minute door opening.
Fast recovery in temperature ensures integrity of stored samples.
• Excellent Uniformity
Uniformity test measures the difference between the coldest spot and warmest spot in the freezer chamber when the freezer is operating at set temperature.
Esco Lexicon® II has excellent uniformity under normal operating conditions.
This guarantees that all samples are at the correct temperature.
• Extended warm-up Time during a power failure
Warm-up time measures the time taken for temperature to rise up (from -80°C to -50°C) when the power is interrupted
With a robust insulation system in place, Esco Lexicon® II has the best warm-up time among the freezers compared on the right*. Slower warm-up during an extended power failure buys the user time for carrying out a back-up plan.
• Other Features
Sample port
Excellent triple gasket door seals
3 or 5 individual inner doors
Modern refrigeration system
Pressure equalization port
Isocide™ powder coat
Quickopen™ fast door re-open system
%
UUS-363B-1-SS ESCO Lexicon® II Ultra-low Temperature Freezer
Ultra-Low Temperature (ULT) Freezers are widely used in scientific research for long-term storage of samples. As ULT freezers are often operated at -80°C continuously for years, reliability is of paramount importance to the researchers.
Constructed from high-quality proven components with energy-efficient refrigeration design, Esco Lexicon® II ULT freezers provide top notch protection that can withstand the test of time to guarantee the integrity of your samples. Superior performance, lower energy costs, better protection.
Features
• Gold Controller
Simple, intuitive operation
Large display of actual temperature with a simultaneous display of set temperature and ambient temperature
USB interface allows transfer of temperature data and the last 20 system events
Advanced input voltage Buck/Boost transformer protects critical freezer components.Additional sample protection!!
• Fast Pull Down
Pull down time is the time required to bring down the temperature of the ULT freezer from ambient to the set temperature.
Esco Lexicon® II has a short pull down time which signifies an efficient refrigeration system
• Fast Temperature Recovery after door opening
Esco Lexicon® II recovers temperature in minutes following a 1 minute door opening.
Fast recovery in temperature ensures integrity of stored samples.
• Excellent Uniformity
Uniformity test measures the difference between the coldest spot and warmest spot in the freezer chamber when the freezer is operating at set temperature.
Esco Lexicon® II has excellent uniformity under normal operating conditions.
This guarantees that all samples are at the correct temperature.
• Extended warm-up Time during a power failure
Warm-up time measures the time taken for temperature to rise up (from -80°C to -50°C) when the power is interrupted
With a robust insulation system in place, Esco Lexicon® II has the best warm-up time among the freezers compared on the right*. Slower warm-up during an extended power failure buys the user time for carrying out a back-up plan.
• Other Features
Sample port
Excellent triple gasket door seals
3 or 5 individual inner doors
Modern refrigeration system
Pressure equalization port
Isocide™ powder coat
Quickopen™ fast door re-open system
%
UUS-714A-1-5D-SS ESCO Lexicon® II Ultra-low Temperature Freezer
Ultra-Low Temperature (ULT) Freezers are widely used in scientific research for long-term storage of samples. As ULT freezers are often operated at -80°C continuously for years, reliability is of paramount importance to the researchers.
Constructed from high-quality proven components with energy-efficient refrigeration design, Esco Lexicon® II ULT freezers provide top notch protection that can withstand the test of time to guarantee the integrity of your samples. Superior performance, lower energy costs, better protection.
Features
Silver Controller
• Simple, intuitive operation
• Large display of actual temperature
• Clear indication of alarms
Fast Pull Down
• Pull down time is the time required to bring down the temperature of the ULT freezer from ambient to the set temperature.
• Esco Lexicon® II has a short pull down time which signifies an efficient refrigeration system
Fast Temperature Recovery after door opening
• Esco Lexicon® II recovers temperature in minutes following a 1 minute door opening.
• Fast recovery in temperature ensures integrity of stored samples.
Excellent Uniformity
• Uniformity test measures the difference between the coldest spot and warmest spot in the freezer chamber when the freezer is operating at set temperature.
• Esco Lexicon® II has excellent uniformity under normal operating conditions.
• This guarantees that all samples are at the correct temperature.
Extended warm-up Time during a power failure
• Warm-up time measures the time taken for temperature to rise up (from -80°C to -50°C) when the power is interrupted
• With a robust insulation system in place, Esco Lexicon® II has the best warm-up time among the freezers compared on the right*. Slower warm-up during an extended power failure buys the user time for carrying out a back-up plan.
Other Features
• Sample port
• Excellent triple gasket door seals
• 3 or 5 individual inner doors
• Modern refrigeration system
• Pressure equalization port
• Isocide™ powder coat
• Quickopen™ fast door re-open system
%
UUS-597A-1-5D-SS ESCO Lexicon® II Ultra-low Temperature Freezer
Ultra-Low Temperature (ULT) Freezers are widely used in scientific research for long-term storage of samples. As ULT freezers are often operated at -80°C continuously for years, reliability is of paramount importance to the researchers.
Constructed from high-quality proven components with energy-efficient refrigeration design, Esco Lexicon® II ULT freezers provide top notch protection that can withstand the test of time to guarantee the integrity of your samples. Superior performance, lower energy costs, better protection.
Features
Silver Controller
• Simple, intuitive operation
• Large display of actual temperature
• Clear indication of alarms
Fast Pull Down
• Pull down time is the time required to bring down the temperature of the ULT freezer from ambient to the set temperature.
• Esco Lexicon® II has a short pull down time which signifies an efficient refrigeration system
Fast Temperature Recovery after door opening
• Esco Lexicon® II recovers temperature in minutes following a 1 minute door opening.
• Fast recovery in temperature ensures integrity of stored samples.
Excellent Uniformity
• Uniformity test measures the difference between the coldest spot and warmest spot in the freezer chamber when the freezer is operating at set temperature.
• Esco Lexicon® II has excellent uniformity under normal operating conditions.
• This guarantees that all samples are at the correct temperature.
Extended warm-up Time during a power failure
• Warm-up time measures the time taken for temperature to rise up (from -80°C to -50°C) when the power is interrupted
• With a robust insulation system in place, Esco Lexicon® II has the best warm-up time among the freezers compared on the right*. Slower warm-up during an extended power failure buys the user time for carrying out a back-up plan.
Other Features
• Sample port
• Excellent triple gasket door seals
• 3 or 5 individual inner doors
• Modern refrigeration system
• Pressure equalization port
• Isocide™ powder coat
• Quickopen™ fast door re-open system
%
UUS-480A-1-5D-SS ESCO Lexicon® II Ultra-low Temperature Freezer
Ultra-Low Temperature (ULT) Freezers are widely used in scientific research for long-term storage of samples. As ULT freezers are often operated at -80°C continuously for years, reliability is of paramount importance to the researchers.
Constructed from high-quality proven components with energy-efficient refrigeration design, Esco Lexicon® II ULT freezers provide top notch protection that can withstand the test of time to guarantee the integrity of your samples. Superior performance, lower energy costs, better protection.
Features
Silver Controller
• Simple, intuitive operation
• Large display of actual temperature
• Clear indication of alarms
Fast Pull Down
• Pull down time is the time required to bring down the temperature of the ULT freezer from ambient to the set temperature.
• Esco Lexicon® II has a short pull down time which signifies an efficient refrigeration system
Fast Temperature Recovery after door opening
• Esco Lexicon® II recovers temperature in minutes following a 1 minute door opening.
• Fast recovery in temperature ensures integrity of stored samples.
Excellent Uniformity
• Uniformity test measures the difference between the coldest spot and warmest spot in the freezer chamber when the freezer is operating at set temperature.
• Esco Lexicon® II has excellent uniformity under normal operating conditions.
• This guarantees that all samples are at the correct temperature.
Extended warm-up Time during a power failure
• Warm-up time measures the time taken for temperature to rise up (from -80°C to -50°C) when the power is interrupted
• With a robust insulation system in place, Esco Lexicon® II has the best warm-up time among the freezers compared on the right*. Slower warm-up during an extended power failure buys the user time for carrying out a back-up plan.
Other Features
• Sample port
• Excellent triple gasket door seals
• 3 or 5 individual inner doors
• Modern refrigeration system
• Pressure equalization port
• Isocide™ powder coat
• Quickopen™ fast door re-open system
%
UUS-363A-1-5D-SS ESCO Lexicon® II Ultra-low Temperature Freezer
Ultra-Low Temperature (ULT) Freezers are widely used in scientific research for long-term storage of samples. As ULT freezers are often operated at -80°C continuously for years, reliability is of paramount importance to the researchers.
Constructed from high-quality proven components with energy-efficient refrigeration design, Esco Lexicon® II ULT freezers provide top notch protection that can withstand the test of time to guarantee the integrity of your samples. Superior performance, lower energy costs, better protection.
Features
Silver Controller
• Simple, intuitive operation
• Large display of actual temperature
• Clear indication of alarms
Fast Pull Down
• Pull down time is the time required to bring down the temperature of the ULT freezer from ambient to the set temperature.
• Esco Lexicon® II has a short pull down time which signifies an efficient refrigeration system
Fast Temperature Recovery after door opening
• Esco Lexicon® II recovers temperature in minutes following a 1 minute door opening.
• Fast recovery in temperature ensures integrity of stored samples.
Excellent Uniformity
• Uniformity test measures the difference between the coldest spot and warmest spot in the freezer chamber when the freezer is operating at set temperature.
• Esco Lexicon® II has excellent uniformity under normal operating conditions.
• This guarantees that all samples are at the correct temperature.
Extended warm-up Time during a power failure
• Warm-up time measures the time taken for temperature to rise up (from -80°C to -50°C) when the power is interrupted
• With a robust insulation system in place, Esco Lexicon® II has the best warm-up time among the freezers compared on the right*. Slower warm-up during an extended power failure buys the user time for carrying out a back-up plan.
Other Features
• Sample port
• Excellent triple gasket door seals
• 3 or 5 individual inner doors
• Modern refrigeration system
• Pressure equalization port
• Isocide™ powder coat
• Quickopen™ fast door re-open system
%
UUS-714A-1-SS ESCO Lexicon® II Ultra-low Temperature Freezer
Ultra-Low Temperature (ULT) Freezers are widely used in scientific research for long-term storage of samples. As ULT freezers are often operated at -80°C continuously for years, reliability is of paramount importance to the researchers.
Constructed from high-quality proven components with energy-efficient refrigeration design, Esco Lexicon® II ULT freezers provide top notch protection that can withstand the test of time to guarantee the integrity of your samples. Superior performance, lower energy costs, better protection.
Features
Silver Controller
• Simple, intuitive operation
• Large display of actual temperature
• Clear indication of alarms
Fast Pull Down
• Pull down time is the time required to bring down the temperature of the ULT freezer from ambient to the set temperature.
• Esco Lexicon® II has a short pull down time which signifies an efficient refrigeration system
Fast Temperature Recovery after door opening
• Esco Lexicon® II recovers temperature in minutes following a 1 minute door opening.
• Fast recovery in temperature ensures integrity of stored samples.
Excellent Uniformity
• Uniformity test measures the difference between the coldest spot and warmest spot in the freezer chamber when the freezer is operating at set temperature.
• Esco Lexicon® II has excellent uniformity under normal operating conditions.
• This guarantees that all samples are at the correct temperature.
Extended warm-up Time during a power failure
• Warm-up time measures the time taken for temperature to rise up (from -80°C to -50°C) when the power is interrupted
• With a robust insulation system in place, Esco Lexicon® II has the best warm-up time among the freezers compared on the right*. Slower warm-up during an extended power failure buys the user time for carrying out a back-up plan.
Other Features
• Sample port
• Excellent triple gasket door seals
• 3 or 5 individual inner doors
• Modern refrigeration system
• Pressure equalization port
• Isocide™ powder coat
• Quickopen™ fast door re-open system
%
UUS-597A-1-SS ESCO Lexicon® II Ultra-low Temperature Freezer
Ultra-Low Temperature (ULT) Freezers are widely used in scientific research for long-term storage of samples. As ULT freezers are often operated at -80°C continuously for years, reliability is of paramount importance to the researchers.
Constructed from high-quality proven components with energy-efficient refrigeration design, Esco Lexicon® II ULT freezers provide top notch protection that can withstand the test of time to guarantee the integrity of your samples. Superior performance, lower energy costs, better protection.
Features
Silver Controller
• Simple, intuitive operation
• Large display of actual temperature
• Clear indication of alarms
Fast Pull Down
• Pull down time is the time required to bring down the temperature of the ULT freezer from ambient to the set temperature.
• Esco Lexicon® II has a short pull down time which signifies an efficient refrigeration system
Fast Temperature Recovery after door opening
• Esco Lexicon® II recovers temperature in minutes following a 1 minute door opening.
• Fast recovery in temperature ensures integrity of stored samples.
Excellent Uniformity
• Uniformity test measures the difference between the coldest spot and warmest spot in the freezer chamber when the freezer is operating at set temperature.
• Esco Lexicon® II has excellent uniformity under normal operating conditions.
• This guarantees that all samples are at the correct temperature.
Extended warm-up Time during a power failure
• Warm-up time measures the time taken for temperature to rise up (from -80°C to -50°C) when the power is interrupted
• With a robust insulation system in place, Esco Lexicon® II has the best warm-up time among the freezers compared on the right*. Slower warm-up during an extended power failure buys the user time for carrying out a back-up plan.
Other Features
• Sample port
• Excellent triple gasket door seals
• 3 or 5 individual inner doors
• Modern refrigeration system
• Pressure equalization port
• Isocide™ powder coat
• Quickopen™ fast door re-open system
%
UUS-480A-1-SS ESCO Lexicon® II Ultra-low Temperature Freezer
Ultra-Low Temperature (ULT) Freezers are widely used in scientific research for long-term storage of samples. As ULT freezers are often operated at -80°C continuously for years, reliability is of paramount importance to the researchers.
Constructed from high-quality proven components with energy-efficient refrigeration design, Esco Lexicon® II ULT freezers provide top notch protection that can withstand the test of time to guarantee the integrity of your samples. Superior performance, lower energy costs, better protection.
Features
Silver Controller
• Simple, intuitive operation
• Large display of actual temperature
• Clear indication of alarms
Fast Pull Down
• Pull down time is the time required to bring down the temperature of the ULT freezer from ambient to the set temperature.
• Esco Lexicon® II has a short pull down time which signifies an efficient refrigeration system
Fast Temperature Recovery after door opening
• Esco Lexicon® II recovers temperature in minutes following a 1 minute door opening.
• Fast recovery in temperature ensures integrity of stored samples.
Excellent Uniformity
• Uniformity test measures the difference between the coldest spot and warmest spot in the freezer chamber when the freezer is operating at set temperature.
• Esco Lexicon® II has excellent uniformity under normal operating conditions.
• This guarantees that all samples are at the correct temperature.
Extended warm-up Time during a power failure
• Warm-up time measures the time taken for temperature to rise up (from -80°C to -50°C) when the power is interrupted
• With a robust insulation system in place, Esco Lexicon® II has the best warm-up time among the freezers compared on the right*. Slower warm-up during an extended power failure buys the user time for carrying out a back-up plan.
Other Features
• Sample port
• Excellent triple gasket door seals
• 3 or 5 individual inner doors
• Modern refrigeration system
• Pressure equalization port
• Isocide™ powder coat
• Quickopen™ fast door re-open system
%
UUS-363A-1-SS ESCO Lexicon® II Ultra-low Temperature Freezer
Ultra-Low Temperature (ULT) Freezers are widely used in scientific research for long-term storage of samples. As ULT freezers are often operated at -80°C continuously for years, reliability is of paramount importance to the researchers.
Constructed from high-quality proven components with energy-efficient refrigeration design, Esco Lexicon® II ULT freezers provide top notch protection that can withstand the test of time to guarantee the integrity of your samples. Superior performance, lower energy costs, better protection.
Features
Silver Controller
• Simple, intuitive operation
• Large display of actual temperature
• Clear indication of alarms
Fast Pull Down
• Pull down time is the time required to bring down the temperature of the ULT freezer from ambient to the set temperature.
• Esco Lexicon® II has a short pull down time which signifies an efficient refrigeration system
Fast Temperature Recovery after door opening
• Esco Lexicon® II recovers temperature in minutes following a 1 minute door opening.
• Fast recovery in temperature ensures integrity of stored samples.
Excellent Uniformity
• Uniformity test measures the difference between the coldest spot and warmest spot in the freezer chamber when the freezer is operating at set temperature.
• Esco Lexicon® II has excellent uniformity under normal operating conditions.
• This guarantees that all samples are at the correct temperature.
Extended warm-up Time during a power failure
• Warm-up time measures the time taken for temperature to rise up (from -80°C to -50°C) when the power is interrupted
• With a robust insulation system in place, Esco Lexicon® II has the best warm-up time among the freezers compared on the right*. Slower warm-up during an extended power failure buys the user time for carrying out a back-up plan.
Other Features
• Sample port
• Excellent triple gasket door seals
• 3 or 5 individual inner doors
• Modern refrigeration system
• Pressure equalization port
• Isocide™ powder coat
• Quickopen™ fast door re-open system
%
KIRSCH FROSTER LABO 730 PRO-ACTIVE laboratory freezer
Safe and worry-free storage of your laboratory samples at -30 °C. Guaranteed by the KIRSCH Airflow-Concept, automatic defrosting and much more. GMP compliant, ensures a constant interior temperature even during defrosting.

KIRSCH-Airflow-Concept
• The world's smallest temperature deviations from the warmest to the coldest storage location thanks to PRO-ACTIVE control & KIRSCH-Airflow-Concept (ΔT= 2,5°C)
• PRO-ACTIVE control: permanent, proactive monitoring of performance data and alarms in the event of deviations (more information)
• Precise temperature control thanks to two PT-1000 temperature sensors
• Re-circulation air-cooling
• Rapid freezing funtion

Ergonomics-Concept
• Automatic defrosting and melt walter evaporation
• Door heating
• Ergonomics door opener
• Flexible interior fittings
• 5 shelves, height adjustable
• Castors

Safety and Digital Documentation
• Optical and acoustic alarm signal even in the event of a power failureMinimum / maximum temperature memory
• LED temperature display for easy readabilit
• Potential-free contact for connection to remote warning systems
• Data documentation can be read out as standard via USB interface using a USB stick and KIRSCH-DATANET software
• Lockable door

Options
• Modification for operation in the clean room
• Adjustable feet to compensate for uneven floors
• Additional wire shelves on mountings or support rails
• Drawers with support rails: 57 x 43 x 5.6 (w x d x h in cm)
• Aluminium trays , 60 x 40 x 2.5 (w x d x h in cm)
• Baskets with support rails: 60 x 45 x10 cm, 60 x 45 x 10 (w x d x h in cm)
• Water-cooled refrigerating machine
• GSM module
• Outer housing made of chrome-nickel steel 4301, longitudinally brushed
• PC-KIT-NET (network-compatible version)
• Pen-recording thermometer for placing loosely inside appliance with waxed paper strips
• Incorporated disc type pen-thermometer, 7-day recording time with recording discs (100 pack) and 5 felt tip pens
• Temperature sensor PT 100 or PT 1000 including built-in reference body (measurement bottle or refrigerating block)

Technical Specifications
• Temperature setting (approx.): -10 to -25 °C
• Voltage: 220 - 240 V
• Frequency: 50 / 60 Hz
• Power consumption: 230 Watts
• Average consumption: 4.58 KWh / 24 h
• Overall dimensions with door opened at 90°:77 x 165 (w x d in cm)
• Shelf dimensions: 59 x 65 (w x d in cm)
• Max. loading capacity per shelf: 40 kg
• Weight: 157 kg / 183 kg (net / gross)
%
KIRSCH FROSTER LABO 530 PRO-ACTIVE laboratory freezer
Safe and worry-free storage of your laboratory samples at -30 °C. Guaranteed by the KIRSCH Airflow-Concept, automatic defrosting and much more.
GMP compliant, ensures a constant interior temperature even during defrosting.

KIRSCH-Airflow-Concept
• The world's smallest temperature deviations from the warmest to the coldest storage location thanks to PRO-ACTIVE control & KIRSCH-Airflow-Concept (ΔT= 2,5°C)
• PRO-ACTIVE control: permanent, proactive monitoring of performance data and alarms in the event of deviations (more information)
• Precise temperature control thanks to two PT-1000 temperature sensors
• Re-circulation air-cooling
• Rapid freezing funtion

Ergonomics-Concept
• Automatic defrosting and melt walter evaporation
• Door heating
• Ergonomics door opener
• Flexible interior fittings
• 5 shelves, height adjustable
• Castors

Safety and Digital Documentation
• Optical and acoustic alarm signal even in the event of a power failureMinimum / maximum temperature memory
• LED temperature display for easy readabilit
• Potential-free contact for connection to remote warning systems
• Data documentation can be read out as standard via USB interface using a USB stick and KIRSCH-DATANET software
• Lockable door

Options
• Modification for operation in the clean room
• Adjustable feet to compensate for uneven floors
• Additional wire shelves on mountings or support rails
• Drawers with support rails: 57 x 43 x 5.6 (w x d x h in cm)
• Aluminium trays , 60 x 40 x 2.5 (w x d x h in cm)
• Baskets with support rails: 60 x 45 x10 cm, 60 x 45 x 10 (w x d x h in cm)
• Water-cooled refrigerating machine
• GSM module
• Outer housing made of chrome-nickel steel 4301, longitudinally brushed
• PC-KIT-NET (network-compatible version)
• Pen-recording thermometer for placing loosely inside appliance with waxed paper strips
• Incorporated disc type pen-thermometer, 7-day recording time with recording discs (100 pack) and 5 felt tip pens
• Temperature sensor PT 100 or PT 1000 including built-in reference body (measurement bottle or refrigerating block)

Technical Specifications
• Temperature setting (approx.): -10 to -25 °C
• Voltage: 220 - 240 V
• Frequency: 50 / 60 Hz
• Power consumption: 227 Watts
• Average consumption: 4.42 KWh / 24 h
• Overall dimensions with door opened at 90°: 77 x 144 (w x d in cm)
• Shelf dimensions: 59 x 45 (w x d in cm)
• Max. loading capacity per shelf: 40 kg
• Weight: 140 kg / 163 kg (net / gross)"
%
KIRSCH FROSTER LABO 330 PRO-ACTIVE laboratory freezer
This laboratory freezer features re-circulating air cooling, a rapid defrosting system and a quick-freeze function. 4 plastic-coated shelves on mountings are fitted as standard. The shelves can optionally rest on support rails. Besides this standard option wire baskets on runners are also available.
• PRO-ACTIVE- Control:
Permanent, proactive monitoring of the performance data and alerts in the case of deviations – so that you can take countermeasures in good time before a fault threatens your chilled goods; world´s most accurate temperature control in refrigerated areas thanks to two standard PT-1000 sensors
• 4 shelves, height-adjustable
• Re-circulating air cooling
• Optimized ventilation plates to minimize interior temperature differences
• Additional warning in case of power failure (optical and acoustic)
• Rapid freezing cycle
• Easy-to-read LED temperature display
• Automatical defrosting and melt water evaporation
• Easy accessible control panel with key switch
• Micro-processor controlled temperature and thawing regulation to maximize temperature stability
• Minimum/maximum temperature memory
• Optical and acoustical alarm
• Data documentation can be read via USB interface with KIRSCH Datanet software.
• Potential free contact for alarm transmission
• Lockable door
Options
• Castors
• Compressor for 60 Hz operation
• Additional shelves mountings or support rails
• Additional drawers on telescopic runners
• Baskets with support rails: 56,8x40x10 cm
• GSM-Module
• PC-KIT-NET (Network capable version)
• Pen-recording thermometer for placing loosely inside appliance with waxed paper strips
• Disc-type pen-recording thermometer with 7-day measuring cycle with 100 recording discs and 5 felt tip pens
• Temperature probe PT 100 or PT 1000,
4 wire sensor, class 1/3 B, incl. measuring flask incorporated
Technical specifications
• Capacity 300 l
• Temperature setting (approx.) -10 to -30 °C
• Voltage 220 - 240 V
• Frequency 50 Hz
• Power consumption 590 Watts
• Average consumption 3,69 KWh / 24 h
• Overall dimensions (incl. distance from wall) 74 x 77 x 166 (w x d x h in cm)
• Interior dimensions 59,5 x 53 x 95 (w x d x h in cm)
• Overall dimensions with door
• opened at 90° 74 x 141 (w x d in cm)
• Shelf dimensions 57 x 42 (w x d in cm)
• Max. loading capacity per shelf 40 kg
• Weight 127 kg / 142 kg (net / gross)
%
KIRSCH LABEX® 720 PRO-ACTIVE laboratory refrigerator with explosion-proof interior
This laboratory refrigerator offers five standard integrated shelves and with 700 liters capacity plenty of storage space for your refrigerated goods. The forced air cooling ensures a nearly uniform temperature distribution in the interior, which is explosion-proof and intrinsically safe. The interior can be extended optional.
• PRO-ACTIVE- Control:
Permanent, proactive monitoring of the performance data and alerts in the case of deviations – so that you can take countermeasures in good time before a fault threatens your chilled goods; world´s most accurate temperature control in refrigerated areas thanks to two standard PT-1000 sensors.
• Re-circulating air cooling
• Castors
• Warning in case of power failure (optical and acoustic)
• 5 shelves, height-adjustable
• Explosion proof interior (LABEX®-Intrinsic Safety)
• Optimized ventilation plates to minimize interior temperature differences
• Automatic defrosting
• Meltwater tray for manual emptying
• Easy-to-read LED temperature display
• Easy accessible control panel with key switch
• Micro-processor controlled temperature and thawing regulation to maximize temperature stability
• Minimum/maximum temperature memory
• Safety device to prevent freezing
• Optical and acoustical alarm
• Data documentation can be read via USB interface with KIRSCH Datanet software.
• Potential free contact for alarm transmission
• Low-noise compressor
Options
• Insulating glass door with lock
• Adjustable feet to compensate for uneven floors.
• Additional shelves on mountings or support rails
• Basket on rails: 60x65x10 cm
• Aluminium tray with rails: 60x65x2,5 cm
• Outer housing in stainless stell 4301, longitudinal brushed
• GSM-Module
• PC-KIT-NET (Network capable version)
• Pen-recording thermometer for placing loosely inside appliance with waxed paper strips
• Temperature probe PT 100 or PT 1000,
• 4 wire sensor, class 1/3 B, incl. measuring flask incorporated
Technical specifications
• Capacity 700 l
• Temperature setting (approx.) +0 to +15 °C
• Voltage 220 - 240 V
• Frequency 50 / 60 Hz
• Power consumption 237 Watts
• Average consumption 1,23 KWh / 24 h
• Overall dimensions
• (incl. distance from wall) 77 x 98 x 195,5 (w x d x h in cm)
• Interior dimensions 62 x 77 x 140 (w x d x h in cm)
• Overall dimensions with door
• opened at 90° 77 x 165 (w x d in cm)
• Shelf dimensions 59 x 65 (w x d in cm)
• Max. loading capacity per shelf 40 kg
• Weight 145 kg / 174 kg (net / gross)
%
KIRSCH LABEX® 520 PRO-ACTIVE laboratory refrigerator with explosion-proof interior
The LABEX®-520 offers you with five standard integrated shelves and 500 liters capacity plenty of storage space for your refrigerated goods. The interior is completely flexible adapting to your needs. The interior is explosion-proof and intrinsically safe. A glass door can also be ordered optionally.
• PRO-ACTIVE- Control:
Permanent, proactive monitoring of the performance data and alerts in the case of deviations – so that you can take countermeasures in good time before a fault threatens your chilled goods; world´s most accurate temperature control in refrigerated areas thanks to two standard PT-1000 sensors.
• Re-circulating air cooling
• Castors
• Warning in case of power failure (optical and acoustic)
• 5 shelves, height-adjustable
• Explosion proof interior (LABEX®-Intrinsic Safety)
• Optimized ventilation plates to minimize interior temperature differences
• Automatic defrosting
• Meltwater tray for manual emptying
• Easy-to-read LED temperature display
• Easy accessible control panel with key switch
• Micro-processor controlled temperature and thawing regulation to maximize temperature stability
• Minimum/maximum temperature memory
• Safety device to prevent freezing
• Optical and acoustical alarm
• Data documentation can be read via USB interface with KIRSCH Datanet software.
• Potential free contact for alarm transmission
• Low-noise compressor
Options
• Insulating glass door with lock
• Adjustable feet to compensate for uneven floors.
• Additional shelves on mountings or support rails
• Conductive drawer: 57x39x5,6 cm
• Additional length and cross dividers for drawer
• Basket on rails: 60x45x10 cm
• Aluminium tray with rails: 60x45x2,5 cm
• Outer housing in stainless stell 4301, longitudinal brushed
• GSM-Module
• PC-KIT-NET (Network capable version)
• Pen-recording thermometer for placing loosely inside appliance with waxed paper strips
• Temperature probe PT 100 or PT 1000,
• 4 wire sensor, class 1/3 B, incl. measuring flask incorporated
Technical specifications
• Capacity: 500 l
• Temperature setting (approx.): +0 to +15 °C
• Voltage: 220 - 240 V
• Frequency: 50 / 60 Hz
• Power consumption: 234 Watts
• Average consumption: 1,2 KWh / 24 h
• Overall dimensions
• (incl. distance from wall): 77 x 76 x 195,5 (w x d x h in cm)
• Interior dimensions: 62 x 57 x 140 (w x d x h in cm)
• Overall dimensions with door
• opened at 90°: 77 x 144 (w x d in cm)
• Shelf dimensions: 59 x 45 (w x d in cm)
• Max. loading capacity per shelf: 40 kg
• Weight: 120 kg / 148 kg (net / gross)
%
KIRSCH LABEX® 468 PRO-ACTIVE laboratory refrigerator with explosion-proof interior
This laboratory refrigerator features 6 shelves as standard. Plastic drawer with adjustable longitudinal and cross dividers or aluminium trays on telescopic runners are available at an extra cost. All shelves and inserts are vertically adjustable and the device has an explosion-proof interior. A glass door can also be ordered optionally.
• PRO-ACTIVE- Control:
Permanent, proactive monitoring of the performance data and alerts in the case of deviations – so that you can take countermeasures in good time before a fault threatens your chilled goods; world´s most accurate temperature control in refrigerated areas thanks to two standard PT-1000 sensors
• Re-circulating air cooling
• 6 shelves, height-adjustable
• Warning in case of power failure (optical and acoustic)
• Explosion proof interior (LABEX®-Increased-Safety)
• Optimized ventilation plates to minimize interior temperature differences
• Automatic defrosting
• Meltwater tray for manual emptying
• Easy-to-read LED temperature display
• Easy accessible control panel with key switch
• Micro-processor controlled temperature and thawing regulation to maximize temperature stability
• Minimum/maximum temperature memory
• Safety device to prevent freezing
• Optical and acoustical alarm
• Data documentation can be read via USB interface with KIRSCH Datanet software.
• Potential free contact for alarm transmission
Options
• Insulating glass door
• Lock for glass door
• Decorative frame
• Castors
• Additional shelves on mountings or support rails
• Drawers on telescopic runners: 57x43x5,6 cm
• Additional length and cross dividers for drawer
• GSM-Module
• PC-KIT-NET (Network capable version)
• Pen-recording thermometer for placing loosely inside appliance with waxed paper strips
• Temperature probe PT 100 or PT 1000,
• 4 wire sensor, class 1/3 B, incl. measuring flask incorporated
Technical specifications
• Capacity: 460 l
• Temperature setting (approx.): +0 to +15 °C
• Voltage: 220 - 240 V
• Frequency: 50 / 60 Hz
• Power consumption: 170 Watts
• Average consumption: 1,03 KWh / 24 h
• Overall dimensions
• (incl. distance from wall): 74 x 80 x 181 (w x d x h in cm)
• Interior dimensions: 60 x 57 x 128 (w x d x h in cm)
• Overall dimensions with door
• opened at 90°: 74 x 144 (w x d in cm)
• Drawer inner dimensions: 57 x 43 x 5,6 (w x d x h in cm)
• Shelf dimensions: 59 x 50 (w x d in cm)
• Max. loading capacity per drawer/shelf: 24 kg / 40 kg
• Weight: 112 kg / 125 kg (net / gross)