English
English
Magyar
Home
About us
Shop By Products
Shop By Brand
Contact us
blog
My Cart
Sign in
Public pricelist HUF
Prev
1
2
3
4
5
6
7
Next
Sort by
Relevance
Catalog price: High to Low
Catalog price: Low to High
Name - A to Z
Name - Z to A
Product Sequence Low to High
Product Sequence High to Low
All products
%
Binder CBF 170 CO₂ incubator
The BINDER CBF is the high-end CO₂ incubator with humidity control that is suitable for all sensitive incubation applications in GMP environments. It ensures consistent results including in cell-based assays with multiwell plates. This BINDER incubator is even suitable for complex cultivation experiments or individual environments with hypoxic conditions thanks to its comprehensive assortment of options and accessories.
PRODUCT BENEFITS
• Safe – cell cultures receive maximum protection against contamination
• Reliable – constant well-being conditions for the cells
• Smart – simple routine cleaning and convenient operation
• Economical – efficient operation without consumables
PRODUCT FEATURES
• Contamination-safe humidification system without water pan •
• Tried-and-tested anti-contamination concept with 180 °C hot air sterilization •
• Hot-air sterilizable CO₂ sensor with single-beam infrared technology •
• Seamless inner chamber made of stainless steel with flanges as shelf support system
• Fanless interior with Venturi CO₂ gas mixing nozzle
• Intuitive touchscreen controller
• Internal data logger, measured values can be read out in open format via USB Troubleshooting system with visual and acoustic alarms
• Interfaces: Ethernet, USB, zero-voltage alarm contact
• Fail-safe CO₂ system for protecting the pH of cell cultures
Compare
%
Binder CB 56 CO₂ incubator
The powerful and versatile CB CO₂ incubator is suitable for cell-based assays in drug and medical research. This BINDER incubator is also suitable for complex cultivation experiments or individual environments with hypoxic conditions thanks to its comprehensive range of options and accessories.
PRODUCT BENEFITS
• Safe – cell cultures receive maximum protection against contamination
• Reliable – constant, stable conditions for cell well-being
• Smart – simple routine cleaning and convenient operation
• Economical – efficient operation without consumables
PRODUCT FEATURES
• Optimized humidification system with condensation protection
• Proven anti-contamination concept with 180 °C hot-air sterilization
• Hot-air sterilizable CO₂ sensor with single-beam infrared technology
• Seamless stainless-steel inner chamber with flanges as shelf support system
• Fanless interior with Venturi CO₂ gas mixing nozzle
• Intuitive touchscreen controller
• Internal data recording, readable in open format via USB interface
• Fault diagnosis system with visual and acoustic alarm
• Interfaces: Ethernet, USB, zero-voltage alarm contact
• Fail-safe CO₂ system for protecting the pH of cell cultures
Compare
%
KIRSCH FROSTER LABEX 96 PRO-ACTIVE laboratory freezer with explosion-proof interior
The Labex® 96 is a powerful laboratory freezer with reduced energy consumption. Thanks to its compact design, it can be both built-in and under-counter - ideal for laboratories with limited space.
The explosion-proof interior (zone 2) offers maximum safety for sensitive samples and materials.
The integrated USB interface ensures complete data documentation: data can be conveniently read out using a USB stick and analysed using the KIRSCH Datanet software.
Features
• Temperature setting (approx.): -5 °C – -25°C
• PRO-ACTIVE- Control: Permanent, proactive monitoring of the performance data and alerts in the case of deviations – so that you can take countermeasures in good time before a fault threatens your chilled goods; world´s most accurate temperature control in refrigerated areas thanks to two standard PT-1000 sensors
• Digital temperature display
• Adjustable height grids, load capacity 25kg/grid
• Adjustable feet to compensate uneven floors
• Removable condensation container
• Manual defrosting
• Rapid freezing cycle
• Door frame heater prevents icing of the door
• Key switch protected control panel against tampering
• Optical and acoustic alarm
• Membrane keyboard with digital temperature display and minimum/maximum temperature memory
• Lockable door
Compare
%
Vestfrost VT75 Laboratory Chest Freezer
The Vestfrost VT75 is a compact low-temperature laboratory chest freezer capable of maintaining temperatures down to −60 °C. It is an ideal solution for smaller laboratories, hospital departments, and research facilities requiring secure and stable cold storage in a limited space.
Product Features
• Temperature range: −40 °C to −60 °C
• Static cooling, Nature R environmentally friendly refrigerant
• 80 mm thick polyurethane insulation with cyclopentane
• Energy consumption: 2.24 kWh / 24 hours
• XR30CX digital controller with temperature and probe failure alarms
• 1 steel basket with plastic coating
• Easy-to-clean painted steel interior
• Ø12 mm porthole for external probe connection
• Lockable solid lid
• Compact design (net volume: 71 L), no castors
• Ideal for the secure low-temperature storage of small quantities of samples, reagents, and pharmaceuticals
Compare
%
Binder KBF 260 Photostability Climat Chamber with ICH light modul with light-dose control (LQC)
The Binder KBF 260 standard climate chamber offers a reliable solution for photostability testing in accordance with the ICH Q1B guideline. The unit can be easily equipped with the ICH LQC light module, which provides UV and visible (VIS) light to create a standardized test environment. The ICH LQC module also includes a VIS and a UVA sensor for precise light dose control. The lighting switches off automatically once the programmed light dose reaches the desired value, ensuring that the test is carried out under fully controlled conditions. The system is designed so that the photostability test can be completed within three days while minimizing thermal impact on the test material.
KBF models provide a stable and controlled environment, making them ideal for industrial and research-based photostability applications where the reproducibility of test results is a key requirement.
Scope of delivery
Binder KBF 260 Constant climate chambers with a large temperature / humidity range
• Climate range: +20 °C to +50 °C and 20% to 50% RH
• Proven APT.line ™ preheating chamber technology
• Energy-efficient cooling with modern inverter cooling unit
• Cooling with climate-neutral R-600a refrigerant
• Door heating to prevent condensation
• Adjustable fan speed
• Humidity regulation with capacitive humidity sensor and responsive steam humidification
• Robust housing design with HIT sandwich technology
• Stainless steel inner chamber
• Inner doors made of metal oxide-coated safety glass
• Two racks made of stainless steel
• Large access ports with silicone plug
• Robust twin casters, with brakes at the front
• Intuitive touchscreen controller with time-segment and real-time programming
• Internal data logger, measured values can be read out in open format via USB
• Class 3.3 independent temperature safety device (DIN 12880) with visual and acoustic alarms
• Unit self-test for comprehensive status analysis
• Data interfaces: Ethernet, USB
• BINDER Multi Management Software APT-COM™ basic edition
BINDER ICH-LQC light module
The ICH-LQC light module contains two spherical light sensors in addition. The VIS sensor measures the illuminance of visible light and the UVA sensor measures the irradiance of UVA light. Both sensors evaluate the light with a spherical characteristic, which is useful for three-dimensional test objects. The light dose must be increased by a factor of 1.5 for photostability tests on flat test objects, such as printed products.
The ICH light module is also connected to the climate chamber via a data cable and the light control runs via the program controller. The light dose to be achieved for the two types of light is entered in the controller (typically 1.2 Mlx h visible light and 200 Wh/m² UVA) and the light cassettes are automatically switched off individually once the dose has been reached.
Scope of delivery of the BINDER ICH-LQC light module
• VIS light cassette with connection cable
• UVA light cassette with connection cable
• Spherical VIS light sensor for light dose control
• Spherical UVA light sensor for light dose control
• U-rails for mounting the light cassettes in the climate control cabinet
• Supply box with ballasts/power supply units
• Profile rails and bolts for attaching the supply box to the climate chamber
• Data cable
• Mains cable
• Operating instructions
Compare
%
Binder KBF PRO 260 Photostability Climat Chamber with ICH light modul with light-dose control (LQC)
The Binder KBF PRO 260 standard climate chamber with extended temperature and humidity range is an ideal choice for photostability testing in accordance with the ICH Q1B guideline. The unit can be easily equipped with the ICH LQC light module, which provides UV and visible (VIS) light to create a standardized test environment. The ICH LQC module also includes a VIS and a UVA sensor for precise light dose control. The lighting switches off automatically once the programmed light dose reaches the desired value, ensuring that the test is carried out under fully controlled conditions. The system is designed so that the photostability test can be completed within three days while minimizing thermal impact on the test material.
Scope of delivery
Binder KBF PRO 260 Constant climate chamber with expanded temperature / humidity range
• Climate range: +10 °C to +50 °C and 10% to 80% RH
• Proven APT.line ™ preheating chamber technology
• Energy-efficient cooling with modern inverter cooling unit
• Cooling with climate-neutral R-290 refrigerant
• Door heating to prevent condensation
• Adjustable fan speed
• Humidity regulation with capacitive humidity sensor and responsive steam humidification
• Robust housing design with HIT sandwich technology
• Stainless-steel inner chamber
• Inner doors made of metal oxide-coated safety glass
• Two racks made of stainless steel with telescopic rails
• Large access port with silicone plug
• Robust twin casters, with brakes at the front
• Intuitive touchscreen controller with time-segment and real-time programming
• Internal data logger, measured values can be read out in open format via USB
• Class 3.3 independent temperature safety device (DIN 12880) with visual and acoustic alarms
• Unit self-test for comprehensive status analysis
• Data interfaces: Ethernet, USB
• BINDER Multi Management Software APT-COM™ basic edition
BINDER ICH-LQC light module
The ICH-LQC light module contains two spherical light sensors in addition. The VIS sensor measures the illuminance of visible light and the UVA sensor measures the irradiance of UVA light. Both sensors evaluate the light with a spherical characteristic, which is useful for three-dimensional test objects. The light dose must be increased by a factor of 1.5 for photostability tests on flat test objects, such as printed products.
The ICH light module is also connected to the climate chamber via a data cable and the light control runs via the program controller. The light dose to be achieved for the two types of light is entered in the controller (typically 1.2 Mlx h visible light and 200 Wh/m² UVA) and the light cassettes are automatically switched off individually once the dose has been reached.
Scope of delivery of the BINDER ICH-LQC light module
• VIS light cassette with connection cable
• UVA light cassette with connection cable
• Spherical VIS light sensor for light dose control
• Spherical UVA light sensor for light dose control
• U-rails for mounting the light cassettes in the climate control cabinet
• Supply box with ballasts/power supply units
• Profile rails and bolts for attaching the supply box to the climate chamber
• Data cable
• Mains cable
• Operating instructions
Compare
%
Binder KB PRO 260 Photostability Test Chamber with ICH light modul with light-dose control (LQC)
The Binder KB PRO 260 incubator is an ideal choice for photostability testing in accordance with ICH guideline Q1B. The unit can be easily equipped with the ICH LQC light module, which provides UV and visible (VIS) light to create a standardized test environment. The ICH LQC module also includes a VIS and a UVA sensor for precise light dose control. The lighting switches off automatically once the programmed light dose reaches the desired value, ensuring that the test is carried out under fully controlled conditions. The system is designed so that the photostability test can be completed within three days while minimizing thermal impact on the test material.
Scope of delivery
Binder KB PRO 260 Cooling incubator
• Temperature range: +5 °C bis +60 °C
• Proven APT.line ™ preheating chamber technology
• Energy-efficient cooling with modern inverter cooling unit
• Cooling with climate-neutral R-290 refrigerant
• Door heating to prevent condensation
• Adjustable fan speed
• Robust housing design with HIT sandwich technology
• Stainless-steel inner chamber
• Inner doors made of metal oxide-coated safety glass
• Two racks made of stainless steel
• Large access port with silicone plug
• Robust twin casters, with brakes at the front
• Intuitive touchscreen controller with time-segment and real-time programming
• Internal data logger, measured values can be read out in open format via USB
• Class 3.3 independent temperature safety device (DIN 12880) with visual and acoustic alarms
• Unit self-test for comprehensive status analysis
• Data interfaces: Ethernet, USB
• BINDER Multi Management Software APT-COM™ basic edition
BINDER ICH-LQC light module
The ICH-LQC light module contains two spherical light sensors in addition. The VIS sensor measures the illuminance of visible light and the UVA sensor measures the irradiance of UVA light. Both sensors evaluate the light with a spherical characteristic, which is useful for three-dimensional test objects. The light dose must be increased by a factor of 1.5 for photostability tests on flat test objects, such as printed products.
The ICH light module is also connected to the climate chamber via a data cable and the light control runs via the program controller. The light dose to be achieved for the two types of light is entered in the controller (typically 1.2 Mlx h visible light and 200 Wh/m² UVA) and the light cassettes are automatically switched off individually once the dose has been reached.
Scope of delivery of the BINDER ICH-LQC light module
• VIS light cassette with connection cable
• UVA light cassette with connection cable
• U-rails for mounting the light cassettes in the climate control cabinet
• Supply box with ballasts/power supply units
• Profile rails and bolts for attaching the supply box to the climate chamber
• Data cable
• Mains cable
• Operating instructions
• Spherical VIS light sensor for light dose control
• Spherical UVA light sensor for light dose control
Compare
%
Binder KBF 260 Photostability Climat Chamber with ICH light modul
The Binder KBF 260 standard climate chamber offers a reliable solution for photostability testing in accordance with the ICH Q1B guideline. The chamber can optionally be equipped with an ICH-compatible light module that provides standardized UV and visible light (VIS) exposure for the samples. The unit is designed to enable accurate and efficient execution of the three-day photostability test with minimal thermal impact. KBF models provide a stable and controlled environment, making them ideal for industrial and research-based photostability applications where the reproducibility of test results is a key requirement.
Scope of delivery
Binder KBF 260 Constant climate chambers with a large temperature / humidity range
• Climate range: +20 °C to +50 °C and 20% to 50% RH
• Proven APT.line ™ preheating chamber technology
• Energy-efficient cooling with modern inverter cooling unit
• Cooling with climate-neutral R-600a refrigerant
• Door heating to prevent condensation
• Adjustable fan speed
• Humidity regulation with capacitive humidity sensor and responsive steam humidification
• Robust housing design with HIT sandwich technology
• Stainless steel inner chamber
• Inner doors made of metal oxide-coated safety glass
• Two racks made of stainless steel
• Large access ports with silicone plug
• Robust twin casters, with brakes at the front
• Intuitive touchscreen controller with time-segment and real-time programming
• Internal data logger, measured values can be read out in open format via USB
• Class 3.3 independent temperature safety device (DIN 12880) with visual and acoustic alarms
• Unit self-test for comprehensive status analysis
• Data interfaces: Ethernet, USB
• BINDER Multi Management Software APT-COM™ basic edition
ICH light module without light dose control
The ICH light module is connected to the climate chamber via a data cable. This makes it possible to control the irradiation duration of the light cassettes individually with a time segment program via the program controller of the climate chamber.
Scope of delivery of the BINDER ICH light modules
• VIS light cassette with connection cable
• UVA light cassette with connection cable
• U-rails for mounting the light cassettes in the climate control cabinet
• Supply box with ballasts/power supply units
• Profile rails and bolts for attaching the supply box to the climate chamber
• Data cable
• Mains cable
• Operating instructions
Compare
%
Binder KBF PRO 260 Photostability Climat Chamber with ICH light modul
The Binder KBF PRO 260 standard climate chamber with extended temperature and humidity range is an ideal choice for photostability testing in accordance with the ICH Q1B guideline. The chamber can be equipped with a special ICH light module that provides standardized UV and visible light (VIS) exposure. The system is designed to enable fast and reliable completion of the three-day photostability test with minimal thermal impact. The KBF PRO 260 ensures a precise and stable environment, guaranteeing the reproducibility of test results in various industrial and research applications.
Scope of delivery
Binder KBF PRO 260 Constant climate chamber with expanded temperature / humidity range
• Climate range: +10 °C to +50 °C and 10% to 80% RH
• Proven APT.line ™ preheating chamber technology
• Energy-efficient cooling with modern inverter cooling unit
• Cooling with climate-neutral R-290 refrigerant
• Door heating to prevent condensation
• Adjustable fan speed
• Humidity regulation with capacitive humidity sensor and responsive steam humidification
• Robust housing design with HIT sandwich technology
• Stainless-steel inner chamber
• Inner doors made of metal oxide-coated safety glass
• Two racks made of stainless steel with telescopic rails
• Large access port with silicone plug
• Robust twin casters, with brakes at the front
• Intuitive touchscreen controller with time-segment and real-time programming
• Internal data logger, measured values can be read out in open format via USB
• Class 3.3 independent temperature safety device (DIN 12880) with visual and acoustic alarms
• Unit self-test for comprehensive status analysis
• Data interfaces: Ethernet, USB
• BINDER Multi Management Software APT-COM™ basic edition
ICH light module without light dose control
The ICH light module is connected to the climate chamber via a data cable. This makes it possible to control the irradiation duration of the light cassettes individually with a time segment program via the program controller of the climate chamber.
Scope of delivery of the BINDER ICH light modules
• VIS light cassette with connection cable
• UVA light cassette with connection cable
• U-rails for mounting the light cassettes in the climate control cabinet
• Supply box with ballasts/power supply units
• Profile rails and bolts for attaching the supply box to the climate chamber
• Data cable
• Mains cable
• Operating instructions
Compare
%
Binder KB PRO 260 Photostability Test Chamber with ICH light modul
The Binder KB PRO 260 incubator is an ideal choice for photostability testing in accordance with ICH guideline Q1B. The unit can be easily equipped with an ICH light module, which provides UV and visible (VIS) light to create a standardized test environment. The system is designed to complete the photostability test within three days while minimizing thermal impact on the test material.
Scope of delivery
Binder KB PRO 260 Cooling incubator
• Temperature range: +5 °C bis +60 °C
• Proven APT.line ™ preheating chamber technology
• Energy-efficient cooling with modern inverter cooling unit
• Cooling with climate-neutral R-290 refrigerant
• Door heating to prevent condensation
• Adjustable fan speed
• Robust housing design with HIT sandwich technology
• Stainless-steel inner chamber
• Inner doors made of metal oxide-coated safety glass
• Two racks made of stainless steel
• Large access port with silicone plug
• Robust twin casters, with brakes at the front
• Intuitive touchscreen controller with time-segment and real-time programming
• Internal data logger, measured values can be read out in open format via USB
• Class 3.3 independent temperature safety device (DIN 12880) with visual and acoustic alarms
• Unit self-test for comprehensive status analysis
• Data interfaces: Ethernet, USB
• BINDER Multi Management Software APT-COM™ basic edition
ICH light module without light dose control
The ICH light module is connected to the climate chamber via a data cable. This makes it possible to control the irradiation duration of the light cassettes individually with a time segment program via the program controller of the climate chamber.
Scope of delivery of the BINDER ICH light modules
• VIS light cassette with connection cable
• UVA light cassette with connection cable
• U-rails for mounting the light cassettes in the climate control cabinet
• Supply box with ballasts/power supply units
• Profile rails and bolts for attaching the supply box to the climate chamber
• Data cable
• Mains cable
• Operating instructions
Compare
%
Liebherr SFTsg 1501 laboratory freezer
Sensitive substances are optimally stored and protected in this undercounter freezer for laboratories. The high-performance freezer impresses with reliable temperature stability and assorted safety functions, as well as SmartFrost, which significantly reduces frost buildup in the interior.
Product features
• ±5 °C temperature stability
Sensitive substances cannot be subjected to large deviations from the set storage temperature. Liebherr freezers guarantee a minimal temperature fluctuation of no more than ±5 °C. This means that your valuable contents are optimally protected against impairment and their quality is preserved.
• SmartFrost
SmartFrost reduces frost build-up in the interior and on stored products. Defrosting is required less often – and when it is necessary, it is made much easier by the smooth, easy-to-clean interior walls. The evaporator in the foam insulation ensures high levels of energy efficiency as well as even cooling.
• Retrofittable WiFi/LAN interface
This is how easy it is to network a Liebherr: With the retrofittable WiFi and LAN interface, appliances can be effortlessly connected to external systems, such as SmartMonitoring from Liebherr. With the digital monitoring solution, the storage temperature is controlled and documented conveniently and securely via the subsequently set up interface.
• SmartMonitoring (optional)
The cloud-based digital solution continuously monitors and documents temperatures and alerts you immediately via email, text message or phone if any deviations occur
• Designed for a service life of 15 years
Sustainable means the appliance is not only economical, but also durable. High-quality materials and solid workmanship, coupled with at least ten years of spare parts availability, make a Liebherr appliance a robust, reliable, and extremely long-lasting top performer in demanding everyday work.
• Easy to clean interior
The plastic inside container is made of polystyrene: a fully recyclable, robust, and odourless plastic. Manufactured seamlessly from one piece, it has no hidden dirt traps and the large corner radii can be cleaned quickly and easily. The perfect combination of sustainability and hygiene.
• Alarm relay
In the event of an alarm, the responsible control centre is informed immediately, usually through connection to the building control system. You can define in advance which alarms are to be forwarded, as well as set how long the forwarding remains active and whether a reminder should be sent after the alarm acknowledgement. This allows you to react immediately in critical situations.
• Replaceable door seal
Save time and money: Liebherr's plug-in door seals can be easily replaced. If a seal is damaged, you can replace it yourself without any tools.
• Mechanical lock
Liebherr professional appliances are equipped with a mechanical lock and two keys. This ensures that unauthorized persons cannot access your valuable and sensitive stored goods.
• Feedthrough for external sensors
To additionally control the storage temperature with the help of a separate sensor, wiring from the outside to the inside is required. The cable feeding offers a clean and professional solution here. The integrated opening allows connection without drilling holes or breaking the door seal.
• Min./max. temperature recording
Always keep an eye on the temperature: Min./max. temperature recording stores the minimum and maximum temperature values of the interior that have occurred from a defined start time and shows them clearly in the display. This way you can be sure that, up until the moment you read off the values, the storage temperatures were always within the tolerated limits.
Compare
%
Liebherr SFTfg 1501 laboratory freezer with explosion-proof interior container
Conforms to the ATEX directive and meets exacting requirements in terms of safety, temperature stability, and ease of use: This undercounter freezer for laboratories is suitable for the reliable storage of closed containers containing combustible substances that could form explosive atmospheres.
Product features
• Compliance with the ATEX Directive
Liebherr laboratory equipment conforms to EN/IEC 60079-0 or EN-IEC 60079-7 and complies with EU Directive 2014/34/EU (“ATEX Directive”). Classification of the interior to <Ex> II 3 G Ex ec IIC T6 (declared as Zone 22) makes them suitable for flammable substances in closed containers that could form explosive atmospheres.
• ±5 °C temperature stability
Sensitive substances cannot be subjected to large deviations from the set storage temperature. Liebherr freezers guarantee a minimal temperature fluctuation of no more than ±5 °C. This means that your valuable contents are optimally protected against impairment and their quality is preserved.
• SmartFrost
SmartFrost reduces frost build-up in the interior and on stored products. Defrosting is required less often – and when it is necessary, it is made much easier by the smooth, easy-to-clean interior walls. The evaporator in the foam insulation ensures high levels of energy efficiency as well as even cooling.
• Retrofittable WiFi/LAN interface
This is how easy it is to network a Liebherr: With the retrofittable WiFi and LAN interface, appliances can be effortlessly connected to external systems, such as SmartMonitoring from Liebherr. With the digital monitoring solution, the storage temperature is controlled and documented conveniently and securely via the subsequently set up interface.
• SmartMonitoring (optional)
The cloud-based digital solution continuously monitors and documents temperatures and alerts you immediately via email, text message or phone if any deviations occur
• Designed for a service life of 15 years
Sustainable means the appliance is not only economical, but also durable. High-quality materials and solid workmanship, coupled with at least ten years of spare parts availability, make a Liebherr appliance a robust, reliable, and extremely long-lasting top performer in demanding everyday work.
• Easy to clean interior
The plastic inside container is made of polystyrene: a fully recyclable, robust, and odourless plastic. Manufactured seamlessly from one piece, it has no hidden dirt traps and the large corner radii can be cleaned quickly and easily. The perfect combination of sustainability and hygiene.
• Alarm relay
In the event of an alarm, the responsible control centre is informed immediately, usually through connection to the building control system. You can define in advance which alarms are to be forwarded, as well as set how long the forwarding remains active and whether a reminder should be sent after the alarm acknowledgement. This allows you to react immediately in critical situations.
• Replaceable door seal
Save time and money: Liebherr's plug-in door seals can be easily replaced. If a seal is damaged, you can replace it yourself without any tools.
• Mechanical lock
Liebherr professional appliances are equipped with a mechanical lock and two keys. This ensures that unauthorized persons cannot access your valuable and sensitive stored goods.
• Feedthrough for external sensors
To additionally control the storage temperature with the help of a separate sensor, wiring from the outside to the inside is required. The cable feeding offers a clean and professional solution here. The integrated opening allows connection without drilling holes or breaking the door seal.
• Min./max. temperature recording
Always keep an eye on the temperature: Min./max. temperature recording stores the minimum and maximum temperature values of the interior that have occurred from a defined start time and shows them clearly in the display. This way you can be sure that, up until the moment you read off the values, the storage temperatures were always within the tolerated limits.
Compare
%
Vestfrost ULTF-91i Ultra low temperature freezer
With the smallest footprint, these units are perfect for storing biomedical content in a room with limited space.
The units can be placed on a table for easy access in your work environment. The units can operate within -20 to -86 giving you flexibility to adjust the cooling to your specific needs.
Product features
• Can be placed on a table
• Temperature range: -20 to -86 °C
• Number of compressors: 1
• Weight netto: 102 kg
• Material inner cabinet: Stainless steel
• Material outer cabinet: Painted steel
• Insulation type: Polyurethane with cyclopentane
• Lock
• Battery backup
• Porthole size: 20 mm
• Dry contact
• Vacuum valve
• Alarms: High / Low temperature, Open door, Power failure, Probe failure
• Noise: < 48 dB
• Refrigerant/amount: Nature R 2/149gr
• Internal air distribution: Static
• USB Connection
• Controller: i-CARE touch, Logging of data & alarms
Compare
%
Binder KB PRO 260 plant growth chamber with LED plant light module
The Binder KB PRO 260 cooling incubator with extended temperature range is easily convertible for plant growth applications, thanks to the integrated LED lighting modules. The intuitive control unit can be mounted externally using the included mounting elements, while the LED light strips can be flexibly arranged inside the chamber using metal clips. The system offers three independently controllable color channels (warm white, cool white, deep red), which can be programmed in real time to precisely match the needs of plants during every growth stage.
Package Includes
Binder KB PRO 260 Cooling Incubator with Extended Temperature Range
• Temperature range: +18°C to +32°C
• Proven APT.line™ preheating chamber technology
• Energy-efficient cooling with a modern inverter-based cooling unit
• Eco-friendly cooling using R-290 refrigerant
• Heated door to prevent condensation
• Adjustable fan speed
• Housing design with HIT technology
• Stainless steel inner chamber
• Inner doors made of safety glass with metal oxide coating
• Two stainless steel shelves with telescopic rails
• Large access port with silicone plug
• Floor-standing design with robust twin casters and front brakes
• Stackable benchtop models up to 130 liters
• Intuitive touchscreen controller with segmented and real-time programming
• Built-in data logger with USB export in open format
• Independent Class 3.3 temperature safety device (DIN 12880) with visual and audible alarms
• Self-diagnostic system with comprehensive status analysis
• Data interfaces: Ethernet, USB
• BINDER Multi Management Software APT-COM™ basic version included
Binder ICH Lighting Module for Plant Cultivation
• 16 LED light strips with mounting clips
• Lighting control unit with programmable controller, power supply, and fresh air pump
• Mounting rails and screws for the lighting control unit
• Special silicone foam plugs for sealing cable ports
• Cabling included
Control Unit Functions
• Three color channels (warm white, cool white, deep red), individually adjustable from 10% to 100%
• Real-time programming
• Dimming/twilight simulation function
• Ventilation function
Compare
%
Stakpure WEA 20 Duo 1 cabinet water softener
Double system, volume-controlled in compact design, for softening ironand manganese-free drinking water, in accordance with the Drinking Water Ordinance, fully automatic 5-stage central control valve type 9100 SE with intelligent control electronics made of gunmetal with adapter for the second pressure vessel. 2 pressure tanks made of corrosion-resistant GRP, including a high-quality cation exchanger. 1 cabinet brine tank with a sieve floor and a float valve (safety valve).
Technical data
• Maximum flow rate: 1.9 m³/h at 1.6 bar pressure loss
• Resin quantity: 2 x 5 litres
• Salt consumption: approx. 1.2 kg/reg.
• Operating pressure: 3 to 6 bar
• Max. water temperature: 40°C
• Max. ambient temperature: 5 to 40°C
• Dimensions of housing: approx. W 585 x D 555 x H 622 mm
• Electrical connection: 230 V 50 Hz
• Water connection: R 1’
• waste water connection R ½’
Compare
%
Sigma 1-7 laboratory benchtop centrifuge
The Sigma 1‑7 is designed for the separation of blood and urine specimens in medical practices and small labs, and due to its strong performance it is also used in environmental analytics, schools and universities.
The Sigma 1‑7 compact benchtop centrifuge is especially good in delivering exact results in a very short time. With these attributes combined with convenient, intuitive operation and the motorised lid lock, which enables effortless closing of the centrifuge, it offers more than comparable devices in its segment.
What makes the Sigma 1‑7 benchtop centrifuge so attractive?
The Sigma 1‑7 benchtop centrifuge is the only one in its segment that supports up to ten saved programs. This allows routine protocols to be stored and work processes to be optimised. In operation this small centrifuge runs with especially low vibration, quietly and pleasantly.
The perfectly matched fixed-angle rotor of the Sigma 1‑7, with a maximum capacity of 6 x 15 ml, is well suited to meet the demands of small volumes of specimens. The maximum RCF of 6,153 x g and the short braking and acceleration times of this small centrifuge allow separation times to be shortened considerably.
Product options
Centrifuge & rotor package
Applications: Doctors in private practice, Veterinary practices, Small laboratory workstations, Hospitals
Compare
%
Liebherr SFFvh 4001 laboratory freezer
Liebherr freezers for laboratory and research use meet the highest requirements, especially in terms of safety and temperature stability.
• Integrated data logger
The integrated logger records the temperature profile, alarm history and service information for up to five years. The data can be read out directly from the appliance via the USB interface.
• Min./max. temperature log
The min./max. temperature log stores the minimum and maximum interior temperatures and shows on the display whether the storage temperatures were within the tolerance limits.
• +2 °C SafetyDevice
If the temperature falls below +2 °C due to a malfunction, the SafetyDevice takes control, stabilising the temperature, activating the alarm and protecting the contents from freezing
• Power failure alarm
If a malfunction occurs, an integrated battery provides a visual and audible alarm and takes over the power supply. As soon as the power is restored, the time of failure and the maximum temperature reached are displayed.
• LightAlarm
In the event of an uncontrolled temperature rise or other problems, the interior light of the appliance starts flashing. This visually shows when action is needed.
• Feedthrough for external sensors
An integrated opening allows a separate sensor to be connected for additional temperature monitoring without having to drill holes or break the door seal.
• Mechanical lock
Liebherr professional appliances are equipped with a mechanical lock and two keys. This ensures that unauthorised persons cannot access your valuable and sensitive stored goods.
• SmartMonitoring
The cloud-based digital solution continuously monitors and documents temperatures and alerts you immediately via email, text message or phone if any deviations occur.
• Integrated WiFi/LAN interface
The integrated WiFi/LAN interface enables you to easily connect your appliances with Liebherr SmartMonitoring or existing local systems.
• Easy-to-clean interior
The inner liner made of fully recyclable, robust and odourless polystyrene is manufactured in one piece without joints. This makes it quick and easy to clean the large, rounded corners.
• Replaceable door seal
Save time and money: the insertable Liebherr door seals are easy to change. If a seal is damaged, you can replace it yourself without any tools. Contact Liebherr Customer Service to purchase replacements.
• Self-closing door < 90°
To make loading, unloading and cleaning easier, the appliance door stays open if opened by more than 90°. If the opening angle is less than 90°, it closes automatically for safety
• NoFrost technology
Liebherr professional laboratory appliances no longer need manual defrosting. Any moisture that occurs is bound by the fan-assisted cooling, and when necessary, defrosting phases remove any remaining moisture particles from of the interior – for convenient, safe, and ice-free storage.
• ±5 °C temperature stability
Sensitive substances cannot be subjected to large deviations from the set storage temperature. Liebherr freezers guarantee a temperature fluctuation of no more than ±5 °C, so that the valuable goods you store in them are optimally protected and their quality is preserved.
• Standard compliance
The devices fully comply with the DIN 13277 standard and the IEC 61010-2-011 standard.
Compare
%
Binder M 56 drying and heating chamber with forced convection and advanced program functions
With a maximum of +300 °C and various programming options the M series material test chambers are ideal for material and aging tests. With a high air flow, the powerful fans ensure rapid heating.
BENEFITS
• Uniform drying conditions thanks to APT.line™ technology
• Identical test conditions throughout the chamber interior independent of sample size and quantity
• Outstanding thermal insulation saves operation costs
• Advanced programming options
IMPORTANT CHARACTERISTICS
Temperature range: +22°C above ambient temperature to +300°C
High temperature accuracy thanks to APT.line™ technology with increased heating output
Reinforced fan with adjustable speed
Electromechanical control of the exhaust air flap
Intuitive touchscreen controller with time-segment and real-time programming
2 chrome-plated racks
Class 2 independent adjustable temperature safety device (DIN 12880) and class 3.1 independent temperature safety device (DIN 12880) with visual/ acoustic alarm available for selection on the controller
Failsafe function – backup sensor Pt 100
Computer interface: Ethernet
Internal data logger, measured values can be read out in open format via USB
Compare
%
Binder FP 53 drying and heating chamber with forced convection and program functions
A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and particularly fast heating – even for chambers under full loads.
Product benefits
• Uniform drying conditions thanks to APT.line™ technology
• Identical test conditions throughout the chamber interior independent of sample size and quantity
• Outstanding thermal insulation saves operation costs
• Advanced programming options
Main features
• Temperature range: +10 °C above ambient temperature up to +300 °C
• High temperature accuracy thanks to APT.line™ technology
• Adjustable fan speed
• Controller with interval and real-time programming
• Electromechanical control of the exhaust air flap
• 2 chrome-plated racks
• Units up to 115 liters are stackable
• Class 2 independent adjustable temperature safety device (DIN 12880) and class 3.1 independent temperature safety device (DIN 12880) with visual/acoustic alarm available for selection on the controller
• Ergonomic handle design
• Computer interface: Ethernet
• Internal data logger, measured values can be read out in open format via USB
Compare
%
Hei-PLATE Mix'n'Heat Expert magnetic stirrer with heating
Well-designed features for a carefree stirring and heating.
The magnetic stirrer Hei-PLATE Mix 'n' Heat Expert convinces with its intuitive handling: Thanks to respectively one display per main function (stirring and heating), you have an easily legible eye on all values and settings at any time. The handling is made via two push-and-rotary controls with LED-rings for an easy identification of the active functions. Separate timers for heating and stirring functions create flexibility and let you control your experiments better. The user-friendly menu navigation makes working with this device particularly easy.
For controlling the temperature, you can choose between three heating modes: FAST for a particularly quick heating, as well as PRECISE and PRECISE+ for a particularly exact control of your target temperature without overshoot - this is how sensitive samples are optimally protected. Therefore, the device is compatible with the temperature sensor Pt1000 as well as the double sensor Pt1000 that allows the measurement in your sample and in the bath liquid simultaneously.
For the stirring speed, there is a three-stage setting (start-up behavior). Furthermore, you can set the rotational direction of the magnetic stirring bar and benefit from the automatic stir bar detector. As a result, your sample is optimally stirred at any time, even when there are irregularities while stirring.
This magnetic stirrer is equipped with the most important safety features. The large safety distance between the heating plate and the control panel, as well as the visual residual heat indicator at temperatures > 50 °C, protect against burns.
The patented Kera-Disk® plate made of anodized aluminum is chemical-resistant, scratch-resistant and has a diameter of 145 mm (also available with 135 mm on request). This makes it suitable for the use with many accessories and samples on a small footprint. Moreover, the material used allows the fastest heating times.
Technical data
• Dimensions (w/d/h): 168 x 299 x 106 mm
• Usable Surface heating plate: 145 mm
• Weight: 3 kg
• Max. Load: 25 kg
• Drive: EC motor, counterclockwise/clockwise rotating
• Rotation speed range: 100 – 1,400 rpm
• Heating power: 800 W at 230 V (EU) 600 W at 115 V (US)
• Temperature range: 20 – 350 °C, setting accuracy 1 K
• Heating control: PID
• Temperature measurement accuracy: Operation with external temperature measuring sensor Pt1000: ± 0.2 K, plus tolerance Pt1000
• Temperature measurement resolution: 0,1 K
• Display: 2 x TFT display
• Protection class (EN 60529): IP 42
• Acoustic pressure: < 50 db(A)
• Rated Voltage: 230 V, 50/60 Hz (EU) 115 V, 50/60 Hz (US)
• Connection: L+N+PE
• Protection class IEC 60529: I
• Overvoltage Category: II
• Degree of pollution: 2
• Power input: Normal operation 230 V: 825 W (EU) / 115 V: 625 W (US) Standby mode: 1.7 W
• EMC class: B, Group 1
• Permissible ambient conditions: 5 – 31 °C at up to 80 % rel. humidity, 32 – 40 °C at up to 50 % rel. humidity (linearly reducing)
• Installation altitude: up to 2,000 m asl
Compare
Prev
1
2
3
4
5
6
7
Next