English
English
Magyar
Home
About us
Shop By Products
Shop By Brand
Contact us
blog
My Cart
Sign in
Public pricelist HUF
Prev
1
2
3
4
5
6
7
Next
Sort by
Relevance
Catalog price: High to Low
Catalog price: Low to High
Name - A to Z
Name - Z to A
Product Sequence Low to High
Product Sequence High to Low
All products
All Products
Brand
Bandelin
Bimos
Binder
Düperthal
Esco
Fedegari
Fumex
Heidolph
HP Labortechnik
Julabo
Kirsch
Kühner
Liebherr
Miele
Nabertherm
Ohaus
Sigma
Stakpure
Vacuubrand
Waldner
Products
Autoclaves
Bioreactors
Safety storage cabinets
Centrifuges
CO₂ incubators
Distimatic automatic module
Documentation software
Extraction arms
Fluid aspiration systems
Heating circulators
Refrigerated / heating circulators
Incubators
Climate chambers
Laboratory freezers
Laboratory dishwashers
Laboratory refrigerators
Combined laboratory refrigerator-freezers
Laboratory chairs
Laboratory furniture
Laminar flow cabinets
Laboratory furnaces
Magnetic stirrers
Balances
Microbiological safety cabinets
Moisture analyzers
Growth chambers
Peristaltic pumps
Professional shakers
Shakers
Rotary evaporators
Overhead stirrers
Drying chambers and heating chambers
Test chambers
Ultrasonic baths
Ultrasonic cell disruptor
Ultrasonic baths
Ultra low temperature freezers
Vacuum drying chambers
Vacuum networks
Vacuum gauges and controllers
Vacuum pumps
Fume cupboards
Water baths
Water purification systems
%
Binder WIC 3 Walk-in-Chamber
The Binder Environmental Walk-in Chambers with either 6 m², 9 m² or 12 m² internal dimensions and 2,3 m height are an excellent choice for stability testing in Pharma, Food & Beverage, Cosmetics, Material Testing and many other fields of application.
In Pharma, the Binder Walk-in Chambers cover long-term and accelerated stability test conditions as specified in the ICH Q1A (R2) for new drug substances and drug products.
The walk-in chambers are designed and produced in Germany, and the temperature and environmental conditioners are made by Parameter Generation and Control in Black Mountain, NC USA. The chambers offer a wide range of features and benefits to perfectly meet requirements in stability testing.
Product features
• Long-term and accelerated stability tests according to the guidelines of ICH Q1R (R2)
• Temperature accuracy: ± 1.5°C
• Humidity range (% rH): 20...90
• Humidity accuracy: ± 2.5% RH
• High-efficiency insulation panels with a U-value of 0.21 W/m2K
• Motion sensor LED lighting
• Entire inner chamber made of stainless steel
• External service access to the conditioning unit
• Safety lockable door, which can always be opened from the inside
• Environmentally friendly refrigerant R450A
• Power supply: 230V / 50Hz, 11.5A
• Available accessories: shelving system, ramp
Compare
%
Miele A 102 upper basket
Height adjustable, for the optimum loading of inserts.
• Area of application: reprocessing laboratory glassware
• Vertical clearance 205 +/- 30 mm, width 475 mm, depth 443 mm
• With integrated spray arm
Machine affiliation: Can be used in PG 8504, PG 8583, PG 8583 CD, PG 8593 devices.
Compare
%
Bimos Labsit 4 laboratory chair
Labsit is the clever all-round solution for sitting in the most innovative environment there is: the laboratory.
• Boasting a hygienic design
• Compact dimensions
• Ergonomic construction and user comfort
• Large range of colours
• Robust and light
• Anti-bacterial upholstery
• Minimal joints and positive-locking
• Intuitive handling
• Innovative Flex functions
• Resistant to disinfectants
• Electrostatically dissipative (optional)
• Very economical
• 10 year guarantee – including on gas pressure springs
Compare
%
Bimos Unitec 3 Industrial swivel chair
Work chairs in production
• The Unitec work chair is the low-cost entry-level model for correct sitting in production environments.
• Its permanent contact backrest, a standard feature, provides staff with support when working in a seated position.
• The generous seating surfaces and backrests also ensure additional stabiliuty.
• With its selection of various covers, Unitec optically adapts to almost any working environment. This makes it a simple work chair for practically any application.
Compare
%
Liebherr SFFvh 4001 laboratory freezer
Liebherr freezers for laboratory and research use meet the highest requirements, especially in terms of safety and temperature stability.
• Integrated data logger
The integrated logger records the temperature profile, alarm history and service information for up to five years. The data can be read out directly from the appliance via the USB interface.
• Min./max. temperature log
The min./max. temperature log stores the minimum and maximum interior temperatures and shows on the display whether the storage temperatures were within the tolerance limits.
• +2 °C SafetyDevice
If the temperature falls below +2 °C due to a malfunction, the SafetyDevice takes control, stabilising the temperature, activating the alarm and protecting the contents from freezing
• Power failure alarm
If a malfunction occurs, an integrated battery provides a visual and audible alarm and takes over the power supply. As soon as the power is restored, the time of failure and the maximum temperature reached are displayed.
• LightAlarm
In the event of an uncontrolled temperature rise or other problems, the interior light of the appliance starts flashing. This visually shows when action is needed.
• Feedthrough for external sensors
An integrated opening allows a separate sensor to be connected for additional temperature monitoring without having to drill holes or break the door seal.
• Mechanical lock
Liebherr professional appliances are equipped with a mechanical lock and two keys. This ensures that unauthorised persons cannot access your valuable and sensitive stored goods.
• SmartMonitoring
The cloud-based digital solution continuously monitors and documents temperatures and alerts you immediately via email, text message or phone if any deviations occur.
• Integrated WiFi/LAN interface
The integrated WiFi/LAN interface enables you to easily connect your appliances with Liebherr SmartMonitoring or existing local systems.
• Easy-to-clean interior
The inner liner made of fully recyclable, robust and odourless polystyrene is manufactured in one piece without joints. This makes it quick and easy to clean the large, rounded corners.
• Replaceable door seal
Save time and money: the insertable Liebherr door seals are easy to change. If a seal is damaged, you can replace it yourself without any tools. Contact Liebherr Customer Service to purchase replacements.
• Self-closing door < 90°
To make loading, unloading and cleaning easier, the appliance door stays open if opened by more than 90°. If the opening angle is less than 90°, it closes automatically for safety
• NoFrost technology
Liebherr professional laboratory appliances no longer need manual defrosting. Any moisture that occurs is bound by the fan-assisted cooling, and when necessary, defrosting phases remove any remaining moisture particles from of the interior – for convenient, safe, and ice-free storage.
• ±5 °C temperature stability
Sensitive substances cannot be subjected to large deviations from the set storage temperature. Liebherr freezers guarantee a temperature fluctuation of no more than ±5 °C, so that the valuable goods you store in them are optimally protected and their quality is preserved.
• Standard compliance
The devices fully comply with the DIN 13277 standard and the IEC 61010-2-011 standard.
Compare
%
Binder M 56 drying and heating chamber with forced convection and advanced program functions
With a maximum of +300 °C and various programming options the M series material test chambers are ideal for material and aging tests. With a high air flow, the powerful fans ensure rapid heating.
BENEFITS
• Uniform drying conditions thanks to APT.line™ technology
• Identical test conditions throughout the chamber interior independent of sample size and quantity
• Outstanding thermal insulation saves operation costs
• Advanced programming options
IMPORTANT CHARACTERISTICS
Temperature range: +22°C above ambient temperature to +300°C
High temperature accuracy thanks to APT.line™ technology with increased heating output
Reinforced fan with adjustable speed
Electromechanical control of the exhaust air flap
Intuitive touchscreen controller with time-segment and real-time programming
2 chrome-plated racks
Class 2 independent adjustable temperature safety device (DIN 12880) and class 3.1 independent temperature safety device (DIN 12880) with visual/ acoustic alarm available for selection on the controller
Failsafe function – backup sensor Pt 100
Computer interface: Ethernet
Internal data logger, measured values can be read out in open format via USB
Compare
%
Binder FP 53 drying and heating chamber with forced convection and program functions
A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and particularly fast heating – even for chambers under full loads.
Product benefits
• Uniform drying conditions thanks to APT.line™ technology
• Identical test conditions throughout the chamber interior independent of sample size and quantity
• Outstanding thermal insulation saves operation costs
• Advanced programming options
Main features
• Temperature range: +10 °C above ambient temperature up to +300 °C
• High temperature accuracy thanks to APT.line™ technology
• Adjustable fan speed
• Controller with interval and real-time programming
• Electromechanical control of the exhaust air flap
• 2 chrome-plated racks
• Units up to 115 liters are stackable
• Class 2 independent adjustable temperature safety device (DIN 12880) and class 3.1 independent temperature safety device (DIN 12880) with visual/acoustic alarm available for selection on the controller
• Ergonomic handle design
• Computer interface: Ethernet
• Internal data logger, measured values can be read out in open format via USB
Compare
%
DÜPERTHAL COOL LINE Type 90 XL Standard Safety cabinet with integrated refrigerator
Safety cabinet with built-in refrigerator
• Efficient cooling: The cooling compartment has its own door for efficient and economical cooling.
• Refrigerator door is opened/closed separately
• Refrigerant: R 600a
• Maximum fire protection: Maximum safety with Type 90 technology and cooled interior.
• Interior of refrigerator explosion protected Ex II 3G, Ex nA II T6,SNCH 07, ATEX 0124 X.
• Self-closing in the event of fire: In case of fire, a thermocouple automatically initiates the uninterrupted closing of the doors. The closure control system ensures that the refrigerator is also self-closing.
• Continuous temperature control: the temperature can be adjusted continuously from +1 degrees °C to +15 degrees °C
• Constant temperatures: The integrated fan ensures stable temperatures.
• Heat energy: Heat energy is extracted via the ventilation openings and the exhaust air (connection) sockets. The air flow is monitored and if the ventilation fails, the refrigerator is automatically switched off. This is done using an ex- haust air monitoring unit for emitting warning signals, which is also available with a ventilator.
• Outer dimensions: 895 x 745 x 2080 (WxDxH) mm
• Inner dimensions: 550 x 430 x 1400 (WxDxH) mm
• Voltage: 230 V / 50 Hz
Inner fittings:
• 5 shelves made from shatterpoof glass
• 1 bottom tray: The easily removable bottom tray can be cleaned and discharged without effort.
• 1 perforated sheet insert made of powder-coated sheet steel.
Compare
%
Hei-PLATE Mix'n'Heat Expert magnetic stirrer with heating
Well-designed features for a carefree stirring and heating.
The magnetic stirrer Hei-PLATE Mix 'n' Heat Expert convinces with its intuitive handling: Thanks to respectively one display per main function (stirring and heating), you have an easily legible eye on all values and settings at any time. The handling is made via two push-and-rotary controls with LED-rings for an easy identification of the active functions. Separate timers for heating and stirring functions create flexibility and let you control your experiments better. The user-friendly menu navigation makes working with this device particularly easy.
For controlling the temperature, you can choose between three heating modes: FAST for a particularly quick heating, as well as PRECISE and PRECISE+ for a particularly exact control of your target temperature without overshoot - this is how sensitive samples are optimally protected. Therefore, the device is compatible with the temperature sensor Pt1000 as well as the double sensor Pt1000 that allows the measurement in your sample and in the bath liquid simultaneously.
For the stirring speed, there is a three-stage setting (start-up behavior). Furthermore, you can set the rotational direction of the magnetic stirring bar and benefit from the automatic stir bar detector. As a result, your sample is optimally stirred at any time, even when there are irregularities while stirring.
This magnetic stirrer is equipped with the most important safety features. The large safety distance between the heating plate and the control panel, as well as the visual residual heat indicator at temperatures > 50 °C, protect against burns.
The patented Kera-Disk® plate made of anodized aluminum is chemical-resistant, scratch-resistant and has a diameter of 145 mm (also available with 135 mm on request). This makes it suitable for the use with many accessories and samples on a small footprint. Moreover, the material used allows the fastest heating times.
Technical data
• Dimensions (w/d/h): 168 x 299 x 106 mm
• Usable Surface heating plate: 145 mm
• Weight: 3 kg
• Max. Load: 25 kg
• Drive: EC motor, counterclockwise/clockwise rotating
• Rotation speed range: 100 – 1,400 rpm
• Heating power: 800 W at 230 V (EU) 600 W at 115 V (US)
• Temperature range: 20 – 350 °C, setting accuracy 1 K
• Heating control: PID
• Temperature measurement accuracy: Operation with external temperature measuring sensor Pt1000: ± 0.2 K, plus tolerance Pt1000
• Temperature measurement resolution: 0,1 K
• Display: 2 x TFT display
• Protection class (EN 60529): IP 42
• Acoustic pressure: < 50 db(A)
• Rated Voltage: 230 V, 50/60 Hz (EU) 115 V, 50/60 Hz (US)
• Connection: L+N+PE
• Protection class IEC 60529: I
• Overvoltage Category: II
• Degree of pollution: 2
• Power input: Normal operation 230 V: 825 W (EU) / 115 V: 625 W (US) Standby mode: 1.7 W
• EMC class: B, Group 1
• Permissible ambient conditions: 5 – 31 °C at up to 80 % rel. humidity, 32 – 40 °C at up to 50 % rel. humidity (linearly reducing)
• Installation altitude: up to 2,000 m asl
Compare
%
Binder UF V 350 Ultra low temperature freezer
The BINDER ultra low temperature freezer ensures the safe storage of samples at -90 °C. It combines outstanding environmental friendliness with low energy consumption, convenient operation and an individual safety concept.
Benefits
• Lowest energy consumption in its class
• Environmentally-friendly refrigerants R-290 and R-170
• Efficient thermal insulation with vacuum insulation panels
• Rust-proof interior made completely of stainless steel
Important characteristics
• Temperature range: -90 °C to -40 °C
• Lowest energy consumption in its class
• Powerful cascade compressor cooling unit
• Environmentally friendly refrigerants R-290 and R-170
• Thermal insulation with unique long-life VIPs (vacuum insulation panels)
• Innovative door gasket concept reduces buildup of ice
• Ergonomic door handle
• Rust-proof interior made completely of stainless steel
• Detachable inner doors made of stainless steel
• 3 stainless-steel shelves providing flexible placement
• Zero-voltage alarm contact for in-house alarm system
• Internal data logger, measured values can be read out in open format via USB
• Ethernet interface
• 3 access ports, Ø 28 mm, rear
Compare
%
Bandelin SONOREX TECHNIK RM 16.2 U ultrasonic bath
High-performance ultrasonic cleaner for versatile applications
The proven and particularly robust SONOREX ultrasonic baths clean thoroughly and gently by means of intensive cavitation bubbles, even in the hard-to-reach places of the cleaning objects.
A user-friendly rotary handle control is used for easy adjustment of the cleaning time. Matching baskets, lids and cleaning and disinfection concentrates are available as accessories for optimally coordinated ultrasonic cleaning.
The SONOREX TECHNIK range currently consists of 4 series with common characteristics:
• welded stainless steel cleaning tank, 2 mm
• overflow gutter: combined with an oil separator and or a filtering system to continuously remove dirt, oils and grease floating on the surface of the tank
• cleaning fluid filling level mark, facilitates dosing
• welded drain with three-way ball valve for emptying or filling the tank and connecting a filtration system
• additional drain for connecting an oil separator and draining the overflow gutter
• heating: all models are available with (UH) or without (U) heating: on / off with control indicator, thermostatic, adjustable from 30 to 80 ° C
• case protected against drops of water in stainless steel
• for baskets, possibility of having a motorized lift with agitation function
• possibility of making sets of 2 to 5 stations with ultrasonic bath, rinsing bath, drying tank with a motorized translator / elevator / agitator
• inclined tank bottom for better cleaning results by optimal sound propagation. This facilitates the emptying of the tank and makes it possible to avoid as much as possible the accumulation of dirt and residual liquids at the bottom of the tank
• ultrasound: on / off with control indicator, timer 1 to 15 min. or continuous operation
• 40 kHz frequency generator (built-in)
Compare
%
Heidolph Hei-PLATE Sensor Advanced Package Core
Includes:
• The Hei-PLATE Mix'n'Heat Core magnetic stirrer (145 mm diameter)
• EKT Hei-Con electronic contact thermometer incl. holder
• Silicone protective cover
Technical data of Hei-PLATE Mix'n'Heat Core:
The speed and temperature are set using a scale. This magnetic stirrer is very easy to use and is equipped with the most important safety features. The large safety distance between the heating plate and the control elements, as well as the optical residual heat indicator at temperatures > 50 °C, protect against burns. A carrying aid on the underside ensures safe transport. The heating function can be activated separately and is indicated by the LED button lighting up.
• Circular scratch-resistant, chemical-resistant mixing plate with Kera-Disk coating
• Plate diameter ø: 145 mm
• Temperature range: 20 – 300 °C
• Heating power: 800 W
• Rotation speed range: 100… 1400 rpm
• Speed accuracy: ± 2 %
• Max. stirring capacity (H₂O): 20 l
• The appliance has a residual heat indication
• Maximum load: 25 kg
• Protection class IEC 60529: IP 42
Technical data of EKT Hei-Con:
• Electronic contact thermometer for measuring and regulating the medium temperature from -80 °C to 350 °C.
• With digital display
Compare
%
Nabertherm gloves, Tmax 650°C
Heat-resistant gloves for protection of the operator when loading or removing hot materials
Compare
%
Sigma 1-14 laboratory microcentrifuge Think Pink Edition
The compact Sigma 1‑14 centrifuge fits in every lab and fulfils the most stringent technical requirements. Its strong performance and large range of rotors are unique.
The microcentrifuge not only impresses with its performance data, but also supports the fight against breast cancer in the Think Pink Edition. For every device sold, Sigma donates EUR 50 to the Think Pink Europe organization in the fight against breast cancer.
Two fixed-angle rotors provide a maximum capacity of 24 x 1.5/2.0 ml. Thanks to rotors for PCR strips, microhaematocrit capillary tubes and filter tubes, the Sigma 1‑14 is an all-round laboratory centrifuge suitable for a wide variety of applications. It is popular for molecular biology applications such as DNA, RNA and protein isolation, clinical chemistry, and in research labs and food labs, universities, and the pharmaceutical industry.
What makes the Sigma 1‑14 mini centrifuge so attractive?
The handy Sigma 1‑14 mini centrifuge combines effective performance with reliability. It is pleasantly quiet even at maximum speed, has wonderfully short braking times, is easy to use, and can be closed effortlessly thanks to a motorised lid lock. Customers also appreciate the price/performance ratio.
Applications: hospitals, infant stations, Veterinary clinics, Food labs, universities & colleges, pharmaceutical labs, cell culture labs
The Sigma 1‑14 is also available as the Sigma 1‑14K refrigerated centrifuge.
Compare
%
Sigma 1-7 laboratory benchtop centrifuge
The Sigma 1‑7 is designed for the separation of blood and urine specimens in medical practices and small labs, and due to its strong performance it is also used in environmental analytics, schools and universities.
The Sigma 1‑7 compact benchtop centrifuge is especially good in delivering exact results in a very short time. With these attributes combined with convenient, intuitive operation and the motorised lid lock, which enables effortless closing of the centrifuge, it offers more than comparable devices in its segment.
What makes the Sigma 1‑7 benchtop centrifuge so attractive?
The Sigma 1‑7 benchtop centrifuge is the only one in its segment that supports up to ten saved programs. This allows routine protocols to be stored and work processes to be optimised. In operation this small centrifuge runs with especially low vibration, quietly and pleasantly.
The perfectly matched fixed-angle rotor of the Sigma 1‑7, with a maximum capacity of 6 x 15 ml, is well suited to meet the demands of small volumes of specimens. The maximum RCF of 6,153 x g and the short braking and acceleration times of this small centrifuge allow separation times to be shortened considerably.
Product options
Centrifuge & rotor package
Applications: Doctors in private practice, Veterinary practices, Small laboratory workstations, Hospitals
Compare
%
Sigma 1-14 laboratory microcentrifuge
The compact Sigma 1‑14 centrifuge fits in every lab and fulfils the most stringent technical requirements. Its strong performance and large range of rotors are unique:
Two fixed-angle rotors provide a maximum capacity of 24 x 1.5/2.0 ml. Thanks to rotors for PCR strips, microhaematocrit capillary tubes and filter tubes, the Sigma 1‑14 is an all-round laboratory centrifuge suitable for a wide variety of applications. It is popular for molecular biology applications such as DNA, RNA and protein isolation, clinical chemistry, and in research labs and food labs, universities, and the pharmaceutical industry.
What makes the Sigma 1‑14 mini centrifuge so attractive?
The handy Sigma 1‑14 mini centrifuge combines effective performance with reliability. It is pleasantly quiet even at maximum speed, has wonderfully short braking times, is easy to use, and can be closed effortlessly thanks to a motorised lid lock. Customers also appreciate the price/performance ratio.
Applications: hospitals, infant stations, Veterinary clinics, Food labs, universities & colleges, pharmaceutical labs, cell culture labs
The Sigma 1‑14 is also available as the Sigma 1‑14K refrigerated centrifuge.
Compare
%
Liebherr SRPvh 6501 heavy-duty fridge
Laboratory refrigerators and freezers are expected to provide the highest levels of safety and reliability. Precise electronic control, fan-assisted cooling, and highly efficient insulation result in outstanding energy efficiency, ensuring low operating costs and environmental protection. Advanced components and precise regulation work together to ensure optimal storage of materials.
Product Features
• Fan-assisted cooling system
• Automatic defrost
• Temperature range: -2 °C to +16 °C
Easy Operation
• Built-in handle along the full height of the door
• 2.4” color electronic control panel with touch & swipe function
• Easy-to-clean stainless steel interior lining
• Integrated, flush-mounted interior lighting (vertical, full-height side LED lighting)
Safety and Reliability
• Temperature stability up to: ±3 °C
• VCC variable speed compressor
The variable-speed compressors always provide the appropriate performance. This results in reduced energy consumption and increased temperature stability.
• Warning signal in case of malfunction: optical and acoustic
• SafetyDevice: prevents the temperature from dropping below +2 °C to avoid freezing
• PT1000 product temperature sensor
In addition to the built-in control sensor, another temperature sensor is available for measuring the simulated product temperature. The value measured by the product temperature sensor can be displayed on the screen, calibrated, and used as the reference for the device's alarm function. This ensures safer storage based on real product temperature values.
• Power failure alarm
In case of a power outage, the built-in battery maintains power for at least twelve hours and immediately activates an audible and visual alarm. Additional indication of when the power outage started and the maximum temperature reached.
• LightAlarm
In case of uncontrolled temperature rise, a door left open, or another issue, the internal lighting of the device starts to flash.
• Alarm history: Easy quality control
Logging important data from the last 10 alarms (e.g., date or maximum temperature) for the final quality assessment of stored goods.
• Built-in data logger: Trackable for years
Complete traceability independent of monitoring systems with up to 5 years of logging for temperature profiles, alarm history, and service information. Stored data can be retrieved via the USB port.
• The door automatically closes if opened at less than a 90° angle.
• Probe access: 1 x Ø 12 mm
• Electronic locking system: Protects against unauthorized access with locking/unlocking via PIN code or remote control.
• SmartLock: Automatic door locking in case of temperature alarm, only accessible by authorized personnel.
• Long lifespan
Compliance and Documentation
• DIN 13277 and IEC 61010-2-011 compliance
Liebherr laboratory and pharmaceutical refrigeration units meet all the features and performance criteria necessary for full compliance with DIN 13277. This standard defines requirements and test procedures for cooling and freezing equipment used in laboratories and for drug storage.
• Temperature distribution and consistency according to IEC 60068-3
• Safety according to IEC 61010-2-011
• Temperature setting (calibration)
• Logging of minimum/maximum temperature values
• Integrated connectivity (LAN or WiFi for BMS or SmartMonitoring systems)
Technical Data
• Gross/net volume: 614/480 L
• External dimensions (W/D/H) mm: 697/867/2135
• Internal dimensions (W/D/H) mm: 489/638/1470
• White, stainless steel exterior casing
• Door/Cover material: steel
• Adjustable shelves: 4 pcs
• Shelf material: steel with plastic coating
• Usable shelf size (W/D) mm: 480 / 638
• Shelf load capacity: 60 kg
• Door opening direction: right, reversible
• Laboratory refrigerators and freezers are expected to provide the highest levels of safety and reliability. Precise electronic control, fan-assisted cooling, and highly efficient insulation result in outstanding energy efficiency, ensuring low operating costs and environmental protection. Advanced components and precise regulation work together to ensure optimal storage of materials.
• Product Features
• Fan-assisted cooling system
• Automatic defrost
• Temperature range: -2 °C to +16 °C
• Easy Operation
• Built-in handle along the full height of the door
• 2.4” color electronic control panel with touch & swipe function
• Easy-to-clean stainless steel interior lining
• Integrated, flush-mounted interior lighting (vertical, full-height side LED lighting)
• Safety and Reliability
• Temperature stability up to: ±3 °C
• VCC variable speed compressor
• The variable-speed compressors always provide the appropriate performance. This results in reduced energy consumption and increased temperature stability.
• Warning signal in case of malfunction: optical and acoustic
• SafetyDevice: prevents the temperature from dropping below +2 °C to avoid freezing
• PT1000 product temperature sensor
• In addition to the built-in control sensor, another temperature sensor is available for measuring the simulated product temperature. The value measured by the product temperature sensor can be displayed on the screen, calibrated, and used as the reference for the device's alarm function. This ensures safer storage based on real product temperature values.
• Power failure alarm
• In case of a power outage, the built-in battery maintains power for at least twelve hours and immediately activates an audible and visual alarm. Additional indication of when the power outage started and the maximum temperature reached.
• LightAlarm
• In case of uncontrolled temperature rise, a door left open, or another issue, the internal lighting of the device starts to flash.
• Alarm history: Easy quality control
• Logging important data from the last 10 alarms (e.g., date or maximum temperature) for the final quality assessment of stored goods.
• Built-in data logger: Trackable for years
• Complete traceability independent of monitoring systems with up to 5 years of logging for temperature profiles, alarm history, and service information. Stored data can be retrieved via the USB port.
• The door automatically closes if opened at less than a 90° angle.
• Probe access: 1 x Ø 12 mm
• Electronic locking system: Protects against unauthorized access with locking/unlocking via PIN code or remote control.
• SmartLock: Automatic door locking in case of temperature alarm, only accessible by authorized personnel.
• Long lifespan
• Compliance and Documentation
• DIN 13277 and IEC 61010-2-011 compliance
• Liebherr laboratory and pharmaceutical refrigeration units meet all the features and performance criteria necessary for full compliance with DIN 13277. This standard defines requirements and test procedures for cooling and freezing equipment used in laboratories and for drug storage.
• Temperature distribution and consistency according to IEC 60068-3
• Safety according to IEC 61010-2-011
• Temperature setting (calibration)
• Logging of minimum/maximum temperature values
• Integrated connectivity (LAN or WiFi for BMS or SmartMonitoring systems)
• Technical Data
• Gross/net volume: 614/480 L
• External dimensions (W/D/H) mm: 697/867/2135
• Internal dimensions (W/D/H) mm: 489/638/1470
• White, stainless steel exterior casing
• Door/casing material: steel
• Adjustable shelves: 4 pcs
• Shelf material: steel with plastic coating
• Usable shelf size (W/D) mm: 480 / 638
• Shelf load capacity: 60 kg
• Door opening direction: right, reversible
• Castors with arrestor at the front, fixed castors at the rear
• Gross/net weight: 148/130 kg
• Annual energy consumption: 172 kWh
• Ambient temperature: +10 °C - +35 °C
• Heat emission: 305 kJ/h
• Refrigerant: R 600a
• Noise level: 60 dB(A)
• Frequency/voltage: 50/60 Hz / 220-240 V~
• Gross/net weight: 148/130 kg
• Annual energy consumption: 172 kWh
• Ambient temperature: +10 °C - +35 °C
• Heat emission: 305 kJ/h
• Refrigerant: R 600a
• Noise level: 60 dB(A)
• Frequency/voltage: 50/60 Hz / 220-240 V~
Compare
%
Heidolph Hei-TORQUE Safety Ultimate 100 Package
Each package contains a telescopic stand and a corresponding clamp to ensure ideal, ergonomic use on laboratory benches. In addition to that, we offer you two accessory parts that are meant to increase your own safety at work: the stirrer shaft guard and the beaker holder.
Included package components:
• Hei-TORQUE Ultimate 100 overhead stirrer
Speed range (rpm): 10 - 2000
Max. torque (Ncm): 100
• Telescopic stand
• Clamp
• Shaft guard
• Beaker holder
Compare
%
FVG1 vertical lab sterilizer
FVG – VERTICAL LAB STERILIZER
A COMPACT AND ERGONOMIC CHOICE.
• Applications: Bio-Pharmaceutical, Microbiology
• Loads: Sealed & unseald containers, Machine parts, Tools, Culture Media, Glassware
• Processes: Sterilization
• Useful chamber capacity: 50, 75,140 liters
FVG Vertical Lab Sterilizer combines excellent performances with overall high quality materials, simplicity of use and optimal consumption.
All FVG series autoclaves are equipped with a built-in steam generator with automatic water feed pump. These autoclaves can treat a wide range of laboratory goods with reliable sterilization technology, such as: glassware and plastic articles, unwrapped instruments, machine parts and components, porous goods, culture media and liquids in open small size containers, laboratory regular waste in open bags.
The FVG series sterilizers are suitable for the sterilization and decontamination in many different laboratory sectors as:
Private and public microbiology labs.
High schools and universities.
Research institutes.
Life science and biotech labs.
Please, click on the image “recommended kit” to check out all possible configurations referred to FVG series.
DESIGN AND TECHNICAL FEATURES
FVG series can be provided in three different chamber useful volumes: 50 liters (FVG1) – 75 liters (FVG2) – 140 liters (FVG3).
Sterilization chamber and lid are made of 316L stainless steel, with mirror polished sanitary finishing. FVG operates at high-pressure (3,5 bar g) and temperature (140°C).
Exclusive horizontal swiveling lid with pneumatic gasket “rotate-and-seal”, for improved user safety. FVG is equipped with a heat recovering system for water preheating to steam generator, assuring utilities cost saving.
FVG has TSC 09 microprocessor control system with graphic color LCD display and an exclusive dual sensor system, by pressure and temperature, for double regulation and control of the sterilization process.
KEY BENEFITS
• Ergonomically designed chamber for maximizing loadable capacity.
• Quick connections to all utilities for easy handling and installation.
• Timed free steaming with pulses for effective air removal.
• 14 free configurable automatic programs.
• Multilevel passwords protected key-users access to ensure process safety.
• Set of four castors for easy moving and installation in lab room.
• GLP compliance
COMPLIANT TO
• PED Directive 2014/68/UE – Pressure equipment
• Machine Directive Macchine 2006/42/EC
• EMC Directive 2014/35/UE
• LVD Directive 2006/95/UE
Compare
%
Nabertherm L 1/12/R7 muffle furnace
The muffle furnaces L have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.
Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type S (1200 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With flap door (L)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Solid state relays provide for lownoise operation
• R7 (1 program with 1 segment)
Option
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door