All products

%
Miele DOS K 85 flex dispenser module
Dispenser module for 5-10 litre canisters with level indicator for the automatic dispensing of liquid media.
• Dispenser monitoring – high process security as per EN ISO 15883
• For dispensing liquid cleaning agent/neutralising agent
• 352 mm siphon for 5–10 l media canisters with flexible cap
• Siphon conversion kit for 10–30 l media canisters available
%
Miele PLW 7111 SlimLine laboratory glasswasher
• Efficient – strong pump power with the variable-speed pump
• Freestanding, 1 glazed hinged door
• Number of wash levels: 3
• TouchControl control, color touch display
• Electric heating
• Loading and unloading with telescopic runners
• Electric door lock
• Usable capacity: 241 liters
• Cold water: 1
• Hot water: 1
• Steam condenser
• Multi-component filter system
%
Miele PLW 8617 D TH laboratory dishwasher
Lab washer, electrically heated- single door, with pre-heating tank, 1150 mm wide, 351 l usable capacity.
• Capacity/cycle, e.g.216 laboratory flasks, 588vials or 294pipettes
• Short cycle times thanks to pre-heated demineralised water
• Flexible and simple – modular load carriers & EasyLoad system
• Efficient – strong pump power with the variable-speed pump
• Reliable results – spray arm monitoring and conductivity meter
• Construction type: freestanding, 1 glass vertical sliding door
• Heating type: electricity
• Loading with loading carriages
• Electrical door lock
• Wash cabinet usable capacity 351 l
• Control system: PST 20
• Full-touch colour display
• Programmability: programmable
• Programmes: 30
• Free programme positions: 170
• Time left display
• Status display via chamber lighting
• Selectable display languages
• Water connection/drainage
• Cold water: 2
• Hot water: 1
• DI water: 2
• Drain pump (optional)
• Compressed air connection
• Drying unit
• Heating mode drying unit
• HEPA filter class: H13
• Filtration efficiency HEPA filter (DIN EN 1822) in %: 99,950
• External dimensions (h x w x d) (mm): 1,670x1150x990
• Net weight in kg: 395
• 2 integrated diaphragm dispenser pumps for liquid media
• Additional integrated dispenser pumps: 4
• Heated tank for pre-heating DI water
• Steam condenser (optional)
• Volumetric dispensing control
• Connection options
• Ethernet interface
• External dispenser modules
• USB interface
• Central dispensing
%
Miele A 100 upper basket
For the optimum loading of injector modules or inserts.
• Area of application: reprocessing pipettes/vials and laboratory glassware
• Upper basket with two module connections
• For holding up to 2 injector modules or inserts
• Automatic closing of the connections when not in use
• Loading height with module with plastic supports 190 mm
• Clearances: width 489, length 440 mm

Machine affiliation: Can be used in PG 8504, PG 8583, PG 8583 CD, PG 8593 devices.
%
Miele A 11/2 insert for the gentle cleaning of delicate load items by interrupting the water jet
Insert for the gentle cleaning of delicate load items by interrupting the water jet.
• With perforations 7 x 7 mm
• For use in upper and lower basket
%
Miele A 101 upper basket
Height adjustable, for the optimum loading of inserts.
• Area of application: reprocessing laboratory glassware and different utensils
• Vertical clearance 160 +/- 30 mm, width 475 mm, depth 443 mm
• With integrated spray arm

Machine affiliation: Can be used in PG 8504, PG 8583, PG 8583 CD, PG 8593 devices.
%
Miele A 12/2 insert for the gentle cleaning of delicate load items by interrupting the water jet
Insert for the gentle cleaning of delicate load items by interrupting the water jet.
• With perforations 7 x 7 mm
• For use in upper and lower basket
%
Miele A 102 upper basket
Height adjustable, for the optimum loading of inserts.
• Area of application: reprocessing laboratory glassware
• Vertical clearance 205 +/- 30 mm, width 475 mm, depth 443 mm
• With integrated spray arm

Machine affiliation: Can be used in PG 8504, PG 8583, PG 8583 CD, PG 8593 devices.
%
Miele RP 1150 base 1150mm
Base, rollable 1.150 mm wide ready, with bottom tray, floor drain. established connection without.
• Can be used for 1-door appliances with a width of 1.150 mm
• Running wheels for pulling the equipment forward, in case of servicing
• Can only be used for appliances with a drain valve
• Easy access for servicing

Machine affiliation: Can be used for PLW 8617 devices.
%
Miele APLW 000 mobile unit
Mobile unit for optimum loading of laboratory glassware on upper levels.
• Area of application: reprocessing laboratory glassware
• Equipped with 1 integrated spray arm
• For holding inserts
• Clearance: 484 x 525 mm

Machine affiliation: Can be used for PLW 6111 devices.
%
Miele ID 90 injector nozzle 2,5x90mm
Injector nozzle with plastic supports, Ø 3, length 90 mm.
• Area of application: reprocessing laboratory glassware
• Suitable for measuring flasks and test tubes, for example
• Suitable for standard mobile injector units and injector baskets

Machine affiliation: Can be used for PG 8583, PG 8583 CD, PG 8593 devices.
%
Miele CM/1 ConductivityMeter
For measuring the conductivity level and the display for changing the cartridge.
• Suitable for full demineralisation cartridges
• Optical and acoustic display for cartridge change
• 10 switch points in measuring range 0 - 199.9 µS/cm
• One-line display, connection to external LED possible
• Including wall bracket and power unit (Input: 110 - 240 V, 50/60 Hz, 85 mA)

Machine affiliation: Can be used for PG 8583, PG 8583 CD, PG 8593 devices.
%
Miele A 13 Lid
For fixing delicate wash items.
• Area of application: reprocessing laboratory glassware
• Lid in stainless steel
• 1 mm wire, 8 mm mesh size, 4 mm frames
%
Miele UG 30-60/60-85 box plinth
To raise the machine.
• 60 cm deep, 60 cm wide.
• Suitable for all machines with a width and depth of 60 cm

Machine affiliation: Can be used in PG 8504, PG 8583, PG 8593 devices.
%
Miele E 118 insert 1/1
For the optimum loading of half petri dishes.
• Suitable for 38 half petri dishes with Ø 100 mm
• Equipped with 38 holders, height 70 mm, distance approx. 26 mm
• For use in upper basket
%
Miele E 106 insert 1/2
• Area of application: reprocessing laboratory glassware and measuring cylinders
• Equipped with 10 spring hooks x 175 mm height & 16 x 105 mm height
• The distance between the spring hooks is approx. 60 mm
%
Miele A 300/2 module
For optimum loading of laboratory glassware – can be equipped with 8 nozzles.
• Area of application: reprocessing laboratory glassware
• Suitable for lab. glassware incl. Erlenmeyer and round flasks.
• Module w/o injector nozzles – equipped based on individual needs
• For up to 8 injector nozzles . Particularly suitable for nozzle diameters of 6 mm, e.g. A 840 or A 841, other diameters are possible depending on the application.
• Part of the EasyLoad system. The EasyLoad system makes reprocessing laboratory glassware considerably faster, simpler and more reliable. The biggest benefit afforded by the new system is that load items can be positioned over nozzles both more simply and faster as height adjustment of the holders is no longer necessary thanks to the smart combination of nozzles and holding frames. This makes correct positioning extremely easy.
• Nozzle spacing 118 mm across the width, 118 mm across the depth
%
Miele A 200 mobile unit
For the optimum loading of 38 pipettes.
• Area of application: reprocessing pipettes/vials
• for 10 100 ml pipettes in row 1, distance 20 mm
• for 14 25 ml pipettes in a 2nd row, distance 26 mm
• for 14 10 ml pipettes in a 3rd row, distance 26 mm

Machine affiliation: Can be used in PG 8583, PG 8583 CD, PG 8593 devices.
%
Miele A 103 upper basket
For the optimum loading of inserts.
• Area of application: reprocessing laboratory glassware, mesh trays and different utensils
• Vertical clearance: 95 mm, width 505 mm, depth 472 mm
• Particularly suitable for the reprocessing of DIN mesh trays
• Also suitable for further applications with low height items
• With integrated spray arm

Machine affiliation: Can be used in PG 8504, PG 8583, PG 8583 CD, PG 8593 devices.
%
Miele SC steam condenser PWD 86XX
Steam condenser for optimal dehumidification and cooling of the air outlet.
• Can only be used with a drying unit
• Option to connect to the on-site cooling water circuit

Machine affiliation: Can be used for PLW 8617 devices.